background image

Convertible Jet Pumps

Models DCJ500 (#6330) & DCJ750 (#6331) 

Operating & Installation Instructions

Please read these instructions carefully. Failure to comply with instructions and designed operation of this system may void 

the warranty.
Your pump has been carefully packaged at the factory to prevent damage during shipping. However, occasional damage 

may occur due to rough handling. Carefully inspect your pump for damage that could cause failure. Report any damage to 

your carrier or your point of purchase.
This pump is designed for shallow well installation for water level up to 25 feet, with injector installed on pump body; or for 

deep well installation for water level up to 80 feet, with 1-1/4” pipes and injector down in the well. A pressure switch and 

pressure gauge are standard features. The pump starts when the pressure drops to a cut-in setting (30 psi) and cut-out 

setting (50 psi). The DuroJet Convertible Jet Pump can be mounted to either a pre-charged horizontal pressure tank or used 

with a pre-charged free standing pressure tank. The pumps can also be used with conventional air to water tanks. For deep 

well applications, replace the short tube in the ejector assembly to long tube #302922 (sold separately).
NOTE: Pre-assembled pump and pre-charged pressure tank packages are also available.

#54806EF   Rev. 4/11

Dual Jet

CLICK ANYWHERE on THIS PAGE to RETURN to WATER & WELL PUMP MANUALS & INFORMATION at
InspectApedia.com

Summary of Contents for 6330

Page 1: ...n pump body or for deep well installation for water level up to 80 feet with 1 1 4 pipes and injector down in the well A pressure switch and pressure gauge are standard features The pump starts when the pressure drops to a cut in setting 30 psi and cut out setting 50 psi The DuroJet Convertible Jet Pump can be mounted to either a pre charged horizontal pressure tank or used with a pre charged free...

Page 2: ...e and void the warranty 10 Do not run the pump dry or damage will occur 11 The unit should be connected to a grounded circuit equipped with a ground fault interrupter device 12 Before installing the pump have the electrical outlet checked by a licensed or certified electrician to make sure the outlet is properly grounded 13 Make sure the line voltage and frequency of electrical current supply agre...

Page 3: ...h setting is 30 psi cut in and 50 psi cut out Wells A new well should be pumped clear of sand before installing the pump Sand will damage the pumping parts and seal The drawdown level of the well should not exceed the maximum rated depth for the pump The capacity of the pump will be reduced and a loss of prime may occur Location Select a location as close to the water supply as possible Be sure to...

Page 4: ...rating Driven Well or Sandpoint Well 1 Drive the point several feet below the water table Note A packer type foot valve can be installed in the well This type of foot valve allows the well to be filled with water when priming and makes the inlet pipe much easier to test for leaks Follow the manufacturer s instructions when installing the packer type foot valve As an alternative an in line check va...

Page 5: ...s down in the well This pump is designed for pumping potable water in applications where the water level is up to 80 feet Drilled Well 1 Assemble the foot valve to the ejector The short tube in the ejector assembly needs to be replaced with long tube 302922 2 Connect suction pipe and drive line to the ejector as shown in the diagram on the following page 3 Install the assembly so foot valve is sub...

Page 6: ...ed The pump should be connected to a separate electrical circuit directly for the main electrical service panel Do not use an extension cord 4 It is mandatory that a permanent ground connection be made from the pump motor to the grounding bar at the service panel Do not connect the pump motor to a power supply until the pump is permanently grounded The ground wire should be copper and at least as ...

Page 7: ...roJet Convertible Deep Well Jet Pumps When using DuroJet pumps on deep well applications longer tube for ejector assembly is required WaterGroup s part number for the long tube is 302922 1 Remove prime plug from the pump discharge 2 Fill pump and piping completely full of cold water 3 Replace the prime plug 4 Make sure that the long tube is replaced with short tube in the ejector assembly 5 Start ...

Page 8: ...Open a faucet nearest the tank and allow all water to drain from the tank 2 Measure the tank precharge at the valve stem using a tire gauge 3 If necessary adjust the precharge with an air pump to 2 PSI below the cut in pressure of the pump Lubrication The bearings used in the pumps are lifetime lubricated at the factory and require no additional lubrication Diagnosing Waterlogged Tanks Conventiona...

Page 9: ...J750 1 10 302911 PLUG DRAIN PRIME DCJ500 750 1 4 18NPT 2 11 302912 O RING DIFFUSER DCJ500 750 OD 34 5 3 5 1 12 302913 O RING HOUSING DCJ500 750 OD 154 5 3 5 1 13 302914 ADAPTER PRESSURE SWITCH DCJ500 750 1 14 302915 NUT ADAPTER PRESSURE SWITCH DCJ500 750 1 15 302916 ADAPTER PRESSURE TUBE DCJ500 750 1 4 18NPT 1 16 302917 PRESSURE SWITCH DCJ500 750 1 17 302918 MECHANICAL SEAL DCJ500 750 1 19 302920 ...

Page 10: ... 12 2 6 1 0 5 60 0 15 17 3 11 8 5 9 0 5 60 0 16 16 5 11 4 5 7 0 4 60 0 18 15 2 11 1 5 5 0 1 60 0 20 14 7 10 5 5 1 57 0 22 13 4 9 8 4 9 55 0 24 12 9 9 3 4 5 53 0 25 11 5 8 1 4 4 53 0 26 11 1 7 9 4 1 28 10 9 7 6 3 8 30 10 7 6 9 3 7 3 4 HP Jet Pump Lift in Feet 30 40 50 60 70 80 Capacity in USGPM at 20 psi 6 6 6 5 4 3 Capacity in USGPM at 30 psi 6 6 5 4 3 2 Capacity in USGPM at 40 psi 5 4 3 2 1 Capac...

Page 11: ... and impeller b Check water level in well to see actual pumping level Measure vertical distance to pump and compare to tolerance for pump type c See No 2c above d Compare minimum pressure on which capacity is based with operating pressure shown on gauge e Replace suction and drive lines with larger diameter pipe f Inspect for wear on impeller nose or internal blockage a Nozzle or impeller clogged ...

Page 12: ...will be made or a replacement pump or part will be supplied free of charge The serial number of the pump must be supplied This warranty does not obligate the manufacturer to bear the cost of field labor or transportation in connection with the replacement or repair of defective parts or units nor shall it apply to any product upon which repairs or alterations have been made unless authorized by th...