background image

Step 3:  Power Pac Installation and Start-up:

Open the Power Pac and remove the packing material and charger.

Remove the switch cover (protects during shipment) and flip the switch “OFF” (down).

Remove the battery terminal cover and attach the loose wire to the now-exposed terminal.

Slide the bracket of the Power Pac over the bracket at the rear of the Dolly.

Fill tank to desired level and flip the switch to the ‘ON’ position.  The pump will run for a few seconds while the 
manifolds pressurize, then it will turn off.  Check for leaks.  The most common cause of leaks is an improperly 
seated hose.  To prevent an unwanted drenching, 

TURN OFF THE PUMP 

before disconnecting 

ANY

hoses, then 

re-seat the hose.

Assembly Instructions for the 

Gen2 Vertical Power Model

Page two