8
1899 Cottage Street
Ashland, Ohio 44805
Telephone: 1-844-394-2604
Page 1: ...WA33CSW Wide Angle Switch Owner s Manual WACS Series Cast Iron Sump Pumps General Safety 2 Specifications 3 Installation 4 5 Troubleshooting 6 Warranty 7 TABLE OF CONTENTS WA75CSV Vertical Switch ...
Page 2: ...jury Indicates a hazard which if not avoided will result in death or serious injury Indicates a hazard which if not avoided could result in death or serious injury Indicates a hazard which if not avoided could result in minor or moderate injury NOTICE indicates practices not related to personal injury Keep safety labels in good condition Replace missing or damaged safety labels General Safety Risk...
Page 3: ...4000 27 Cast Iron Thermoplastic 8 1 2 WA50CSV 1 2 115 1 8 0 4400 27 Cast Iron Thermoplastic 8 1 2 WA75CSW 3 4 115 1 8 0 6000 34 Cast Iron Thermoplsatic 8 3 4 WA75CSV 3 4 115 1 8 0 6000 34 Cast Iron Thermoplsatic 8 3 4 2 MNPT x 1 1 2 FNPT Adapter included WA33CSW WA33CSV WA50CSW WA50CSV WA75CSW WA75CSV 327 8 12 92 ECD25W ECD33W ECD50W 221 8 8 73 SWITCH OFF 401 8 15 82 SWITCH ON ECD75W REF50W 357 8 ...
Page 4: ...us 7 The following may cause injury and or severe damage to pump and will void the warranty a Using an extension cord b Cutting off the ground pin or using an adapter fitting c Working on pump or switch while plugged in d Removing motor housing unscrewing impeller or otherwise removing impeller seal e Running the pump continuously f Pumping chemicals or corrosive liquids g Pumping gasoline or othe...
Page 5: ... Pump must be placed on a hard sur face in a sump that has been cleared of all debris Never place the pump on clay earth or gravel surfaces and it is suggested the pump be placed on two bricks approximately 2 apart STEP 3 Connect the discharge pipe fittings and check valve to the discharge port of the pump It is recommended that the discharge pipe diameter be equal to or larger than the discharge ...
Page 6: ...ace float switch Pump is air locked Start and stop several times by plugging in and unplugging cord Check for clogged vent hole in pump case Vertical pumping distance is too high Reduce distance or change the discharge fitting of the pump Inlet holes in pump base are clogged Remove pump and clean the strainer and openings Impeller or volute openings are fully or partially clogged Remove pump and c...
Page 7: ... corrective action as promptly as reasonably possible No requests for service will be accepted if received more than 30 days after the warranty expires Warranty is not transferable and does not apply to products used in commercial rental applications General Terms and Conditions Limitations of Remedies You must pay all labor and shipping charges necessary to replace product covered by this warrant...
Page 8: ...8 1899 Cottage Street Ashland Ohio 44805 Telephone 1 844 394 2604 ...