Water Factory Systems CoolerMATE CMTRO-75 Owner'S Manual Download Page 2

SAFETY INFORMATION

EXPLANATION OF SIGNAL WORD CONSEQUENCES

WARNING

CAUTION

IMPORTANT NOTES

Read, understand, and follow all safety information contained in these instructions prior to installation and use of the CMTRO-75™ 
Reverse Osmosis (RO) Drinking Water System. Retain these instructions for future reference.

Intended use:

The CMTRO-75 Reverse Osmosis (RO) Drinking Water System is intended for use in fi ltering potable water in the home or offi ce and has not 
been evaluated for other uses.  The system is typically installed in a cooler, under a sink or in a basement, and must be installed as speci-
fi ed in the installation instructions.

C

CAUTION

WARNING

Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury 
and/or property damage.

Indicates a potentially hazardous situation, which, if not avoided, may result in minor or moderate injury 
and/or property damage.

Indicates a potentially hazardous situation, which, if not avoided, may result in property damage.

To reduce the risk associated with choking:

 • 

Do not

 allow children under 3 years of age to have access to small parts during the installation of this product.

To reduce the risk associated with ingestion of contaminants:

 • 

Do not

 use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.  Systems certi-

fi ed for cyst reduction may be used on disinfected water that may contain fi lterable cysts. EPA Establishment Number 070595-CT-001

To reduce the risk associated with hazardous voltage due to an installer drilling through existing electric wiring or water pipes in the area of 
installation:

 • 

Do not

 install near electric wiring or piping which may be in path of a drilling tool when selecting the position to mount the fi lter bracket.

To reduce the risk of physical injury:

  • Shut off inlet water supply and depressurize system as shown in manual prior to cartridge removal.

 

• All hydropneumatic pressurized tanks must have an appropriate pressure relief valve installed.

To reduce the risk with back strain:

  • Follow safe lifting procedures.

To reduce the risk associated with eye, skin and respiratory and digestive tract burns from Calcium Hypochlorite during installation:

  • Calcium Hypochlorite (CAS 7778-54-3) granules are used for tank sanitization in this product.
  • During installation, do not get in eyes or on skin or clothing. Do not ingest. Wear eye and face protection. Keep out of reach of children.
  • To request an MSDS relating to this product, call 203-238-8965 or visit the web at http://solutions.3m.com/wps/portal/3m/en_us/MSDS (click 

MSDS search).  For emergencies, call 800-364-3577 or 651-737-6501 (24 hours).

To reduce the risk associated with ingestion of water contaminated with sanitizer:

  • After installation, sanitizer 

MUST

 be fl ushed from the system before fi rst use as directed within the installation instructions.

To reduce the risk of injury associated with household bleach:

  •  Read and follow manufacturers directions and cautions.  Keep out of reach of children.
 • 

DO NOT

 intermix with other chemicals.

To reduce the risk associated with property damage due to water leakage:

 • 

Read and follow

 Use Instructions before installation and use of this system.

  •  Installation and Use 

MUST

 comply with all state and local plumbing codes.

 • 

Protect from freezing

, remove fi lter cartridge when temperatures are expected to drop below 40°F (4.4°C).

 • 

Do not install on hot water supply lines

.  The maximum operating water temperature of this fi lter system is 100°F (37.8°C).

 • 

Do not install

 if water pressure excee

ds 100 psi (689 kPa). 

 If your water pressure exceeds 80 psi (552 kPa), you must install a pressure limiting 

valve.  Contact a plumbing professional if you are uncertain how to check your water pressure.

 • 

Do not install

 where water hammer conditions may occur.  If water hammer conditions exist you must install a water hammer arrester.  Contact 

a plumbing professional if you are uncertain how to check for this condition.

 • 

Do not

 use a torch or other high temperature sources near fi lter system, cartridges, plastic fi ttings or plastic plumbing. 

  •  Where a backfl ow prevention device is installed on a water system, a device for controlling pressure due to themal expansion must be installed.
  •  All hydropneumatic pressurized tanks must have an appropriate pressure relief valve installed.
  •  On plastic fi ttings, never use pipe sealant or pipe dope.  Use PTFE thread tape 

only

. Pipe dope properties may deteriorate plastic.

