background image

 

01/2015 

 

 

 

VERSAX-6/9 Quick

 

Guide  

This Quick Guide shows the basic operation of the 

WATERAX

 VERSAX-6/9 2-stage self-priming pump.  

  The 

WATERAX

 VERSAX-6/9 pairs a 

WATERAX

 self-

priming 2-stage pump end with a Honda GX200 or 
GX270 gasoline engine. For instructions regarding the 
engine, as well as for oil and fuel recommendations, 
please refer to the engine manufacturer’s manual. 

  For detailed instructions on using and troubleshooting 

your pump, as well as full service and maintenance 
instructions, refer to our website to download the 

VERSAX Owner’s Manual

  For full specifications and performance curves, see the 

VERSAX Data Sheet

 

Warnings and Safety Precautions

 

This  warning  label  appears  on  all 

WATERAX

  pumps  to  identify  safety 

hazards as follows: 

 

READ YOUR ENGINE MANUAL!   

 

Before proceeding further, locate and read the engine 
manufacturer’s manual. It contains very important safety 
information that 

MUST

 be read, understood and followed to 

safeguard you and your equipment from harm, as well as for 
the proper use and care of your engine. Use only fuel and 
oil type recommended in the engine manufacturer’s manual. 
Always check oil level in crankcase before use.  

WEAR EAR AND EYE PROTECTION.   

 

Always wear eye and ear protection when operating the 
pump unit. Sound level of the unit: 92 dB(A). 

GENERAL WARNINGS: 

 

 

Do not operate if mentally or physically fatigued. 

 

Inspect hoses and piping to avoid burst injuries. 

 

No modifications and/or alterations may be made to the 
pump. Any such modifications void the pump warranty 
and can endanger pump operators. 

 

Do not operate the pump above the maximum rated 
pressure. Use only pipe, hose, and fittings rated at or 
above the maximum pressure rating of the pump or 
system design.  

 

Slowly close valves. Use slow close valves wherever 
possible to safeguard operators and prevent damage 
from water hammer. 

 

Dry weight of the unit: 57-84 lbs (weight varies 
according to options). 

READ THE PUMP OWNER’S MANUAL! 

 

The improper use of this pump could result in serious injuries 
as well as damage to the unit. Read the 

VERSAX Owner’s 

Manual

 before using your VERSAX pump unit and follow the 

safety instructions in this Quick Guide.  

NEVER RUN THE ENGINE IN A CLOSED 
OR CONFINED AREA

.

 Exhaust gas contains 

carbon monoxide which is poisonous to humans. 
Avoid inhalation of exhaust gas.

  

REFUEL ENGINE WITH CARE

. Gasoline is 

extremely flammable, and gasoline vapor can 
explode. Refuel in a well-ventilated area, with the 
engine stopped. 

NEVER TOUCH ANY EXHAUST SYSTEM 
PARTS WHILE ENGINE IS RUNNING

. Always 

allow enough time, after stopping the unit, for proper 
cooling of these parts and surrounding areas.  

 

EQUIPMENT DAMAGE PREVENTION: 

  Flush the pump with fresh water if the pump has been 

used to pump salty, brackish, high mineral content 
water, water containing debris, or foam injected water. 
Check that debris is cleared before using the pump 
again. 

  Always draft water using a suction hose strainer.

 

 

Plumbing installed on a fixed pump MUST be self-
supported. 

Reviews: