Specifications:
Model
Flow Rate
Volt
Current (A)
Head (m)
Cable
Outlet Dia Weight
XC-SP005
6.5L/MIN
12
2.0AMP
2.5
20cm
10mm
0.12kgs
Warning:
•
To prevent injury, always disconnect the power source when installing or servicing
any electric product.
•
Do not use the pump-to-pump gasoline oil or any flammable liquids.
•
Always make sure you use fuse amperage rated for your pump model.
•
Failure to follow these instructions may result in serious injury or fire hazards.
Optional Materials:
•
Mounting screws
•
Mounting brackets.
Pump Mounting Instructions:
Warning
: remove any polystyrene or foam blocks covering the pump around for
shipping purposes.
•
Step 1
: make sure you mount the pump wit5h safety brackets, make sure it is
holding firmly as to avoid too much vibration that will affect your seals and bearings.
•
Step 2
: now insert your hose inlet/outlet and use hose clamps to secure the pipes.
•
Step 3
: now you can link your inlet pipe to the water source and outlet to the supply,
you must always watch for the inlet/outlet arrow when installing this type of pump.
•
Step 4
: make sure your pump is at bottom of the water level as is thbe pump is not
self-priming.
•
Step 5
: make sure you pump is covered or protected from water or rains never
submerge the pump.