WaterChef U9000 Use & Care Manual Download Page 9

www.waterchef.com

SETUP & INSTALLATION

7

STEP

Red Tubing

Compression Nut

Compression Nut

3/8” T-Valve

Cold Water    

Supply Line

Cold Water    

Supply Line

Red Tubing 

(

from 3/8” T-Valve)

Red Inlet Connector

Blue Outlet Connector

  1. Locate an area under the kitchen sink to place the Base. Base should  

   be located directly under area where the Faucet will be installed.
 2. Using the open ended wrench, unthread the compression nut  

   located on top of the shut-off valve located on existing cold water  

   supply line. 

(fig. L)

 3. Thread the 3/8” T-Valve onto cold water supply line, and tighten  

   with the open ended wrench. 

(fig. M, Step 1)

 Next, thread the  

   compression nut onto the top of T-Valve and tighten. 

(fig. M, Step 2)

  

   Lastly, press the Red Tubing into the Outlet Connector located  

   on the T-Valve. 

(fig. M, Step 3)

 

 4. Press opposite end of Red Tubing into Red Inlet Connector located  

   on top of Lid Assembly. 

(fig. N)  

Then press Blue Tubing into  

   Blue Outlet Connector. 

(fig. O)

 5. Locate an area on cabinet wall to mount the Intelligent Monitor

.  

   Secure Intelligent Monitor

 to the wall using the Velcro Adhesive  

   Strips provided. 

(fig. P)

(continued on following page)

Blue Tubing

Velcro Strip 

(on cabinet wall)

Intelligent 

Monitor

System Installation:

IMPORTANT

Before attempting this installation, be certain to turn “OFF” the cold water supply  

located under your sink. If a shut-off valve is not located on the cold water line directly 

under your kitchen sink, shut off the main water supply to your home.

RECOMMENDATION

You may want to reduce the length of the Tubing if you find there is excess. However, 

it is advisable to leave the Red and Blue Tubing long enough so that the System can 

be easily removed from under the sink for Filter Cartridge replacement.

CAUTION

Use a sharp knife when cutting Tubing. Take extra care not to distort Tubing while  

cutting. Cut Tubing end straight. Failure to do so may result in leaking.

L

M

3

STEP

2

STEP

1

N

O

P

IMPORTANT

Once inserted completely, give Tubing a gentle tug to make sure it has been properly 

seated in the fitting to create a permanent seal. If you find that it is necessary to 

remove the Tubing from Inlet or Outlet Connectors, depress the small Collar located 

on the Inlet and Outlet Connectors and pull Tubing upward at same time.

Summary of Contents for U9000

Page 1: ...sted and Certified by NSF International against NSF ANSI Standard 42 for the reduction of Chloramine Chlorine Taste and Odor and nominal Particulate Class I and NSF ANSI Standard 53 for the reduction...

Page 2: ...tion 13 Notes 13 Designer Faucet 3 8 T Valve Included Literature Installation Use Care Guide Performance Data Sheet Product Registration Card LED Faucet Ring Spacer Wing Nut INTELLIGENT MONITOR COMPON...

Page 3: ...ue to perform as tested and represented be sure to use only genuine NSF certified WaterChef UR90 Filter Cartridges 8 Do not allow System to sit for extended lengths of time without being used 10 days...

Page 4: ...ery Shuttle includes Battery 7 9 904 0100 Spacer Wing Nut 8 3 212 0015 3 8 T Valve 9 UR90 Filter Cartridge includes Battery and Shuttle 10 4 600 0017 Blue Tubing 5 ft 11 4 600 0015 Red Tubing 5 ft 12...

Page 5: ...s required for most under counter installations Drilling a Hole in a PORCELAIN CERAMIC Sink fig A 3 8 Electric Drill 5 8 Carbide Masonry Drill Bit 5 8 High Speed Drill Bit Hammer Punch Masking Tape Dr...

Page 6: ...bit fig F Proceed to Faucet Installation instructions on page 6 5 8 Masonry Drill Bit 5 8 High Speed Drill Bit Sink Cross Section Sink Cross Section Porcelain Ceramic Layer Porcelain Ceramic Layer Me...

Page 7: ...ons on page 6 1 8 High Speed Drill Bit 5 8 High Speed Drill Bit Steel Sink Cross Section Steel Sink Cross Section NOTE If your sink has another hole that currently has a spray attachment you may decid...

Page 8: ...ea of the Spacer hole and guide Spacer onto Faucet Stem Thread Wing Nut onto Faucet Stem and hand tighten fig K Faucet Stem Blue Tubing Spacer Wing Nut LED Faucet Ring Cable Cable Cable Notch Sink Cro...

Page 9: ...igent Monitor to the wall using the Velcro Adhesive Strips provided fig P continued on following page Blue Tubing Velcro Strip on cabinet wall Intelligent Monitor System Installation IMPORTANT Before...

Page 10: ...in a loss of data 9 Slowly turn your cold water supply ON and check for leaks 10 Turn System Faucet ON Water will begin to fill the Filter Housing Once water begins to flow from the System Faucet the...

Page 11: ...onto the Threaded Post inside Lid Assembly until you feel resistance Make an additional quarter turn Do NOT over tighten fig W continued on following page Used Filter Cartridge Gloves RECOMMENDATION R...

Page 12: ...is time to replace the Filter Cartridge Removing Battery Shuttle prematurely may result in a loss of data 10 Slowly turn your cold water supply ON and check for leaks 11 Turn System Faucet ON Water wi...

Page 13: ...e MUST be replaced at time of Cartridge replacement Included with UR90 Filter Cartridge CONDITION Ice cubes appear cloudy in the center REASON Minerals such as calcium and magnesium that are present i...

Page 14: ...press or implied warranty Except to the extent prohibited by applicable law any implied warranty or merchantability or fitness for a particular purpose is limited in duration to the duration of the ab...

Page 15: ...you may complete and return this registration form to WaterChef Customer Care 3760 Barron Way Reno NV 89511 NAME STREET ADDRESS CITY STATE ZIP PHONE EMAIL MODEL U9000 SERIAL DATE OF PURCHASE PURCHASED...

Page 16: ...R 15 01 1 404 0090 WaterChef 3760 Barron Way Reno NV 89511 tel 800 879 8909 int l 1 775 359 9500 www waterchef com Manufactured by Water Safety Corporation...