INSTALLATION
digiHeat Titanium single phase models can be mounted directly onto the pipework, fixed
to a wall or base mounted. Wall and base fittings are supplied. Single phase units should be
plumbed using minimum 40mm pipe.
digiheat Titanium three phase units should be mounted securely and directly to a wall due
to the wet weight. Wall fittings are supplied with the unit. Three phase units should be
plumbed using minimum 50mm pipe.
NOTe: All units are to be mounted with a 5 degree incline to the water outlet to assist with
purging air from the unit during operation.
Direct mounting onto pipework
– simply connect the digiheat to the pipework.
ensure the pipework is rigid and secure.
Wall mounting
– use the 4 small mounting brackets supplied.
Slide two small mounting brackets into the channel
located on the top of the digiheat and the same on
the bottom.
Base mounting
– use the 2 large mounting brackets supplied
(single phase model only).
Slide two large mounting brackets into the channel
located on the bottom of the digiHeat
Large mounting
brackets
Small mounting brackets
02 I digiheat Titanium In line Spa Heaters