Types of alarms and audible warnings

Low sensor battery

If a sensor’s battery is low, 2.75 V or less, the sensor will periodically 
send a low battery signal to the control panel. The corresponding 

LED will flash orange and is accompanied by a beeping sound every 

15 seconds until the situation is resolved. The sensor batteries should 
be replaced soon.

Critical sensor battery

If a sensor’s battery is very low, 2.70 V and less, the sensor will send 
a critical battery signal to the control panel. The corresponding LED 

is orange and a rapid beeping sound is heard for 15 minutes. The 

LED will remain orange until the situation is corrected. The valve will 
close. The batteries in the corresponding sensor must be replaced as 
soon as possible.

Water detection

If a sensor detects water, the corresponding LED is red and an 
audible alarm is emitted. The valve closes immediately and remain 
closed as long as the sensor is detecting water. When the situation is 
resolved, the valve can be reopened by using the remote control or 
by pressing 

Reset

Sensor communication loss - IOK

The control panel receives a presence signal from each installed 
sensor. If a sensor signal is not received for 12 consecutive hours, 

the corresponding LED will flash green and an audible warning is 

emitted. If a signal has not been received for over 24 hours, the LED 

flashes red and an audible alarm is emitted, causing the valve to 

close.

Power failure

The control panel is equipped with a 9 V battery backup. This 
ensures that the control panel continues to function and that the 
valve remains open in the event of a power failure. If the battery 
backup reaches a critical level, the valve will close and remain closed 
until the battery is replaced and the system reset, or until power is 
restored.

Low temperature Alarm

The control panel and sensors are equipped with temperature 
sensors. If the ambient temperature drops near freezing (5°C), the 
valve will close and remain closed until the system is reset. The

 batt/

temp.

 LED will alternate between red and orange.  

Other types of alarms

Emergency power mode 

If the system goes into emergency power 

mode (9V battery or rechargeable battery) due 

to a power failure, the colour remains the same. 

Only the display time changes in some cases 

to save batteries energy. The Wi-Fi connection 

remains active for 3 minutes while a final status 

update is sent to the web platform.  If the 

system goes into emergency power mode (9V 

battery or rechargeable battery) due to a power 

failure, the colour remains the same. Only the 

display time changes in some cases to save 

batteries energy. The Wi-Fi connection remains 

active for 3 minutes while a final status update 

is sent to the web platform. 

It is recommended to change 

the batteries of all sensors 

every 12 months or in case of 

extended use due to water 

detection.

Alarms with valve closure and audible warnings 

without valve closure

LEDs are green when the sensor status is normal. The 

Cancel

 button 

can be used to silence an active audible alarm. The audible alarm 

will resume one hour later unless the problematic situation has 

been resolved.
Audible warnings that do not close the valve are in «auto-reset» 

mode. When the warning disappears, it is automatically cancelled 

on the panel (e.g. the audible motion warning disappears when the 

sensor has not been in motion for 1 minute). The auto-reset delay 
depends on the type of alarm.

Alarms that cause the valve to close do not reset automatically. 
They must be cancelled by pressing the 

Reset

 button or the 

Cancel

 

button on the remote control. Other audible alarms do not have this 
reset delay and return immediately when received.

Summary of Contents for E 2.0

Page 1: ...ts or damage caused by the use of parts other than original Water Protec parts are not covered by this warranty Please note that the warranty does not include damage caused by improper installation or...

Page 2: ...at must be placed in strategic locations on the floor for example near the water heater sinks etc The sensors send an alarm signal if the stainless steel electrodes simultaneously detect water They al...

Page 3: ...2 sensor synchronization The basic Water Protec kit includes 5 sensors but it is possible to add as many as needed The sensors can be identified on the control panel 20 zones can be pro grammed Press...

Page 4: ...then the control panel into the power outlet Reopen the water inlet Make sure there is no air in the plumbing by opening a tap at the highest point of the residence If the bathtub has been left open t...

Page 5: ...ct the Wi Fi LED is red To activate this mode 1 Press the Cancel button for 3 seconds a If the manoeuvre was successful LEDs 1 to 4 light green in sequence 2 Press the Program button located on the le...

Page 6: ...until the battery is replaced and the system reset or until power is restored Low temperature Alarm The control panel and sensors are equipped with temperature sensors If the ambient temperature drop...

Page 7: ...alve closed Fixed Closed Open Close Not connected valve Fixed Open Close Valve malfunction Flash WiFi Not used WiFi Connected to Wifi Fixed WiFi Lost connection Fixed Procedure following a water detec...

Page 8: ...ipting XSS protection Protects against the majority of XSS attacks allowing a user to inject client side scripts into other users browsers SSL HTTPS protects against malicious network users to detect...

Reviews: