13.  Watch for any leaks in the system. 

Turn  the  power  back  on.  The 

pump  will  start  and  fill  the  tank. 

Turn on a faucet as far above the 

pump as possible. This will let air 

leave  the  system  as  it  fills  with 

water.  As  soon  as  water  comes 

out of the faucet you just turned 

on,  turn  it  off.  The  pump  will 

now build pressure in the system 

until  that  pressure  reaches  the 

pump  cut-out  setting.  If  you 

see  a  leak,  turn  off  the  power 

immediately and tighten or re-do 

the connection that is leaking. It should take 30 seconds to 1 

minute for the pump to prime. 

If  the  pump  does  not  fill  the  tank,  turn  the  system  off  and  

check  the  manufacturer’s  instructions  for  priming  the  pump. 

Turn  on  a  faucet  nearby  to  see  that  the  system  is  operating 

properly. 

IMPORTANT

Safety Instructions • Be sure to read.

This  tank  is  designed  for  use  with  potable 

water,  limited  to  a  maximum  pressure  of  100 

psi and a maximum working temperature of 130°F. Please note: a 

hot water heater or a boiler in a hydronic heating system will heat 

water hotter than 130°F routinely. Use a thermal expansion tank 

for  hot  water  overflow  from  a  hot  water  heater,  or  use  an 

expansion  tank  for  hot  water  overflow  in  a  hydronic  heating 

system.  See  the  owner’s  manual  for  your  pump  for  output 

information.

EXPLOSION  OR  RUPTURE  HAZARD

  A  relief 

valve must be installed to prevent pressure in 

excess of local code requirement or maximum working pressure 

designated  in  the  Product  Manual,  whichever  is  less.    Do  not 

expose  Product  to  freezing  temperatures  or  temperatures  in 

excess of 200° F.  Do not adjust the pre-charge or re-pressure this 

Product except for any adjustments required at the time of initial 

installation,  especially  if  Product  corroded,  damaged  or  with 

diminished integrity.  Adjustments to pre-charge must be done at 

ambient temperature only.  Failure to properly size the Product or 

follow  these  instructions  may  result  in  excessive  strain  on  the 

system  lead  to  Product  failure,  serious  or  fatal  personal  injury, 

leakage and/or property damage.

This  Product,  like  most  Products  under 

pressure, may over time corrode. Weaken and 

burst  or  explode,  causing  serious  or  fatal  injury,  leaking  or 

flooding  and/or  property  damage.    To  minimize  risk,  a  licensed 

professional must install and periodically inspect and service the 

Product.    A  drip  pan  connected  to  an  adequate  drain  must  be 

installed if leaking or flooding could cause property damage.  Do 

not  locate  in  an  area  where  leakage  of  the  tank  or  connections 

could  cause  property  damage  to  the  area  adjacent  to  the 

appliance or to lower floors of the structure.

Chlorine  &  Aggressive  Water

:  The  water 

quality  can  significantly  influence  the  life  of 

this Product.  You should test for corrosive elements, acidity, total 

solids  and  other  relevant  contaminants,  including  chlorine  and 

treat your water appropriately to insure satisfactory performance 

and prevent premature failure. 

Note:

  Inspect for shipping damage and notify freight carrier or 

store  where  purchased  immediately  if  damage  is  present.    To 

avoid risk of personal injury and property damage, if the product 

appears to be malfunctioning or shows signs of corrosion, call a 

qualified professional immediately.  Current copies of the Product 

manual can be viewed at www.waterworkerdiy.com.  Use proper 

safety equipment when installing.

As in all plumbing products and water storage 

vessels,  bacteria  can  grow  in  this  Product, 

especially during times of non-use.  Consult your local plumbing 

professional regarding any steps you may wish to take to safely 

disinfect your home’s plumbing system. 

DANGER!  EXPLOSION  HAZARD,  WHEN  THE 

WELL  TANK  HAS  BEEN  IN  SERVICE  AND  A 

CHANGE TO A HIGHER PRE-CHARGE PRESSURE IS NECESSARY 

DUE  TO  A  REQUIRED  CHANGE  IN  THE  PRESSURE  SWITCH 

SETTING,  FAILURE  TO  FOLLOW  INSTRUCTION  MANUAL  CAN 

CAUSE  A  RUPTURE  OR  EXPLOSION,  POSSIBLY  CAUSING 

SERIOUS OR FATAL INJURY, AND/OR PROPERTY DAMAGE.

DO NOT ADJUST THE PRE-CHARGE PRESSURE IF THERE HAS 

BEEN A REDUCTION OF THE PUMP CYCLE TIME OR THE PRE-

CHARGE  PRESSURE  COMPARED  TO  ITS  INITIAL  SETTING.  

THIS  IS  BECAUSE  REDUCTION  IN  PUMP  CYCLE  TIME  CAN 

RESULT FROM LOSS OF TANK AIR PRESSURE WHICH IN TURN 

CAN MEAN THERE MAY BE INTERNAL CORROSION AND ANY 

RE-PRESSURIZATION  OR  ADDITIONAL  PRESSURE  COULD 

RESULT  IN  RUPTURE  OR  EXPLOSION,  AND/OR  PROPERTY 

DAMAGE. 

MAXIMUM WORKING PRESSURES.  

Every well 

tank  is  air  tested  to  125  psig,  the  maximum 

working pressure for the well tank line.  Should pressures exceed 

125 psig, proper selection and sizing of an ASME constructed well 

tank should be made.

RELIEF  VALVE  REQUIRED

.    A  relief  valve 

should  be  installed  which  is  set  to  open  at  

excessive  pressures  (75  psig  or  more).    This  will  protect  the  well 

tank  and  other  system  components  should  the  pressure  switch 

malfunction and fail to shut the pump off.  The relief valve should 

be installed at the connection of the well tank to the system piping 

and  have  a  discharge  equal  to  the  pump’s  capacity  at  75  psig. 

At  least  once  every  3  years  or  if  discharge  is  present,  a  licensed 

contractor  should  inspect  the  temperature  and  pressure  relief 

valve  and  replace  if  corrosion  is  evident  or  the  valve  does  not 

function. FAILURE TO INSPECT THIS VALVE AS DIRECTED COULD 

RESULT  IN  UNSAFE  TEMPERATURE  OR  PRESSURE  BUILD-UP 

WHICH CAN RESULT IN PRODUCT FAILURE, SERIOUS INJURY OR 

DEATH  AND/OR  SEVERE  PROPERTY  DAMAGE  AND  VOID  THE 

PRODUCT WARRANTY.

For your safety, the information in this manual 

must  be  followed  to  minimize  the  rise  of 

electric  shock,  property  damage  or  personal  injury.    Properly 

ground to conform with all governing codes and ordinances 

Do not use this tank for chemicals, solvents, petroleum products, 

acids,  or  any  fluids  other  than  potable  water.  This  can  cause 

premature failure due to corrosion.

Make sure that the pressure switch in your well system is set low 

enough  to  shut  off  the  pump.  If  all  of  the  faucets  and  valves  are 

closed  in  your  plumbing  system  and  the  pressure  switch  setting 

is too high, the pump can run continuously without moving water 

through the system. This could damage or burn out the pump.

CALIFORNIA  PROPOSITION  65  WARNING!

  

This product contains a chemical known by the 

State  of  California  to  cause  cancer  and  to  cause  birth  defects  or 

other reproductive harm. (California Installer/Contractor - California 

law requires that this notice be given to consumer/end user of this 

product.)  For  more  information:    www.waterworkerdiy.com/

prop65.htm

16

Summary of Contents for HT6HB

Page 1: ...MES WITH A 5 YEAR WARRANTY SEE WATER WORKER LIMITED WARRANTY FOR DETAILS READ CAREFULLY THE PRODUCT INSTALLATION OPERATING AND MAINTENANCE MANUAL FAILURE TO FOLLOW THE INSTRUCTIONS AND WARNINGS IN THE...

Page 2: ...osen the pipe once tightened If you do it is more likely to leak d Move the existing tank out of the way Discard e Move the new tank into position with the inlet assembly attached f If the two tanks a...

Page 3: ...alfunctioning or shows signs of corrosion call a qualified professional immediately Current copies of the Product manual can be viewed at www waterworkerdiy com Use proper safety equipment when instal...

Page 4: ...a WATER WORKER authorized distributor or retailer more than 30 days after expiration of the applicable warranty time period described in this Warranty this Warranty also does not cover repair or repla...

Page 5: ...t me pour puits Ce produit est fourni avec une garantie de 5 ans Voir la garantie limit e de WATER WORKER pour les d tails VEUILLEZ LIRE ATTENTIVEMENT LE MANUEL D INSTALLATION DE FONCTIONNEMENT ET D E...

Page 6: ...l extr mit du nouveau r servoir Serrez manuellement Puis bien serrer avec la cl tuyau et la cl ajustable de 30 48 cm 12 po Fig 7 8 Assurez vous que le tuyau la conduite d alimentation soit en positio...

Page 7: ...faillance pr matur e Remarque inspectez l appareil pour des dommages encourus lors de l exp dition Si vous constatez des dommages avisez imm diatement le transporteur ou le magasin o l achat a t effe...

Page 8: ...KER un distributeur ou un d taillant autoris WATER WORKER plus de 30 jours apr s l expiration de la p riode de garantie d crite dans la pr sente garantie La pr sente garantie ne couvre pas les co ts d...

Page 9: ...5 a os Consultar la Garant a Limitada de WATER WORKER para mas detalles LEA DETENIDAMENTE EL MANUAL DE INSTALACI N FUNCIONAMIENTO Y MANTENIMIENTO DEL PRODUCTO SI NO SIGUE LAS INSTRUCCIONES Y LAS ADVER...

Page 10: ...sici n vertical apuntando hacia arriba Ajuste lentamente para asegurarse de no ajustar de m s Fig 8 No afloje la tuber a una vez ajustada Si lo hace es m s probable que haya filtraciones d Quite el ta...

Page 11: ...materiales si el producto parece funcionar mal o muestra signos de corrosi n llame a un profesional calificado de inmediato Las copias actualizadas del Manual del producto se pueden encontrar en www w...

Page 12: ...un minorista o un distribuidor autorizado de WATER WORKER despu s de los 30 d as del per odo de tiempo de vigencia de la garant a descrita aqu Esta garant a tampoco cubre los costos de reparaci n ni...