IntrodUCtIon

Congratulations on the purchase of your new WaterChef

®

 Premium Filtration system!

You have taken an important step toward improving the quality of your drinking and cooking 
water. This System only takes a few minutes to install in your home, office, cabin, RV or 
dorm room.

WaterChef Premium Filtration Systems are crafted using only the finest materials and  
workmanship, and will serve you reliably for many years to come when operated and maintained 
according to the directions contained in this guide. You have made a wise investment in  
providing quality water for you and your loved ones. Now please take a few minutes to learn 
about all the features and benefits your new System has to offer!

  1. Replacement Cartridges may be purchased from a WaterChef reseller. For the location  
    of the reseller nearest you, or for additional purchase information, contact WaterChef  
    Customer Care at 

1.800.879.8909

.

  2. The actual capacity of your Cartridge may vary from the rated capacity. This may be due  
    to the volume of contaminants or sediment actually present in your water supply. 
    Replace the Cartridge: 
      - Annually
      - When the flow rate diminishes 
      - When the rated capacity of the Cartridge has been reached
      - When you notice a taste or odor re-occurrence
      - When the Intelligent Monitor begins blinking RED

  3. Read this manual completely before attempting to install or use this product.

  4. Do not use water that is microbiologically unsafe or of unknown quality without  
    adequate disinfection before or after the System.

  5. Individuals requiring specific microbiological purity should consult their physician. 

  6. For use on cold potable water supplies only. 

  7. For this System to continue to perform as tested and represented, be sure to use only  
    genuine, NSF certified WaterChef

®

 Replacement Cartridges (CR70).

  8. Do not allow System to sit for extended lengths of time without being used (10 days or  
    more). If System must be left unused for more than 10 days, drain all water from the  
    System and remove the Cartridge. Once you return, re-install Cartridge and flush for  
    15 min. prior to use. 

(The flushed water can be used to water plants.)

  9. Installation of this product must comply with all state and local laws and regulations.  
    Refer to your local agencies for details.

 10. The contaminants or other substances removed or reduced by this System may not be  
    in all users’ water.

IMPortant Use GUIdelInes

Summary of Contents for Countertop C7000

Page 1: ...ystem MADE IN USA MADE IN USA Questions 1 800 879 8909 MON FRI 8 AM 5 PM PST Read and Save these Instructions Important System Tested and Certified by NSF International against NSF ANSI Standard 42 fo...

Page 2: ...ing 7 Warranty 8 Warranty Registration 9 Lid and Housing Assembly 3 Piece Faucet Adapter Kit includes 3 washers Battery Shuttle includes Battery Included Literature Installation Use Care Guide Perform...

Page 3: ...pply Replace the Cartridge Annually When the flow rate diminishes When the rated capacity of the Cartridge has been reached When you notice a taste or odor re occurrence When the Intelligent Monitor b...

Page 4: ...aterChef Countertop Filtration System Model C7000 3 2 4 6 1 5 Item Part Description 1 1215 55 05 Lid Assembly White 1 1215 41 01 Lid Assembly Black 2 4 104 0052 02 Battery Shuttle White includes Batte...

Page 5: ...an your kitchen faucet In this case use the adapter with internal threads and thread it directly to your kitchen faucet Next thread the Diverter Valve to the Adapter fig D 7 If your kitchen faucet has...

Page 6: ...e times and will then start blinking green This resets the rated capacity counter to zero gallons Do not remove Battery Shuttle until it is time to replace Cartridge Removing Battery Shuttle premature...

Page 7: ...emain attached to the Lid Assembly fig K 2 Hold the Lid Assembly and rotate the Cartridge counterclockwise to remove Discard the old Cartridge with your regular refuse fig L 3 Wash the inside of Filte...

Page 8: ...l tightened fig O Step 2 6 A new Battery is included with your replacement Cartridge Insert new Battery into Battery Shuttle and insert into Lid Assembly fig P The Intelligent Monitor will flash green...

Page 9: ...ed Cartridge and Battery Condition Diverter Pin is sluggish or does not fully return to the off position after being in service for a while Reason 1 There could be a lack of lubricant on the shaft of...

Page 10: ...breach of any express or implied warranty Except to the extent prohibited by applicable law any implied warranty or merchantability or fitness for a particular purpose is limited in duration to the du...

Page 11: ...y complete this form and return to WaterChef Customer Care 3760 Barron Way Reno NV 89511 Name Street Address City State Zip Phone email Date of Purchase Model C7000 Serial Purchased From Send me Annua...

Page 12: ...3760 Barron Way Reno NV 89511 tel 800 879 8909 int l 1 775 359 9500 email info waterchef com www waterchef com Manufactured by Water Safety Corporation R 11 07 1 404 0094...

Reviews: