![Waterdrop WD-D6-B Instruction Manual Download Page 12](http://html.mh-extra.com/html/waterdrop/wd-d6-b/wd-d6-b_instruction-manual_874889012.webp)
7
Step 3:
Install the Drain Saddle
1. Stick the foam seal on the front plate of the drain saddle. Ensure that the hole
of the foam seal is aligned with the hole of the front plate (Figure 6). Choose a
spot on the drainpipe that is convenient for installing the drain saddle.
NOTE:
It’s recommended to install the drain saddle on the vertical drainpipe.
2. Drill a 1/4" hole in the drainpipe. Be sure not to penetrate the opposite side of
the pipe.
3. Slip the front plate on one end of the tubing (without a mark) and insert the
tubing into the drilled hole for about 0.6" (Figure 7).
4.
Position the back plate on the drainpipe by tightening the screws and nuts
evenly while leaving the tubing in the hole.
5. Pop the lock clip onto the fitting to secure the connection (Figure 8).
NOTE:
In some areas, the drain tubing must be connected to the drainpipe
through the air gap. Consumers must purchase air gap accessories separately.
5.98"
15.98"
Step 4:
Position the RO System Housing
Ensure that there is sufficient space under the countertop to install the system
(15.98" *5.98" *11.97"). Set aside 2 inches of space around the system to avoid
placing the system against the cabinet.
NOTE:
Position the front panel facing toward you, which will be convenient for
future filter replacement and indicator checking. You can also adjust the placement
direction of the RO system according to the layout under the sink.
11.97"
Figure 6
Figure 7
Figure 8
Foam Seal
About 0.6"
Back Plate
Front Plate