background image

9

Maintenance Instructions

Checking the Salt Level

Check the salt level monthly. Remove the lid from the cabinet or brine tank, make sure salt level is always above the 

brine level (you should not be able to see water).

Adding Salt

Use only clean salt labeled for water conditioner use, such as crystal, pellet, nugget, button or solar.

The use of rock salt is discouraged because it contains insoluble silt and sand which build up in the brine tank and can 

cause problems with the system’s operation.

Add the salt directly to the tank, filling no higher than the top of the brine well.

Caution

Liquid brine will irritate eyes, skin and open wounds - gently wash exposed area with fresh water. Keep children away 

from your water conditioner.

Bridging (Figure 6)

Humidity or the wrong type of salt may create a cavity between the water and the salt. 

This action, known as “bridging”, prevents the brine solution from being made, leading to 

your water supply being hard.

If you suspect salt bridging, carefully pound on the outside of the plastic brine tank 

or pour some warm water over the salt to break up the bridge. This should always 

be followed up by allowing the unit to use up any remaining salt and then thoroughly 

cleaning out the brine tank. Allow four hours to produce a brine solution, then manually 

regenerate the softener.

Care of Your Softener

To retain the attractive appearance of your new water softener, clean occasionally with 

a mild soap solution. Do not use abrasive cleaners, ammonia or solvents. Never subject 

your softener to freezing or to temperatures above 110

°

F (43°C).

Cleaning the Injector Assembly (Figure 7)

Sediment, salt and silt will restrict or clog the injector. A clean water 

supply and pure salt will prevent this from happening.
The injector assembly is located on the right side of the control valve. 

This assembly is easy to clean.
Shut off the water supply to your softener and reduce the pressure by 

opening a cold soft water faucet. Using a screwdriver, remove the two 

screws holding the injector cover to the control valve body. Carefully 

remove the assembly and disassemble as shown in Figure 7. The 

injector orifice is removed from the valve body by carefully turning 

it out with a screwdriver. Remove the injector throat the same way. 

Carefully flush all parts including the screen. Use a mild acid such 

as vinegar or Pro-Rust Out to clean the small holes in the orifice and 

throat.
Reassemble using the reverse procedure.

Resin Cleaner

An approved resin cleaner MUST be used on a regular basis if your water supply contains iron. The amount of resin 

cleaner and frequency of use is determined by the quantity of iron in your water (consult your local representative or 

follow the directions on the resin cleaner package).

INJECTOR BODY

INJECTOR THROAT

INJECTOR NOZZLE

“O” RING

INJECTOR COVER

INJECTOR SCREEN

SCREW

Figure 7

Figure 6

Summary of Contents for Econoflo EFCMINI-17SXT

Page 1: ...aintenance procedures for the continued proper operation of your unit These MUST be performed regularly for your guarantee to remain valid Econoflo MINI SXT Automatic Meter Initiated Water Softener Op...

Page 2: ...completed the valve will return to Service and resume normal operation Example Less than 6 minutes remaining in Regen Step Rapid Rinse Pushing the Extra Cycle Button during a regeneration cycle will i...

Page 3: ...in Master Programming by setting each day to either off or on The control will initiates a regeneration cycle on days that have been set to on at the specified regeneration time Control Operation Duri...

Page 4: ...lubricant may be applied to the O ring to ease installation of the riser tube DO NOT use petroleum based lubricants as they will cause swelling of O ring seals The softener or filter is now charged wi...

Page 5: ...rine refill position Wait until the water level reaches 6 in the brine tank Water can be added to the tank to speed up the filling but the valve should be in the Brine Refill position for a minimum of...

Page 6: ...ra regeneration initiated at any time Set Time of Day 1 Press and hold either the Up or Down buttons until the programming icon replaces the service icon and the parameter display reads TD 2 Adjust th...

Page 7: ...nly requires the removal of hardness but also of some iron as well Before the regeneration frequency can be set the compensated total hardness must be calculated to factor in the iron that will be rem...

Page 8: ...t display Do not attempt to troubleshoot this problem any further Regeneration must occur for the unit to recover the display to clear and the valve to function normally 7 5 To recover from Err2 the u...

Page 9: ...d be performed when little or no water will be used in the household Safety Float The brine tank is equipped with a safety float which prevents your brine tank from over filling as a result of a malfu...

Page 10: ...f Your Softener To retain the attractive appearance of your new water softener clean occasionally with a mild soap solution Do not use abrasive cleaners ammonia or solvents Never subject your softener...

Page 11: ...too large A Assure that well system has proper air eliminator control Check for dry well condition B Ensure drain line flow control is sized 6 IRON IN CONDITIONED WATER A Fouled resin bed B Iron cont...

Page 12: ...ty period shall be from the date thereof Ten Year Guarantee on Mineral Tanks and Brine Tanks WaterGroup Inc will provide a replacement mineral tank or brine tank to any original equipment purchaser in...