Convertible Jet Pumps
Models DCJ500 (#6330) & DCJ750 (#6331)
Operating & Installation Instructions
Please read these instructions carefully. Failure to comply with instructions and designed operation of this system may void
the warranty.Your pump has been carefully packaged at the factory to prevent damage during shipping. However, occasional damage
may occur due to rough handling. Carefully inspect your pump for damage that could cause failure. Report any damage to
your carrier or your point of purchase.This pump is designed for shallow well installation for water level up to 25 feet, with injector installed on pump body; or for
deep well installation for water level up to 80 feet, with 1-1/4” pipes and injector down in the well. A pressure switch and
pressure gauge are standard features. The pump starts when the pressure drops to a cut-in setting (30 psi) and cut-out
setting (50 psi). The DuroJet Convertible Jet Pump can be mounted to either a pre-charged horizontal pressure tank or used
with a pre-charged free standing pressure tank. The pumps can also be used with conventional air to water tanks. For deep
well applications, replace the short tube in the ejector assembly to long tube #302922 (sold separately).NOTE: Pre-assembled pump and pre-charged pressure tank packages are also available.
#54806EF Rev. 4/11
Dual Jet
CLICK ANYWHERE on THIS PAGE to RETURN to WATER & WELL PUMP MANUALS & INFORMATION atInspectApedia.com
Page 1: ...pump body or for deep well installation for water level up to 80 feet with 1 1 4 pipes and injector down in the well A pressure switch and pressure gauge are standard features The pump starts when th...
Page 2: ...and void the warranty 10 Do not run the pump dry or damage will occur 11 The unit should be connected to a grounded circuit equipped with a ground fault interrupter device 12 Before installing the pu...
Page 3: ...setting is 30 psi cut in and 50 psi cut out Wells A new well should be pumped clear of sand before installing the pump Sand will damage the pumping parts and seal The drawdown level of the well shoul...
Page 4: ...ating Driven Well or Sandpoint Well 1 Drive the point several feet below the water table Note A packer type foot valve can be installed in the well This type of foot valve allows the well to be filled...
Page 5: ...down in the well This pump is designed for pumping potable water in applications where the water level is up to 80 feet Drilled Well 1 Assemble the foot valve to the ejector The short tube in the eje...
Page 6: ...d The pump should be connected to a separate electrical circuit directly for the main electrical service panel Do not use an extension cord 4 It is mandatory that a permanent ground connection be made...
Page 7: ...oJet Convertible Deep Well Jet Pumps When using DuroJet pumps on deep well applications longer tube for ejector assembly is required WaterGroup s part number for the long tube is 302922 1 Remove prime...
Page 8: ...pen a faucet nearest the tank and allow all water to drain from the tank 2 Measure the tank precharge at the valve stem using a tire gauge 3 If necessary adjust the precharge with an air pump to 2 PSI...
Page 9: ...750 1 10 302911 PLUG DRAIN PRIME DCJ500 750 1 4 18NPT 2 11 302912 O RING DIFFUSER DCJ500 750 OD 34 5 3 5 1 12 302913 O RING HOUSING DCJ500 750 OD 154 5 3 5 1 13 302914 ADAPTER PRESSURE SWITCH DCJ500 7...
Page 10: ...12 2 6 1 0 5 60 0 15 17 3 11 8 5 9 0 5 60 0 16 16 5 11 4 5 7 0 4 60 0 18 15 2 11 1 5 5 0 1 60 0 20 14 7 10 5 5 1 57 0 22 13 4 9 8 4 9 55 0 24 12 9 9 3 4 5 53 0 25 11 5 8 1 4 4 53 0 26 11 1 7 9 4 1 28...
Page 11: ...and impeller b Check water level in well to see actual pumping level Measure vertical distance to pump and compare to tolerance for pump type c See No 2c above d Compare minimum pressure on which capa...
Page 12: ...ill be made or a replacement pump or part will be supplied free of charge The serial number of the pump must be supplied This warranty does not obligate the manufacturer to bear the cost of field labo...