Waterco Digiheat In Line Heaters

TROUBLESHOOTING

The spa pump should only be serviced by qualified service technicians. However, some problems 
can be checked and rectified by the owner before making a service call.      

FAULT

POSSIBLE CAUSE

ACTION

Display is blank

nFL

o/t

No power

Check the isolating switch is on and not 
damaged.

Blown fuse

Check the power circuit fuse or circuit breaker 
has not blown or tripped.

RCD tripped

Reset RCD.

Pump not on or pressure switch 

needs to be adjusted

Switch on pump or adjust pressure switch.

Over-Temperature Reset Switch 

tripped

See “Over-Tempture Resure Reset Switch 
tripped” below.

Water inside Digiheat reached 

45°C /113°F  

(spa water is still cold)

Check for and remove blockages in the filter and 
pipe-work. Check for blockages in the impeller 
and call for service if items are found in the 
pump/impeller. Press Over-Temperature RESET.

Over-Temperature 
Reset Switch tripped 
(touch pad power 
indicator light 
blinking) 

Water in spa reached 

45°C /113°F

(touch pad shows lower 

temperature)

Properly secure sensor in housing (refer to 
“Installing the Sensor” on page Press Over-
Temperature RESET.

Over-Temperature Sensor not 

connected or faulty

Re check Temperature Bias 
(refer to “temperature calibration”)  
Press Over-Temperature RESET.

Call service to connect or replace.

Over-Temperature 
Reset Switch tripped 
shortly after power-
up

Over temperature Sensor not 

connected.

Check sensor is connected to Control Box. 
If not, call service to connect the sensor.

Touch pad display 
shows 00

Temperature Sensor faulty.

Call for service to replace Temperature Sensor.

Water level too low

Add water to spa or pool  to operate pressure 
switch.

Heater will not 
operate

Faulty element

Call for service.

pg 09

Model

 

Weight

(kg)

Min

Flow
Rate

(lpm)

Max

Flow
Rate

(lpm)

Supply

Voltage

(volts)

frequency

(Hz)

amps

minimum

circuit

size

(amps)

IP

rating 

Max

Pressure

(kpa) @

31m head 

2.4 kW

3.5

100

350

240

50

10

15

IP23

300

3.6 kW

3.5

100

350

240

50

15

20

IP23

300

4.8 kW

3.5

100

350

240

50

20

25

IP23

300

6.0 kW

3.5

100

350

240

50

25

30

IP23

300

18.0 kW

9.5

150

450

415

50

25 /phase

30

IP23

300

24.0 kW

9.5

150

450

415

50

35 /phase

40

IP23

300

Specifications

Complies with EN60335.2.60 and AS3136/NZS6232.

WARRANTY

Waterco DigiHeats are covered by a comprehensive 12 month warranty.
Please refer to Waterco’s warranty terms and conditions.

312

469

161

594

240

267

736

273

161

332

Summary of Contents for DigiHeat 18.0kW

Page 1: ...rne Tel 61 3 9764 1211 WA Perth Tel 61 8 9273 1900 QLD Brisbane Tel 61 7 3299 9900 SA NT Adelaide Tel 61 8 8244 6000 ACT Distributor Tel 61 2 6280 6476 OFFICES OVERSEAS Waterco USA Augusta USA Tel 1 706 793 7291 Waterco Canada St Hyacinthe QC Canada Tel 1 450 796 1421 Waterco Europe Limited Sittingbourne Kent UK Tel 44 0 1795 521 733 Waterco NZ Limited Auckland New Zealand Tel 64 9 525 7570 Waterc...

Page 2: ...ng the use of the appliance by a person responsible for their safety To prevent the risk of injury or death do not permit children to use this appliance Do not allow anyone to sit in the spa or pool if the water temperature is greater than 38 C 100 F normal body temperature Hyperthermia may result In the interests of personal health it is advised persons should not to stay in the spa for more than...

Page 3: ... easier to remove and replace it To remove the front cover i remove the 6 spring loaded quarter turn locking pins first ii pull the cover gently from the top iii now slide the cover across to the left to disconnect the hinges Reverse the procedure above to ensure the cover is replaced correctly when all work is completed DigiHeat Model Volts Current Draw Minimum Circuit size 2 4 kW 240 Volts singl...

Page 4: ...e DigiHeat THE TOUCH PAD 1 Digital display Displays the water temperature bias setting and fault codes 2 On Off button Used to switch the Digiheat On or Off 3 Up arrow button Used to increase the desired water temperature and also increase the bias setting refer to bias adjustment section 4 Down arrow button Used to decrease the desired water temperature and also decrease the bias setting refer to...

Page 5: ... also referred to as the Bias adjustment setting This adjustment can only be carried out whilst the controller is set for C centigrade Example if the water in the pool or spa is 26º C and the DigiHeat control displays 24ºC To calibrate the temperature variation set the bias to 2 with the following procedure 1 Switch on both the pump and the Digiheat 2 With the use of an accurate thermometer read t...

Page 6: ... on page Press Over Temperature RESET Over Temperature Sensor not connected or faulty Re check Temperature Bias refer to temperature calibration Press Over Temperature RESET Call service to connect or replace Over Temperature Reset Switch tripped shortly after power up Over temperature Sensor not connected Check sensor is connected to Control Box If not call service to connect the sensor Touch pad...

Reviews: