background image

Waterco Limited ABN 62 002 070 733

www.waterco.com

WARNING

!

(646087) 04/2018

HYDROCHLOR 

MK3

mineral chlorinator

Owners Manual

This equipment must be installed and serviced by a qualified technician.
Improper installation can create electrical hazards which could result in property
damage, serious injury or death. Improper installation will void the warranty.

Offices - AustrAliA

NsW - sydNey 
(HeAd Office)
tel: +61 2 9898 8600

Qld - BrisBANe
tel: +61 7 3299 9900

Vic/tAs - MelBOurNe
tel: +61 3 9764 1211

WA - PertH
tel: +61 8 9273 1900

sA/Nt - AdelAide
tel: +61 8 8244 6000

Act distriButiON
tel: +61 2 6280 6476

Offices - OVerseAs

WAtercO (eurOPe) liMited
sittingbourne, Kent, uK
tel: +44 (0) 1795 521 733

WAtercO (usA) iNc
Augusta, Georgia, usA
tel: +1 706 793 7291

WAtercO cANAdA
longueuil, Quebec, canada
tel: +1 450 748 1421

WAtercO (NZ) liMited
Auckland, New Zealand
tel: +64 9 525 7570

WAtercO © liMited
Guangzhou, china
tel: +86 20 3222 2180

WAtercO (fAr eAst) sdN BHd
selangor, Malaysia
tel: +60 3 6145 6000

Pt WAtercO iNdONesiA
Jakarta, indonesia
tel: +62 21 4585 1481

WAtercO siNGAPOre iNtl Pte ltd
Nehsons Building, singapore
tel: +65 6344 2378

Summary of Contents for HYDROCHLOR MK3

Page 1: ...9900 VIC TAS Melbourne Tel 61 3 9764 1211 WA Perth Tel 61 8 9273 1900 SA NT Adelaide Tel 61 8 8244 6000 ACT Distribution Tel 61 2 6280 6476 OFFICES OVERSEAS Waterco Europe Limited Sittingbourne Kent UK Tel 44 0 1795 521 733 Waterco USA Inc Augusta Georgia USA Tel 1 706 793 7291 Waterco Canada Longueuil Quebec Canada Tel 1 450 748 1421 Waterco NZ Limited Auckland New Zealand Tel 64 9 525 7570 Water...

Page 2: ...ly transformed into hypochlorous acid this the chlorine form that kills algae and other harmful organism in the water A chlorine generator s main function is to produce chlorine for the pool This keeps a residual of chlorine in the pool that prevents algae and bacteria from growing The chlorine then turns back into salt and the system continues as long as the generator is functioning properly Cons...

Page 3: ...up the salt cell anode and cathode and hold an electrical potential difference between them for a designated period of time This difference is reversed after that period of time has expired and then the anode becomes the cathode and the cathode becomes the anode The reversing of polarity or electrical potential difference will then start to remove any calcium build up which may have been deposited...

Page 4: ... position see fig 1 Manual Override switch see fig 2 ON Position thetimeswitchispermanentlyONirrespectiveoftappetpositions Thisistherecommended setting to work in combination with Waterco s Aquamaster or ChemfloPlus AUTO Position the time switch is operating on timed control as determined by tappet positions This the automatic operation position OFF Position the time switch is permanently OFF irre...

Page 5: ...change the colour to indicate the correspondent situation Low Chlorine Production Level LED blinking Salt level is below the minimum allowed please add salt to pool Consult your pool professional how to increase the salt level This condition may affect the longevity of the cell and void its warranty High Chlorine Production Level LED blinking Salt level is moderately above the maximum operational ...

Page 6: ...with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety 13 The appliance is not intended for use by young children Young children should be supervised to ensure that they do not play with the appliance These chlorinators are approved and c...