5
Start
-
up Procedure
Turn bypass valve on unit(s) (located above water piping connections) to
“
bypass
”
posi-
tion and open water supply feeding irrigation system.
(See Illustration 6 for control keypad).
Flush the TurfMaster system:
(On duplex systems, this process should be done individually
on each control unit.
)
Press and hold the
“
Extra Cycle
”
button for 5 seconds.
1.
The control panel will begin to flash
“
BW
-
-
-
-
“
indicating it is entering
“
Backwash
”
mode. After about 30 seconds,
”
-
-
-
-
”
will be replaced with a counting down clock. Slowly
open the bypass valve on the back of the unit. Water will begin to run to the drain, flushing
the system. Allow this water to run for about 5 minutes, and then press the
“
extra cycle
”
button, briefly this time.
2.
The control panel will begin to flash
“
BD
”
-
-
-
-
“
indicating it is entering
“
Brine Draw
”
mode. After about 30 seconds,
“
-
-
-
-
“
will be replaced with a counting down clock and wa-
ter will run to the drain, again flushing the system. Allow this water to run for about 5
minutes, and then press the
“
Extra Cycle
”
button briefly again.
3.
The control panel will flash
“
-
-
-
-
“
indicating it is returning to service mode. After about 1
minute, the control panel will indicate between the current time of day setting, and the fac-
tory pre
-
set regeneration override period of 3 days. The unit is now back in service and
ready for flow.
Illustration 6
−
While in service, the Data Display alternates between time
of day, volume remaining or days to regeneration.
−
The Flow Indicator flashes when outlet flow is detected.
−
The Faucet Icon flashes if a regeneration cycle has been
queued.