background image

9

3/8" DRAIN CLAMP ASSEMBLY

Drain Clamp

Front Plate

Drain Pipe

1/4" Nut

1/4" Screw

Drain Clamp

Back Plate

Black Drain Tubing

Figure 4 

C.  Drain Clamp Installation 
  Choose the drain outlet location per Sec. III, C.5. 
  The following are instructions for discharging 

into the sink drain pipe. (Refer to Fig. 1.) 
1.  Position the Drain Clamp on the sink drain 

pipe above the drain trap. Allow room for 

drilling. Tighten securely. 

2.  Use a battery powered or properly grounded 

drill. Using the Clamp port as a drill guide,  

drill a 

7

/

32

" hole through the wall of the drain 

pipe. Do NOT penetrate the opposite side of 

the pipe. 

3.  Locate the 

3

/

8

" Black Drain Tubing connected 

to the Dispensing Faucet. Route to the tubing 

to the Drain Clamp and trim to length. 

  NOTE: When cutting the polytubing make  

clean, square cuts, failing to do so could 

result in poor connections and possible 

leaks. 

  CAUTION: The lowest point of the line 

should be the point of connection to the Drain 

Clamp. There should be no sag in the line as 

this may cause excessive noise as the reject 

water is flowing to drain.
•Refer to Fig. 4. Insert the tubing into the 

Drain Clamp. Make sure the tubing is 

pressed all the way in to create a pressure 

tight connection.

NOTE: If you want to pull the tubing out for 

some reason, push the ring around the tubing 

in and pull the tubing out.

D.  R.O. Manifold Assembly Installation 
  Locate the site per Sec. III, C.3. Various 

installation sites will require different types 

of mounting fasteners; be sure the fastener 

selected will provide a firm, solid mounting. 

A support panel may be necessary on thin 

cabinet walls or to span between wall studs on 

particleboard or drywall. 

  Do not drill through exterior cabinet walls or 

leave sharp wood screw points exposed in 

readily accessible cabinet interiors. 

  The close proximity of a dishwasher or a trash 

compactor may require special fabrication of a 

mounting plate. 
1.  The mounting bracket will accept either #10 

or #12 (5mm) mounting screws spaced on 

6" (15 cm) centers. Allow at least 4" (10 cm) 

of clearance beneath the filter housings to 

accommodate filter changes. Mark the two 

locations (the bracket can be used as a 

template). Install the screws and tighten them 

until the heads are about 

5

8

" from the wall.

RED

BLACK

YELLOW

IN

DRAIN

OUT

DRAIN 

RESTRICT

OR

2.  Locate the ¼" Red Feed Water Tubing. 

Remove the red plug from the fitting labeled 

“In” on the manifold and insert the tubing. 

Reference the special supplement sheet in 

the carton for proper connection of all tubing 

and removal of plugs. Run the tubing along 

its course to the Feed Water Saddle Valve, 

trim to length. (Refer to Fig. 1.)

  Refer to Fig. 3. To the end of the red polytube 

install the Compression Nut, the  Plastic 

Ferrule, and the Insert. Connect to the Feed 

Water Saddle Valve.

3.  Locate the ¼" Black Drain Tubing connected 

to the Dispensing Faucet. Remove the black 

plug from the fitting labeled “Drain” on the 

manifold. The end of the Black Drain Tubing 

that should be inserted into the “Drain” port 

will have a drain restrictor in it. Allow the 

tubing to relax, then press drain restrictor 

firmly again to insure proper seating.

Summary of Contents for Clear Flo

Page 1: ...REVERSE OSMOSIS DRINKING WATER SYSTEM INSTALLATION OPERATION SERVICE MANUAL Drink With Confidence...

Page 2: ...ATION STEPS 8 A Faucet Installation 8 B Feed Water Saddle Valve Installation 8 C Drain Clamp Installation 9 D R O Manifold Assembly Installation 9 E Position the Drinking Water Holding Tank and Make t...

Page 3: ...to tastes and odors The activated carbon in the Prefilter has been designed to reduce any chlorine that may be present in the feed water This pretreatment is also necessary for membrane protection RE...

Page 4: ...Less than 0 1 ppm also mg l Manganese Less than 0 05 ppm also mg l Hydrogen Sulfide None Chlorine See note Bacteria Must be potable NOTE Chlorine will damage a T F C Membrane The Activated Carbon Pref...

Page 5: ...FEED WATER SADDLE VALVE Cold Water Line Only LOCATE DRAIN CLAMP ABOVE P TRAP 4 MIN REVERSE OSMOSIS MEMBRANE HOUSING ACTIVATED CARBON PREFILTER HOUSING SEDIMENT PREFILTER HOUSING 1 4 Yellow POLYTUBE TE...

Page 6: ...cluded REVERSE OSMOSIS MEMBRANE HOUSING ACTIVATED CARBON PREFILTER HOUSING SEDIMENT PREFILTER HOUSING BASEMENT FLOOR PLEASE NOTE IF AIR GAP IN FAUCET IS NOT USED IN BASEMENT INSTALLATIONS A PROPER AIR...

Page 7: ...inking water is normally obtained Convenience of use filling of water pitchers and glasses and an open area beneath the faucet under the sink for attaching product and drain tubing are considerations...

Page 8: ...Water Saddle Valve counter clockwise outward until the lance does not protrude from the gasket It may have to be pushed in Assemble the Feed Water Saddle Valve on the tubing for 3 8 OD tubing use the...

Page 9: ...of mounting fasteners be sure the fastener selected will provide a firm solid mounting A support panel may be necessary on thin cabinet walls or to span between wall studs on particleboard or drywall...

Page 10: ...t in place Make sure the tubing is pressed all the way in to create a pressure tight connection F Start Up At time of start up and each time the filters are changed the system should be sanitized also...

Page 11: ...lve will start water production and the system will refill the Holding Tank When the Holding Tank is full and no water is being used the ASO Valve will automatically shut off the feed water to conserv...

Page 12: ...bing that runs from the Holding Tank to the Tee see Fig 1 Put 50 drops of bleach this is tsp or 3 ml into the tubing and reconnect it to the Tee NOTE Now is the convenient time to change the In Line A...

Page 13: ...13 NOTES...

Page 14: ...14 NOTES...

Page 15: ...15 NOTES...

Page 16: ...e check The ASO Valve is malfunctioning Replace ASO Valve components Low pressure at the Dispensing Faucet In Line Activated Carbon Post Filter is plugged Replace Post Filter Air precharge in the Hold...

Page 17: ...r in the Holding Tank Clean flush and sanitize the system Replace the filters The Product Water and Drain Water lines are reversed Correct plumbing Dissolved gasses in the Feed Water Pretreat Feed Wat...

Page 18: ...18 MADE IN USA EXPLODED VIEW PARTS LIST 19 1 2 3 4 5 6 7 8 9 10 11 12 13 14 18 16 17 OUT IN 20 15 21 Membrane Carbon Prefilter Sediment Prefilter...

Page 19: ...1 10 and 15 and 16 9 CS1276 Check Valve 10 CS1277 Check Valve Retainer 11 CS7111 Sediment Prefilter 12 CS7125 Activated Carbon Prefilter 13 CS3069 Housing O Ring 14 CS3010BLK Housing 15 CJG PI0808S 1...

Page 20: ...to return the defective part s What Does This Warranty Not Cover This warranty does not cover the disposable sediment and carbon filters whose service life depends on feed water conditions In addition...