background image

Figure 3

Figure 1

Figure 4

Figure 2

Step 2: Connect the water supply (cold water only)

 

1. Shut off the water supply and remove the faucet hose.
2. Connect the feed water adapter and ensure that the rubber O-ring is loaded. 
• If the angle valve outlet is 3/8”, connect it to the water supply and faucet hose directly. (Figure 3)
• If the angle valve outlet is 1/2”, you need to remove the above two fittings before connection. (Figure 4)
3. Connect  one end of the 1/4" PE tubing to the inlet of the filter head. Until you reach the mark on the 
tubing.

Triple Stage Undersink Water Filtration System

WD-TSB-10 system | Installation Instructions

Filter head

Stainless faucet

Quick-connect fitting

Mark for full insert

3/8”-1/2” converter

3/8”-1/2” converter

Feed water adapter

Teflon tape

1/4” tubing

3/8" Cold water valve

1/2" Cold water valve

Note:  

The service life mentioned above is subject to chlorine reduction. Actual result varies according 

to the local water quality.

Precautions

• Do not use it with water that’s microbiologically unsafe or of unknown quality without adequate disinfection.
• For use only with cold water.
• Do not freeze the filter, as this can cause cracking and water leakage.
• Do not allow children under 3 years old to have access to small parts during installation of this product.
• This installation must comply with all applicable state and local regulations.
• Turn off the water supply while replacing the filter.

Operating temperature

Working pressure

Flow rate

Filter capacity                                   

2-38

/35-100

10-125psi (0.7-8.6bar)

1gpm                                  

Specifications

Feed water requirement

Municipal tap water

WD-10PP: up to 6 months

WD-10GC: up to 8-12 months

WD-10CT: up to 12-18 months

WARNING

Please read it carefully before installation.

Installation of the filter system

Tips: How to use the quick-connect?
To connect: 

There is an existing mark at the end of the tubing for you to confirm if the tubing is fully 

inserted into the fitting. (Figure 1)

To disconnect

Use your thumb and index finger to press down on the lock sleeve. Use your other hand to 

pull out the hose from the fitting. (Figure 2)

Note: 

Please do not pull out the tubing directly, or else it will damage the fitting and cause leakage. 

Step 1: Fix the filter head and the filter

1. Paste the assistant label to finish drilling.

Note

: Mount the water filter at least 2 inches higher

than the ground for easier filter change.
2. Install the screw and reserve enough space to hang the filter.
3. Hang the filter system on the screw.

Press

Pull

Press