OPERATING DISPLAYS AND MAINTENANCE

1 .  

GENERAL OPERATION: 

When the system is operating, one of four displays may be shown and will alternate with the installing 

dealer’s name and phone number for future service . Pressing 

NEXT

 will alternate between the displays . 

 1 . 

 CURRENT TIME OF DAY

 and 

GPM

 2 . 

 FLOW  RATE

 which is the current treated water flow rate through the system in Gallons Per Minute

 

3.  CAPACITY REMAINING

 which is the gallons that will be treated before the system signals a regeneration cycle

 4 . 

 DAYS TO A REGEN

 is the number of days left before the system goes through a regeneration cycle, based on the days 

override value

 

5 . 

DEALER NAME AND PHONE NUMBER

 will only appear if set by the dealer . This scrolling display offers dealer    

     

    contact information for instances when service is needed .

     If the system has called for a regeneration that will occur at the preset time of regeneration, the words “REGEN TODAY” will 

appear on the display .

     If a water meter is installed, “GPM” flashes on the display when water is being treated, indicating gallons per minute going 

through the system .

2 .  

REGENERATION MODE: 

Typically a system is set to regenerate at a time of 

no water usage . If there is a demand for water when the system is regenerating, 

untreated water will be delivered . When the system begins to regenerate, the 

display will include information about the step of the regeneration process and the 

time remaining for that step to be completed . The system runs through the steps 

automatically and will reset itself to provide treated water when the regeneration 

has been completed .

3 .  

MANUAL REGENERATION: 

Sometimes there is a need to regenerate before 

the control valve calls for it . This may be needed if a period of heavy water use is 

anticipated or when the system has been operated without salt .

 

•  To initiate a manual regeneration 

at the next preset regeneration time,

 press 

and release 

REGEN

 . The words “REGEN TODAY” will flash on the display 

to indicate that the system will regenerate at the next regeneration time (set 

in Programming, steps 4 and 5) . 

If you pressed the 

REGEN

 button in error, 

pressing the button again will cancel the command.

 

•  To initiate a manual regeneration 

immediately,

 press and hold the 

REGEN

 

button for three seconds . The system will begin to regenerate immediately . 

This command cannot be cancelled.

      Once a manual regeneration is initiated, the unit will go into the FILL position . This position allows water to enter the brine 

tank until it reaches the proper level . Once this position is complete, you will notice a 240 Minute (4 hours) SOFTENING 

position . This 4-hour window allows the salt to dissolve and achieve proper brine strength . During these FILL and 

SOFTENING positions, you will have softened water available for use . Once the unit advances to the BACKWASH position 

and subsequent positions thereafter (see Start Up Instructions for regeneration sequence), the water softener will deliver water, 

but it will be untreated . 

     

 IMPORTANT:

 With the Dry Salt Storage Feature, the brine tank will refill 4 hours before the actual regeneration occurs . 

You may experience a small amount of noise for a short period of time at 10:00 p .m . (with typical setting) on the night that 

regeneration is to occur . This noise is only the brine tank filling and at no time during this process will you be without treated 

water . 

The user can scroll between the displays as desired .

1

FLOW RATE

GPM

8.0

CAPACITY REMAINING

2

5

TIME OF DAY

MON

PM

GPM

2:40

8

GAL

GPM

1600

8

GPM

3

8

3

DAYS TO A REGEN

4

555 5555555

DEALER NA

BACKWASH

8:22

REGENERATION MODE

MANUAL REGENERATION 

REGEN TODAY

MON

GPM

2:40

8

PM

REGEN TODAY 

and 

TIME OF DAY 

will flash alternately if a regeneration 

is expected tonight.

Summary of Contents for Impression RC Series

Page 1: ...ion RC Series Metered Water Softeners For Models IM 844 IMP 844 IM 948 IMP 948 IM 1044 IMP 1044 IM 1054 IMP 1054 IM 1248 IMP 1248 IM 1354 IMP 1354 IMC 835 IMPC 835 IMC 1035 IMPC 1035 IMRC 1054 IMPRC 1...

Page 2: ...efore installing This manual should be kept for future reference If you have any questions regarding your water softener contact your local dealer or Water Right at the following Water Right Inc 1900...

Page 3: ...Remaining and Days to a Regeneration are optional displays but are not normally used Each of these can be viewed by pressing NEXT to scroll through them When stepping through any programming if no but...

Page 4: ...r flows through the control valve for normal operation of a water softener or filter During the regeneration cycle this position provides regeneration water to the unit while also providing untreated...

Page 5: ...nd the water conditioner should be as short as possible see step 8 2 Since salt must be added periodically to the brine tank it should be in an easily accessible location 3 It is NOT recommended to in...

Page 6: ...this could cause interior damage to the flow control Install a 1 2 I D flexible plastic tube to the Drain Line Assembly or discard the tubing nut and use the 3 4 NPT fitting for rigid pipe recommende...

Page 7: ...tion however an overflow line connection will direct the overflow to the drain instead of spilling on the floor where it could cause considerable damage This fitting is an elbow on the side of the bri...

Page 8: ...increments NOTE If a resin media is used in the softener increase the grains per gallon if soluble iron is present 1 ppm 4 gpg This display will show GALLONS AVAILABLE BETWEEN REGENERATIONS if FILTER...

Page 9: ...the inlet handle of the bypass valve very slightly allowing water to fill the tank slowly in order to expel air CAUTION If water flows too rapidly media will be lost to the drain 3 When the water is f...

Page 10: ...ed or when the system has been operated without salt To initiate a manual regeneration at the next preset regeneration time press and release REGEN The words REGEN TODAY will flash on the display to i...

Page 11: ...l valve was not able to function properly 6 BRINE TANK MAINTENANCE AND SALT Refill the brine tank as necessary making sure at least 1 3 of the brine tank is full at all times Without proper salt level...

Page 12: ...Restricted stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin connector D Verify meter cable wires are installed secure...

Page 13: ...G Check refill setting in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Control valve body type a...

Page 14: ...ston position or disconnect power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap PC board into drive bracket and then Press NE...

Page 15: ...seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect Then reprogram valve to proper setting B MAV NHBP motor wire not conne...

Page 16: ...uzzer will activate and the screen will display the error A Check for low flow leak Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply...

Page 17: ...17 This page left intentionally blank...

Page 18: ...lack Impression Plus cover 1 CV3540P W A Gray Impression Plus cover 1 2 CV3107 1 Motor 1 3 CV3002A Drive bracket spring clip Includes 5 6 1 4 CV3579WI PC board Impression 1 CV3813WP PC board Impressio...

Page 19: ...nerant piston 1 6 CV3180 O ring 337 1 7 CV3105 O ring 215 1 8 CV3556 Screw 1 4 20x1 1 2 18 8SS 1 9 CCI 00318337 Nut 1 4 20 HEX 18 8SS 1 10 CV3016 QC2 clamp assembly includes screw nut 1 11 CV3452 O ri...

Page 20: ...PARTS 2 4 1 3 BRINE ELBOW ASSEMBLY Item No Part No Description Qty 1 CV3195 01 Refill port plug assembly 1 2 CH4615 Elbow locking clip 1 3 CV4144 3 8 Elbow Parker fitting 1 4 CV3163 O ring 019 1 Altho...

Page 21: ...embly BLUE CV3010 1G G injector assembly YELLOW CV3010 1H H injector assembly GREEN CV3010 1I I injector assembly ORANGE CV3010 1J J injector assembly LIGHT BLUE CV3010 1K K injector assembly LIGHT GR...

Page 22: ...n 1 Strt No Sil 1 REPLACEMENT PARTS Water flow Proper DLFC orientation directs water flow towards the washer face with rounded edge DRAIN LINE ASSEMBLY 3 4 Item No Part No Description Qty 1 CH4615 Elb...

Page 23: ...1030 36S 4 x 36 slotted brine well 18 x 40 24 x 40 BT s 1 5 CH1018 2 piece overflow set 1 6 CH4500 48 474 air check assembly 1 2 x 48 1 7 CH4620 474 float assembly 7 1 8 CH4600 50 474 safety brine val...

Page 24: ...AND BRINE TANK Item No Part No Description Qty 1 CJ2TCWS HEH Top Assembly Light Gray Dark Gray 1 2 CJ2B35E Bottom Assembly Light Gray with 474 Brine Assembly 1 Not shown CH4850 34 625 Brine Well with...

Page 25: ...25 This page left intentionally blank...

Page 26: ...CV3105 O ring 215 2 4 CV3188 Fitting 2 3 4 BRASS SWEAT Item No Part No Description Qty CV3007 03 3 4 brass sweat assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2...

Page 27: ...2 3 CV3105 O ring 215 2 4 CV3629 Fitting 2 3 4 BRASS SHARK BITE Item No Part No Description Qty CV3007 12 3 4 brass Shark Bite assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105...

Page 28: ...ure Range PSI 25 100 25 100 25 100 25 100 25 100 25 100 Water Temp F 33 100 33 100 33 100 33 100 33 100 33 100 Electrical Requirements volts hertz 110 50 60 110 50 60 110 50 60 110 50 60 110 50 60 110...

Page 29: ...replace the part or component at its expense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes an...

Page 30: ...stored in memory no matter how long the power outage 1 Accessed by pressing SET CLOCK 2 Adjust hours with and buttons AM PM toggles at 12 3 Press NEXT 4 Adjust minutes with and buttons 5 Press NEXT 6...

Page 31: ...31 This page left intentionally blank...

Page 32: ...1900 Prospect Court Appleton WI 54914 Phone 920 739 9401 Fax 920 739 9406 2018 Water Right Inc All rights reserved MAN IM IMP SOFT RevA0818...

Reviews: