ENG 13
•
Installation of the Storage Tank:
First wrap teflon tape around the water nozzle (4-5 turns). Use a little bit
of silica gel to prevent water leakage and loose connections. Then,
screw in the water tank ball valve into the water nozzle and finally
connect the water pipe to the storage tank: first cut a suitable length of
the 6mm tubing, then put a screw nut on each end of the tubing. One
end of the piping should connect to the water purifier labeled storage
tank connector, the other end should go in the storage tank ball valve
(See Diagram 11). Finally place the storage tank on the floor.
Installation Notes
•
When installing the water pipes, you should not install a drain stopper.
Furthermore, the screw nut on the water pipe bottom connector should
have no wire teeth exposed.
•
If the inlet water pipe is 9mm, you should ensure that the inlet water
pipe and connector have 30-40cm of straight piping to avoid pipe
bursting accidents caused by bending of the pipe.
•
If the power cord wiring needs to be longer, extend the cord according
to the wiring requirements and use an 8mm pinched tube to wrap
around the connection. Later, wrap insulating electrical tape
on the outside surface. Do not place the cord on the floor. The cord
should be suspended in the air or should follow a path above ground.
•
During installation, make sure that there is no electrical wiring or water
pipes embedded inside the walls where you will do the drilling.
Storage Tank
Diagram 11
6mm
Screw Nut
Storage Tank Ball Valve
Water Nozzle
Base
6mm
Pipe Stopper
Adjustment Methods
Make sure that the water route connections are correct, proper power supply is used and water supply is suitable.
Then, follow these steps to adjust the purifier:
•
Open the tap water inlet valve and the water purifier inlet water ball
valve and plug the purifier in the power outlet (See Diagram 12). Close
the storage tank ball valve, then automatically start a 120 second
flushing process, water will start to drain through the discharge outlet.
•
Wait for the water purifier to operate stably (for about 5-10 minutes).
Check each connection to make sure they are secure. Check to see if
there is any leakage from the membrane shell, filters, etc.
•
Close the pure water osmosis faucet and storage tank ball valve. Wait
approximately 30 seconds. Check to see whether or not the water
purifier waste water and high pressure pump have stopped working.
•
Open the osmosis faucet. Check to see if the water is flowing through
the faucet. If not, check to see whether the tap water pressure is too low
or whether or not the high pressure switch can be reset automatically.
•
Wait until the machine is operating properly, then close the inlet water
ball valve. After a short period of time, check to see if the machine stops
working, if it does not stop working, check to see whether or not
the low-pressure switch can be reset.
•
Perform a second check to make sure everything is ok. Now your water
purifier is ready for use.
Diagram 12
Close
Inlet water valve
Open
Summary of Contents for LAL-267
Page 1: ...Innovation has a name LAL 267 Reverse Osmosis User Manual Ters Osmoz Kullanma K lavuzu...
Page 2: ......
Page 4: ...ENG 2 CONTENTS NDEK LER...
Page 20: ...TR 18...
Page 43: ...TR 41 NOTE...
Page 44: ...TR 42 NOTE...
Page 45: ...TR 43 NOTE...
Page 46: ...TR 44 NOTE...
Page 47: ......