STARTING UP THE SYSTEM

7

 

Check all connections to make sure the system has no leaks. Once you’ve verified all  

 

stages of regeneration are working appropriately, and have verified there are no    

 

leaks, fill the brine tank with sodium chloride or potassium chloride softening pellets.

Step 3. 

To ensure sanitary conditions in the mineral and brine tanks, place 1.5 ounces of   

 

common household bleach into the brine tank. Press and hold the REGEN button for 3  

 

seconds to move the control valve into regeneration sequence. Allow the FILL cycle to  

 

complete (5-8 min). Then press the REGEN button to allow the motor to move to the  

 

“SOFTENING” position and then push REGEN again, moving system to “DRAW”    

 

position. This cycle normally takes about 60 minutes; however, 15 minutes should be  

 

sufficient to pull the chlorine from the brine tank. After 15 minutes, press and hold   

 

the REGEN button to move the control valve to the “BACKWASH” position. Let the   

 

valve complete this cycle, and also the “RINSE” cycle, which will come next. Once the  

 

valve has completed the “RINSE” cycle, it will automatically return to “SOFTENING”.  

 

In step 5, you will set the valve to “Regen Today” so that it will regen the night after  

 

install at the specified time. If there is any residual chlorine, it will be removed during  

 

that regeneration.

Step 4. 

Make sure that the bypass valve is completely set in the “Normal Operation”  

 

 

position. Let the water in the taps of the building run for several minutes to purge the  

 

unconditioned water out of the pipes. After several minutes, take a water sample and  

 

test for hardness from the running tap. If a hardness test reads “soft” water, the    

 

installation is correct.

Step 5.

 Press and release the REGEN button. You should see “Regen Today” appear on the  

 

LCD screen. This will instruct the control valve to regenerate tonight at the specified  

 

time (usually 2:00 am).

Step 6.

 Drain hot water heater and let it refill with conditioned water. We suggest draining  

 

the hot water by turning on the hot water taps in the house. We recommend doing  

 

this just prior to bedtime.

Summary of Contents for Reionator Pro Ultra RXU13

Page 1: ...OWNERS MANUAL Whole House Water Conditioner With Triton Electronic Control Valve Activate your warranty by registering your product at watertech com or call 469 521 1180 ...

Page 2: ...to use in brine tank Customer knows where to purchase regenerant salt or potassium chloride Customer knows how often to check regenerant salt potassium level Customer knows how much salt or potassium chloride to put in brine tank Customer knows how to contact dealer in case of service needs Customer is aware that they must register their product online or by phone to activate their Reionator Pro l...

Page 3: ...nd that there is power at the receptacle If the unit does not respond with power present contact your WaterTech Dealer The manual bypass valve which is located at the rear of the unit is designed to isolate the unit from the plumbing for servicing or to shut off the water supply to the unit in the event of a leak at the conditioner Consult the operating diagram on page 11 of this manual for instru...

Page 4: ...ndry or other reasons DO contact your WaterTech Dealer if you have any questions about the operation of your system or water quality issues DO enjoy all the benefits of your Reionator Pro Ultra conditioned water DO NOT hang or stack items on your equipment This may cause an equipment imbalance or put a strain on plumbing and electrical connections DO NOT disconnect or remove any part of the plumbi...

Page 5: ...lve Overflow elbow PRODUCT DESCRIPTION Resin Tank 13 x 54 Brine Tank Assembled 18 x 33 Brine Well Assembly 4 0 x 29 Brine Overflow Elbow Triton Control Valve TX PART NUMBER 09 03 1354BLK XEMid 09 04 1833BKNG SIL 09 04 245 07 05 004 13 V1TXUMC MODEL RXU13 ...

Page 6: ...s Conditioned water in Check local codes for minimum run between Reionator Pro Ulta unit and water heater Hot Cold Hot water heater Triton Bypass Valve IMPORTANT Brass or Plastic yoke assembly not shown is required to connect piping to the bypass valve and is available in either NPT or solvent ...

Page 7: ...ne directly into drain sewer line or trap Always allow an air gap of at least 25mm 1 inch or 2 pipe diameters between the drain line and waste water to prevent the possibility of sewage being back siphoned Air gap Locking clip Drain line elbow Locking clip ...

Page 8: ...ystem puts water in brine tank to make brine If everything is working and you have verified that water in brine tank is rising press and release the REGEN button You will hear the motor engage and move the piston into the SOFTENING position Check all connections to make sure the system has no leaks To advance to the next stage of regeneration press and release the REGEN button You will hear the mo...

Page 9: ...ion Let the valve complete this cycle and also the RINSE cycle which will come next Once the valve has completed the RINSE cycle it will automatically return to SOFTENING In step 5 you will set the valve to Regen Today so that it will regen the night after install at the specified time If there is any residual chlorine it will be removed during that regeneration Step 4 Make sure that the bypass va...

Page 10: ...ce time is set press CLOCK SETTING HARDNESS Enter the Installer Screens by pressing and holding simultaneously for 3 5 seconds Once the display changes if the system is programmed to calculate grains of hardness the first display in the installer screens will be Water Hardness Use or to increase or decrease the hardness level based on the customers raw water total hardness Once the hardness level ...

Page 11: ...untered malfunction SETTING REGENERATION TIME Enter the Installer Screens by pressing and holding simultaneously for 3 5 seconds Once the display changes press until you reach the Regeneration Time display When on the Regeneration Time display use or to adjust the hour The hours will cycle through AM and PM Press to move the cursor to adjust the minutes Use or to adjust the minutes Advance to the ...

Page 12: ...ponding Bypass Valve Instructions on the following page Figure 1 Normal Operation Position The inlet and outlet handles point in the direction of flow indicated by the engraved arrows on the control valve Water flows through the control valve during normal operation and this position also allows the control valve to isolate the media bed during the regeneration cycle Figure 2 Bypass Position The i...

Page 13: ...ter enters Supply water exits Supply water enters Supply water exits Supply water enters No water exits Supplywater is shut off from the house and valve FIGURE 1 NORMAL OPERATION FIGURE 2 BYPASS OPERATION FIGURE 3 DIAGNOSTIC MODE FIGURE 4 SHUT OFF MODE POSITION ...

Page 14: ...nt salt 2 Softening capacity values based on NaCl as the regenerant salt Model Max Recommended Flow Rate Service Flow Rate Gallons per minute RXU13 11 0 9 Max Flow to Drain During Regeneration Gallons per minute PSID Total Bed Depth FT3 7 5 2 350 Efficiency rated softeners shall have a rated salt efficiency of not less than 3350 grains of total hardness exchange per pound of salt and shall not del...

Page 15: ...t quality water treatment media certified to NSF Standards If upon factory inspection the resin is found to be defective Water Tech Industries will furnish replacement resin The resin warranty does not cover resins subjected to water containing greater than 3 0 ppm of free chlorine or chloramines or containing greater than 1 0 ppm total Iron and or Manganese Resin which has been fouled by iron man...

Page 16: ...thermore this warranty expressly excludes any system which has been out of service for more than 90 days continuously Fulfillment of the warranty coverage by WTI is contingent on proper execution of the procedures set forth in the WTI Warranty RGA policy No person or representative is authorized to assume for Water Tech Industries any liability on its behalf or in its name except to refer the purc...

Reviews: