Waterco Commandomatic Owner'S Manual Download Page 7

Waterco Commandomatic

CONTROLLER DISPLAYS

Volumatic Display

The capacity bar graph display has been implemented to indicate the remaining capacity as a percentage of the 

bar, excluding the reserve capacity.

When the remaining capacity reaches the reserve capacity, the capacity bar graph will be blank before indicating

the  reserve  capacity.  As  the  reserve  capacity  is  depleted,  the  display  will  alternate  between  the  capacity  bar 
graph and the text “RESERVE”. Once the reserve water is being used, the unit will go into regeneration at the set 
regeneration time.
The reserve is automatically calculated by the unit to cope with demand. Its value specifies how much more water
the unit can soften before regeneration. The reserve value shown increases until it reaches the reserve limit, at 
which point the word “RESERVE” will be replaced with “OVERRUN”.

Calendar Timer Display

As the Calendar Timer is based purely on a set time and date, the capacity bar graph displaying capacity remains 

unchanged.

Regeneration/ Backwash Display

During regeneration the capacity bar graph will indicate the percentage of time to completion and will alternate 

the display between the capacity bar graph and the text “REGENERATING”.

Low Salt Warning (Softeners & Softeners / Purifiers only)

The “Low Salt” warning keeps track of the number of regeneration’s that have been performed before indicating 
“LOW SALT” on the main display. When a low salt condition occurs the main display will toggle between the 
capacity bar graph and the text “LOW SALT”. The salt should be replaced and then press the SELECT key to 
reset the low salt warning.
Sand and carbon filters do not require the “Low Salt Warning”, therefore the “Low Salt Warning”, must be set to
“0” to de-activate the low salt indicator. 

Power Loss

If power is lost to the unit for over seven days, the user settings and time settings are lost. A “POWER LOSS” 
message  will  be  shown  on  power  resuming.  The  unit  has  battery-backed  memory  for  all  service  and  user 
parameters. In the event of a power failure, the time clock in the unit will keep the correct time and all settings 
will be retained for up to seven days.

If at the time of the power failure the unit had been regenerating the resin bed, the unit will begin that cycle from

the start as soon as power is resumed to the unit.

NOTE: Even if there is one minute left in the cycle it will always start from the beginning on the resuming power.

Pull tab to activate

memory battery

REPLACING THE A10 VALVE AND CLEANING THE FILTER BED

1. Turn off the mains water inlet tap and open the drain tap to relieve the pressure.
2. Remove the two stainless steel clips and disconnect the drain line.
3. Turn the complete valve anti-clockwise for several turns until it can be lifted clear of the cylinder. The centre tube

assembly may come away with the valve. If so, place a hose back into the bed so that whilst water from the hose 

is swirling the bed material, the centre tube can be pushed back down through the bed until the top of the tube 

is level or below the top of the cylinder.

4. Re-assemble the unit, using a new “ o ” ring seal with the new valve. Place grease on the valve thread and start

the valve lightly, being careful not to cross the threads. Tighten the valve by hand –DO NOT USE EXCESSIVE FORCE.

5. If a washout is required – lay the unit on a table or support and hose the contents out of the cylinder into a large 

bucket or container. Separate the gravel if possible.

6. Wash the sand/ carbon until it is free of mud and dirt.
7. Place the unit in an upright position and replace the centre tube and screen assembly ensuring there is no gravel

left  in  the  bottom  of  the  cylinder.  Place  a  temporary  plug  in  the  top  of  the  centre  tube  then  using  a  large 

funnel;replace the cleaned gravel followed by the sand/ carbon. Remove the temporary plug. Refill with water 

and re-assemble with the valve as above.

8. Re-connect unit and backwash until clean.

ADDITIONAL DISPLAYS AND SERVICE MENUS

Access Code

Pressing the SELECT key accesses this menu, while the Main display is showing. A 4-digit access code is entered 
to set the access level required for setting various values indicated above.

NOTE: The display will always return to the main display if there is no keyboard activity for 15 seconds.

Remaining Cap 

(display only)

This displays the true remaining capacity including the reserve capacity in milligrams.

Current Usage 

(display only)

This displays the current daily use since the previous day’s regeneration/ backwash time in milligrams.

Previous Usage

 

(display only)

This displays the previous day’s usage up to the last regeneration/ backwash time in milligrams.

Average Usage

 

(can be set with access code 

8624

)

This displays the current average in milligrams, which can be adjusted.

Set Time

 

(can be set without access code)

Allows adjustment of the clock time. Note that adjustment of the minutes will reset the seconds to zero.

Calendar Override

 

(can be set with access code 

1357

)

Displays and sets the calendar override function. A value of zero disables this function.

Remaining Regens

 

(display only)

This displays the number of regeneration cycles left before indicating the warning for “LOW SALT”. Once the low 
salt warning appears, further regeneration is halted until the salt is replenished and the low salt warning is reset.

Set Regen Time

 

(can be set without access code)

 Displays and sets the time when automatic regeneration/ backwash should normally occur.

Set Reg. Period

 

(can be set without access code)

Displays and sets the duration of the regeneration/ backwash cycle in minutes.

Set Capacity

 

(can be set with access code 

8624

)

Displays and sets the capacity of unit. 50 000mg (default)

Set Hardness

 

(can be set with access code 

1357

)

Displays and sets the hardness of the water in milligrams per litre.

Set Salt Warning

 

(can be set with access code 

1357

)

Displays and sets the number of regeneration cycles, which can occur before requiring a refill of salt in the brine 
tank. Set salt warning to “0” for Sediment and Carbon Filters to de-activate the low salt warning.

Set Pulses/ Litre

 

(can be set with access code 

8624

)

Displays and sets the calibration for counting flow pulses from the flow sensor.

Flow in 1 min

 

(display only)

Displays the accumulated number of litres flowing in a one minute period. Pressing the SELECT key can restart 
the one minute period.

pg 11

Summary of Contents for Commandomatic

Page 1: ...aterco GZ Limited Guangzhou China Tel 8620 8335 1107 Waterco Far East Limited Kuala Lumpur Tel 60 3 6250 8169 PT Waterco Indonesia Jakarta Indonesia Tel 62 21 4585 1481 72515041 01 2006 www waterco com Notice to Installer This manual contains important information about the installation operation and safe use of this product Once the product has been installed this manual must be given to the owne...

Page 2: ...t is designed to cover the total range of Waterco Commandomatic domestic water softeners purifiers and filters GENERAL INFORMATION Commandomatic domestic units may be divided broadly into two types 1 Water Filters a Sediment Filters are used to remove suspended material from the water Sediment mud and algae are filtered out down to the size of approximately 10 microns by a filter bed of anthracite...

Page 3: ... protocols are strictly adhered to Excellent Performance Good Performance Fair Performance Washing machines dishwashing machines spa baths each count as one person How does a Commandomatic Sediment Carbon Filter work The filter media is held within a cylinder The filter media sits on top of a gravel bed and a centre tube passes through the media Normal service flow is down through the filter bed a...

Page 4: ...ltiple installations filters are always installed upstream of softeners CAUTION CONNECTIONS Each unit has 3 connections drain inlet and outlet These will be 15mm or 25mm depending on the model selected 1 Fit an isolation valve to the inlet supply This can be in the form of an approved gate valve or ball valve 2 Connect inlet top outlet bottom 3 Connect drain line to either the timer semi auto or t...

Page 5: ...matic HARDNESS CAPACITY W7 CAPACITY WPS4 CAPACITY S14 CAPACITY PS9 Mg L Unit Litres Litres Litres Litres 10 25 50 75 100 125 140 150 175 200 225 250 275 300 325 350 375 400 425 450 475 500 97500 39000 19500 13000 9750 7800 6964 6500 5571 4875 4333 3900 3545 3250 3000 2786 2600 2438 2294 2167 2052 1950 65000 26000 13000 8667 6500 5200 4642 4334 3714 3250 2889 2600 2364 2167 2000 1857 1733 1623 1529...

Page 6: ...he default display 3 Scroll to Set Time press SELECT and set the current time 4 Scroll to Calendar Override press SELECT and set the number of days in between regenerations This is determined by the amount of water being used and the level of hardness please refer to the Softener and Softener Purifier Regeneration 5 Scroll to Regeneration Time the default setting is at 2 00am if you wish to change...

Page 7: ... unit using a new o ring seal with the new valve Place grease on the valve thread and start the valve lightly being careful not to cross the threads Tighten the valve by hand DO NOT USE EXCESSIVE FORCE 5 If a washout is required lay the unit on a table or support and hose the contents out of the cylinder into a large bucket or container Separate the gravel if possible 6 Wash the sand carbon until ...

Page 8: ...4 S14A WPS4 WPS4A PS9 PS9A MB6 MB6A FS40 FS40A CF6 CF6A CU40 CU40A 17 Litres 17 Litres 34 Litres 34 Litres 11 Litres 11 Litres 22 Litres 22 Litres 6 Litres 6 Litres 12 Litres 12 Litres 4 Litres 4 Litres 6 Litres 6 Litres 5 Litres 5 Litres 4 Litres or 4 Litres 4 Litres or 4 Litres 6 Litres or 6 Litres 6 Litres or 6 Litres 4 Litres or 4 Litres 4 Litres or 4 Litres 6 Litres or 6 Litres 6 Litres or 6 ...

Reviews: