background image

WATER SOURCE LLC 

WWW.WATERSOURCEUSA.COM 

Warns of hazards that 

CAN

 cause serious personal injury, death or major property 

damage if ignored. 

SEE BELOW FOR LIST OF WARNINGS

 

1. This pump is designed for home sump applications.

2. This pump will provide years of trouble-free service when properly installed, maintained, and used.

However, inadequate electrical power to the pump, dirt, or blockage by ice or debris may cause the pump to

fail, eventually bringing about additional water damage. To minimize the potential for water damage due to

pump failure, please carefully read the manual and follow the instructions regarding common pump
problems and remedies or call 1-800-346-7611.

3. For safety, the pump motor has an automatic resetting thermal protector that automatically will turn off the

pump if it becomes too hot. Overuse of this feature will damage the pump and will void the warranty.

4. Once the thermal protector detects that the pump has cooled to a safe temperature, it will allow the pump

to operate normally. If the pump is plugged in, it may restart unexpectedly.

Additional Safety Precautions 

1. Know the pump applications, limitations, and potential hazards.
2. Make certain the electrical power source is adequate for the requirements of the pump.
3. ALWAYS disconnect the power to the pump before servicing.
4. Release all pressure (drain all water) within system before servicing any component.

5. Secure discharge line before starting pump. An unsecured discharge line will whip, possibly causing personal

injury and/or property damage.

6. Secure the pump on a solid base to keep the pump vertical and above mud and sand during operation to

maximize pumping efficiency and prevent clogging and premature pump failure.

7. Check that all pipe connections are tight to minimize leaks.
8. Connect the pump DIRECTLY to a grounded, GFCI outlet on a 15-Amp or larger dedicated circuit breaker.

9. Extension cords should not be used.

10. Periodically inspect the pump and system components to be sure the pump inlet is free of mud, sand, and

debris. DISCONNECT THE PUMP FROM THE POWER SUPPLY BEFORE INSPECTING.

11. Wear safety glasses at all times when working on the pump.
12. Follow all electrical and safety codes, particularly the National Electrical Code (NEC) and in the workplace,

the Occupational Safety and Health Act (OSHA).

13. This unit is designed only for use on 115 volts (single phase), 60 Hz, and is equipped with an approved

3-conductor cord and 3-prong grounded plug. DO NOT REMOVE THE GROUND PIN UNDER ANY
CIRCUMSTANCES. The 3-prong plug must be directly inserted into a properly installed and grounded

3-prong, grounding-type receptacle. Do not use this pump with a 2-prong wall outlet. Replace the 2-prong
outlet with a properly grounded 3-prong receptacle (a GFCI outlet) installed in accordance with the National

Electrical Code and local codes and ordinances. All wiring should be performed by a qualified electrician.

14. Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do

not use damaged or worn cords.

Summary of Contents for WSSPC3

Page 1: ...This pump is controlled by the attached float switch The proper application is for use as a sump pump in a basement By using in a sump pit the rising water will activate the float switch turning the pump on Questions Problems Missing parts Please call our pump experts before returning to the store 1 800 346 7611 8 a m 4 30 p m EST Monday Friday WSSPC5V 1 2 HP ...

Page 2: ... tape Tools Required Screwdriver Hacksaw to cut pipe Knife to assist in pipe cutting File to smooth pipe ends Adjustable wrench to tighten fittings SAFETY INSTRUCTIONS This is a SAFETY ALERT SYMBOL When you see this symbol on the pump or in the manual look for one of the following signal words and be alert to the potential for personal injury or property damage Warns of hazards that WILL cause ser...

Page 3: ...efore starting pump An unsecured discharge line will whip possibly causing personal injury and or property damage 6 Secure the pump on a solid base to keep the pump vertical and above mud and sand during operation to maximize pumping efficiency and prevent clogging and premature pump failure 7 Check that all pipe connections are tight to minimize leaks 8 Connect the pump DIRECTLY to a grounded GFC...

Page 4: ...g 4 Based on the float switch operation this pump will not remove all the water in the sump pit 5 Set your new pump in the bottom of the sump pit off to one side The pump MUST be placed on a solid foundation such as a brick stone paver or other flat heavy surface Do not place the pump directly on the ground in sandy or rocky surfaces Clay earth sand or gravel that enters the pump could damage the ...

Page 5: ...comes air locked it will not pump water To prevent this situation the drilled hole in the pipe will allow any trapped air to escape and your pump will work as it should 7 Apply PVC primer and solvent to PVC adapter and PVC pipe then insert pipe into adapter and allow solvent to set 8 Place your pump in the sump pit on top of a brick stone paver or other solid surface so that pump is not directly o...

Page 6: ...nd pumps out sump pit but does not stop Float switch is stuck in up on position Be sure float switch operates freely in pit Defective float switch Replace with new float switch Pump runs but delivers only a small amount of water Pump is air locked Start and stop several times by plugging and unplugging cord Check for clogged vent hole in discharge pipe Vertical pumping distance head is too high Re...

Page 7: ...sing Motor 1 N A 8 Impeller 1 WSSPC IMP 2 Pump base 1 WSSPC PBG 9 Washer 1 3 Gasket 1 10 Washer 1 4 Vertical Float Switch 1 WSSPCV RS 11 Nut 1 5 Cable 1 12 Handle 1 N A 6 Cable fitting 2 13 Screw 8 N A 7 Bracket 1 16 Cable Gland 2 N A 14 Screw 2 17 Packing 2 N A 15 Screw 2 18 ADAPTER 1 BUSH 125 150 19 Tether Float Switch 1 WSSPC TRS ...

Page 8: ...sclaims any implied warranties of merchantability and fitness for a particular purpose 3 In no event shall Water Source LLC be liable for consequential incidental or special damages resulting from or related in any manner to any distributor components or accessories 4 Water Source LLC disclaims all liability for improper installation or improper use of this product Some states do not allow the exc...