  •  Take care when using pliers or pipe wrenches to tighten plastic fi ttings, as damage may occur if overtightening occurs.
 • 

Do not

 install in direct sunlight or outdoors.

 • 

Do not

 install near water pipes which will be in path of a drilling tool when selecting the position to mount the bracket.

 • Mount 

fi lter in such a position as to prevent it from being struck by other items used in the area of installation.

  •  Ensure that the location and fasteners will support the weight of the system when installed and full of water.
 • 

Do not

 install unit if collet is missing.  Contact CUNO Tech Services (203-238-8847) if collets are missing from any fi ttings.

  •  Ensure all tubing and fi ttings are secure and free of leaks.
  •  The disposable fi lter cartridge 

MUST

 be replaced every 18 months, at the rated capacity or if a noticeable reduction in fl ow rate occurs.

  •  Failure to follow instructions will void warranty.
  •  Allow a minimum of 2” (5.1 cm) clear space under fi lter to facilitate cartridge change.
  •  Install with the inlet and outlet ports as labeled.  Make sure not to reverse connections.

CAUTION

Summary of Contents for CoolerMATE CMTRO-75

Page 1: ...olerMATE Reverse Osmosis Systems Model CMTRO 75 System tested and certified by NSF International against NSF ANSI Standard 42 and Standard 58 for the claims specified on the Performance Data Sheet Installer Please leave this manual with owner operator End User Please retain for operation and future maintenance instructions ...

Page 2: ...37 6501 24 hours To reduce the risk associated with ingestion of water contaminated with sanitizer After installation sanitizer MUST be flushed from the system before first use as directed within the installation instructions To reduce the risk of injury associated with household bleach Read and follow manufacturers directions and cautions Keep out of reach of children DO NOT intermix with other c...

Page 3: ...ing to cooler Filter Icon Feedwater Inlet 1 4 Green Polyethylene Tubing with Flow Control Assembly To StorageTank 3 8 Yellow Polyethylene Tubing Back View of Bracket Drain Line Green Tubing Flow Control Assembly Back View of RO Cartridge 1 2 Flow Control RO Drain Line Construction 1 Insert the thin flow control tubing with attached bushing and stop into the 1 4 green tubing 2 Insert the green tubi...

Page 4: ...There are two slots with keyholes to provide a variety of options for bolting or hanging the CMTRO 75 system on the cooler In some cases existing screws can be used Further there are keyholes for those who desire to install studs bolts or screws at the required spacing to allow easy removal of the entire system Make tubing connections With the CMTRO 75 system fastened to the cooler the tubing conn...

Page 5: ...he end of the threaded tank stem Install the 3 8 x 1 4 tank valve onto the threaded tank stem Do not overtighten 2 Disconnect the 3 8 yellow tubing from the back of the filtration assembly and connect one end of it into the tube fitting located on the tank valve 3 Connect the other end of the 3 8 yellow tubing to the 3 8 x 1 4 union connector included in the tank sanitization kit 4 Connect the fre...

Page 6: ...ion and Maintenance Instructions Replacing the Filter Cartridges The life of the prefilter cartridge generally depends on the local water conditions i e sediment rust and or chlorine levels while the life of the postfilter cartridge s is generally determined by the length of service It is recommended that the cartridges be replaced as noted below When to Replace the Sediment Carbon Prefilter Cartr...

Page 7: ...completely depressurize 2 Make sure that there is some slack in the green tubing connected to the fitting at the bottom of the RO membrane cartridge Twist the cartridge 1 4 turn to the left so that the tubing connection is accessible See illustration on the right 3 Remove the green tubing by depressing the small white collet and pulling the tubing away from the fitting Note It is advisable to chec...

Page 8: ...800 733 1199 Worldwide 1 203 237 5541 Fax 1 203 238 8701 www waterfactorysystems com www cuno com 2009 3M Company All rights reserved CUNO CMTRO 75 and Water Factory Systems are trademarks of 3M Company used under license NSF is a trademark of NSF International a 3M company ...

Reviews: