background image

RANCHER Quick Guide 

 

09/2019 

 

 

5.  Connect discharge hose, nozzles, etc., 

to pump, and 

tighten firmly with coupling wrench.

 

6.  Start the engine. 

a.  Open fuel valve. 
b.  Close/engage choke, if engine is cold.  
c.  Increase throttle past the idle position. 
d.  Position the ignition switch to the ON position. 
e.  Close all discharge and recirculation valves. 
f. 

Give starter rope a quick and steady pull until engine 
starts. 

g.  Open/disengage choke. 
h.  Slightly open the recirculation valve. Water should be 

recirculating back into the tank. If there is no water 
recirculating, the pump has not been fully primed. 
Re-prime the pump. 

i. 

Allow the engine to warm up for at least 2 minutes 
before using full throttle. 

 

 

 

7.  Discharge water. 

Once the pump is primed, and with the engine running, 
you can begin to discharge water.  

a.  Slowly open the discharge valve.  

 

To use the hose reel, slowly open the Reel valve 
and close the Overboard discharge and 
Recirculation valves.  

 

To use the overboard discharge, slowly open the 
Overboard discharge valve and close the Reel 
and Recirculation valves. 

b.  Adjust the pump performance by throttling the engine 

up or down, or opening or closing discharge valve at 
various positions, or any combination of the two.  

!

  

DO NOT

 leave the pump running with all the 

discharge valves closed for more than one minute, 
or else the pump may overheat and become 
damaged. To avoid this, open the recirculation valve 
to allow fresh water to continue to enter the pump. 

!

  

DO NOT

 open the recirculation valve if the foam 

eductor is in function to avoid pumping foam in the 
tank. If this occurs, it is recommended to flush out 
the tank with fresh water.

 

8.  Apply foam (if applicable, and if equipped with the 

optional Scotty Around the Pump foam eductor). 

a.  Ensure that the recirculation valve is 

closed

 when 

using foam. 

b.  Open the Scotty foam eductor valve to the desired 

eduction ratio. 

c.  Select the water discharge method. You can either 

discharge water through the hose reel or through the 
discharge valve. 

d.  When you are done using the foam, be sure to flush 

the system thoroughly for at least 2 minutes. To flush 
the Scotty foam eductor, close the eductor valve and 
circulate fresh water through the eductor. 

Optional Foam System

Scotty foam 

eductor 

valve

 

 

 

 

Summary of Contents for RANCHER Series

Page 1: ...ly fatigued Inspect hoses and piping to avoid burst injuries No modifications and or alterations may be made to the pump Any such modifications void the pump warranty and can endanger pump operators Do not operate the pump above the maximum rated pressure Use only pipe hose and fittings rated at or above the maximum pressure rating of the pump or system design Slowly close valves Use slow close va...

Page 2: ...evel see engine manual 3 Select the suction mode Position the 3 way valve to the desired suction port If using the overboard suction connect the suction hose and footvalve strainer Use a universal hose coupling wrench to tighten coupling firmly If the RANCHER unit is equipped with a foam eductor system close the foam eductor valve prior to engine start by turning the adjustment knob counter clockw...

Page 3: ...ose the Reel and Recirculation valves b Adjust the pump performance by throttling the engine up or down or opening or closing discharge valve at various positions or any combination of the two DO NOT leave the pump running with all the discharge valves closed for more than one minute or else the pump may overheat and become damaged To avoid this open the recirculation valve to allow fresh water to...

Page 4: ...own check all fluid levels and add as needed i Completely drain the pump of all water j Break down and store all equipment as outlined by the apparatus or department procedures k Visually inspect the pump end Clean any dirt or debris from the pump unit If necessary a mild soap and water solution can be used Note and report any performance irregularities or any abnormal mechanical sounds l Close al...

Reviews: