Thermostat with Automatic

Heat/Cool Changeover Option

PART NO. 37-7194C

Replaces 37-7194B

1045

Heat Pump Installation and Operating Instructions 

APPLICATIONS 

SPECIFICATIONS 

Electrical Rating:
 

Battery Power  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   mV to 30 VAC, NEC Class II, 50/60 Hz or DC

 

Input-Hardwire   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   20 to 30 VAC

Terminal Load   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   1 .5A per terminal, 2 .5A maximum all terminals combined
Setpoint Range  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   45 to 99°F (7 to 37°C)
Differential (Single Stage)  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   Heat 0 .6°F; Cool 1 .2°F
Differential (Multi-Stage)   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   Heat 0 .6°F; Cool 1 .2°F
Differential (Heat Pump)   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   Heat 1 .2°F; Cool 1 .5°F
Operating Ambient .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   32°F to +105°F (0 to +41°C)
Operating Humidity   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   90% non-condensing max .
Shipping Temperature Range   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   -40 to +150°F (-40 to +65°C)
Dimensions Thermostat .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   4-9/16"H x 5-13/16"W x 1-3/16"D

CAUTION

!

To prevent electrical shock and/or equipment damage, 
disconnect electric power to system at main fuse or 
circuit breaker box until installation is complete.

ATTENTION: MERCURY NOTICE
This  product  does  not  contain  mercury .  However,  this 
product may replace a product that contains mercury .

Mercury  and  products  containing  mercury  must  not  be 
discarded  in  household  trash .  Do  not  touch  any  spilled 
mercury . Wearing non-absorbent gloves, clean up any spilled 
mercury and place in a sealed container . For proper disposal 
of a product containing mercury or a sealed container of 
spilled  mercury,  place  it  in  a  suitable  shipping  container . 
Refer to http://thermostat-recycle .org for location to send 
the product containing mercury . 

Programming Choices

Non-Programmable

5/1/1 Day

7 Day

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS 
CAREFULLY BEFORE INSTALLING OR OPERATING THIS 
CONTROL COULD CAUSE PERSONAL INJURY AND/OR 
PROPERTY DAMAGE.

THERMOSTAT APPLICATION GUIDE

Description

Heat Pump (No Aux . or Emergency Heat)

Yes

Heat Pump (with Aux . or Emergency Heat)

Yes

Systems with up to 3 Stages Heat, 2 Stages Cool

Yes

Heat Only Systems

Yes

Cool Only Systems

Yes

Wired Remote Temperature Sensor (Indoor/Outdoor)

Yes

Dual Fuel Feature (Heat Pump Mode)

Yes

Save this instructions for future use!

Index

Page

Installation

2

Wiring Connections

3

Wiring Diagram

3

Thermostat Quick Reference

4

Installer Configuration Menu

5

Operating Your Thermostat

8

Programming

8

Troubleshooting

12

Summary of Contents for TP32W03

Page 1: ...at contains mercury Mercury and products containing mercury must not be discarded in household trash Do not touch any spilled mercury Wearing non absorbent gloves clean up any spilled mercury and plac...

Page 2: ...thermostat one at a time Do not let wires fall back into the wall Installing New Thermostat 1 Pull the thermostat body off the thermostat base Forcing or prying on the thermostat will cause damage to...

Page 3: ...C W E Jumper G C W2 Jumper No Output 1st Stage Heat Cool Com pressor Blower Circula tor Fan Energiz ed on call for Heat or Cool 24 VAC Hot Cool DC supply voltage to re mote Temp erature Sensor Remote...

Page 4: ...e 12 Call For Service indicates a fault in the heating cooling system It does not indicate a fault in the thermostat Programming and Configuration Items Figure 3 Programming Configuration Items 13 Sys...

Page 5: ...I Selects Backlight Intensity 13 13 11 0 4 LO to 4 HI Selects Adjustable Ambient Temperature Display range 4 LO to 4 HI 14 14 12 F C Selects F C Display temperature units in Fahrenheit or Celsius 15 1...

Page 6: ...and 98 F by pressing the or key The temperature limit icon will be displayed to the left of your setpoint temperature when using this feature The temperature limit icon will flash if an attempt is mad...

Page 7: ...IGURATION MENU 2 C or more above the actual temperature using the second stage will energize immediately With FA OFF second stage will not energize until the setpoint tempera ture is 1 F or more above...

Page 8: ...ure setting for a default four hour over ride period The override period can be shortened by pressing or lengthened by pressing Program Override period can range from 15 minutes to 7 days Example If y...

Page 9: ...n the fan on for 10 minutes and off for 20 minutes to improve indoor air quality If the display shows FAN On Prog to indicate the program period has the fan programmed to run FAN Prog will override th...

Page 10: ...th the times and temperatures you want Keep the following guidelines in mind when planning your program In Heating lower temperatures will save energy In Cooling higher temperatures will save energy I...

Page 11: ...or is fixed In normal operation of the thermostat the current tempera ture displayed will be the weighted average of the local sensor and the remote sensor using the formula local sensor weight x loca...

Page 12: ...at to COOL and lower the setpoint below the room temperature There may be up to a five minute delay before the thermostat clicks in Cooling Heat Cool or Fan Runs Constantly 1 Possible short in wiring...

Reviews: