IMPORTANT INSTRUCTIONS BEFORE INSTALLATION

Failure to follow these instructions may cause serious bodily injury and/or property damage.

Save this manual for future reference. 

This is the safety alert symbol.

 When you see this symbol 

on your pump or in this manual, look for one of the following 
signal words and be alert to the potential for personal injury:

DANGER 

warns about hazards that 

will

 cause serious personal 

injury, death or major property damage if ignored.

WARNING 

warns about hazards that 

can

 cause serious personal 

injury, death or major property damage if ignored.

CAUTION 

warns about hazards that 

will

 or 

can

 cause minor 

personal injury or property damage if ignored.
The label

 NOTICE 

indicates special instructions which are 

important but not related to hazards.

Carefully read and follow all safety instructions in this manual 

and on pump.

Keep safety labels in good condition. 
Replace missing or damaged safety labels.

WARNING. Severe personal injury or death could result from 

improperly sizing the pump, or from using it for any purpose 

other than as an in-ground pool pump.

 Hazards may include, 

but are not limited to, electrical shock, fire, flooding, suction 
entrapment, or structural failure of the pump or other system 
component.

WARNING. Pressure testing hazards.

•  Do not allow people to work around components under test.
•  Post appropriate warnings and barriers around pressurized 

equipment.

•  Test for the minimum time allowed by local codes.
•  If the equipment is located in a separate room, close and lock 

the door and post warning signs.

ELECTRICAL

This pump must be wired through a Ground Fault Circuit 
Interrupter (GFCI) to protect the circuit. To reduce the risk of 
electrical shock, connect the green terminal on the pump to the 
grounding terminal of your electrical service or supply panel. Use 
a conductor at least as large as the wires conducting power to the 
pump. Refer to local or national codes for details.
Installations must comply with the National Electrical Code or the 
Canadian Electrical Code, as applicable, and all applicable local 
codes and ordinances.

GENERAL

Pool main drain installation must comply with current local and 
national building, electrical, plumbing and pool/spa codes, as 
applicable.
Prime the pump (fill the pump and piping system with water) 
before starting it for the first time. If you do not get satisfactory 
circulation within 5 minutes, stop the pump and reprime it. Do 
not allow the pump to run for an extended period of time with no 
water moving. In these conditions, the pump may overheat and 
start a fire or possibly explode.

WARNING. Explosion hazard, with risk of severe 

injury or death.

 Always stop the pump and relieve all 

pressure in the system before adjusting or releasing 

any fastenings. Make sure there is no air in the system (use the 
air bleed valve on the pool filter to  release any trapped air in the 
system). NEVER adjust, loosen or tighten any lid clamps or bolts 
while the system is pressurized.

WARNING. Risk of electrical shock – can burn or 

kill. 

Always disconnect power to the pump at the 

circuit breaker before servicing or working on the 
pump. Make sure that no one can connect the power 

without your knowledge and consent.

WARNING. Fire and burn hazard.

 Do not allow leaves 

and debris to collect around the pump. Do not allow 
children around the pump and filter areas. Allow the 
pump motor to cool for 20 minutes before working  
on it.

DANGER. Hazardous Suction. Can trap hair or body, causing 

severe injury or death.

•  Do not block circulation pump suction. MAKE SURE that all main 

drains are correctly installed, with anti-entrapment covers, 
listed to ASME A112.19.8, screw-fastened in place, and that 
any vacuum outlets are protected by self-closing, self-latching 
vacuum covers listed to IAPMO SPS-4 2000.

•  Keep small children under close adult supervision around the 

pool at all times.

•  NEVER allow anyone (adult or child) to sit on a pool main drain.
•  Very small children sometimes think that a main drain is really 

a place to “go potty”. Don’t let them do this!

B

od

y

F

or

eA

rm

Upp

er

Arm

Leg Jo

int

Leg

 J

oi

nt

Leg 

Joi

nt

Leg

 Jo

in

t

Summary of Contents for RSP10

Page 1: ...t observer toutes les consignes de sécurité et tous les avertissements avant d installer ou d utiliser ce produit sinon on risque de subir des blessures corporelles graves mortelles ou causer des dommages matériels importants Pour toute question concernant l installation le fonctionnement l utilisation l entretien ou pour obtenir des exemplaires supplémentaires de ces instructions appeler le Servi...

Page 2: ...allations must comply with the National Electrical Code or the Canadian Electrical Code as applicable and all applicable local codes and ordinances General Pool main drain installation must comply with current local and national building electrical plumbing and pool spa codes as applicable Prime the pump fill the pump and piping system with water before starting it for the first time If you do not...

Page 3: ...o will cause damage to mechanical seal leakage and flooding WARNING Explosion hazard Never run pump against closed discharge valve To do so can cause high temperatures pump damage personal injury and property damage WARNING Hazardous voltage Can shock burn or cause death Read instructions before installing To avoid dangerous or fatal shock hazard turn off power and ground motor before connecting m...

Page 4: ...or STEP 1 General Tools and Materials Needed Electrical cable with ground wire Ground fault circuit breaker Rigid 1 1 2 PVC pipe and fittings or reinforced flex hose and hose clamps Pump Filter Backwash valve not required on cartridge filter Shut off valves Hacksaw with 24 tooth blade for cutting plastic pipe Knife or round file for smoothing inside of plastic pipe connections Screwdriver pipe wre...

Page 5: ...50 385 600 RSP7 15 3 4 230 5 9 400 630 990 1545 2405 RSP10 10 1 115 14 4 128 200 310 485 RSP10 20 1 230 7 2 300 475 660 1030 1650 RSP15 10 1 1 2 115 20 8 142 222 345 RSP15 25 1 1 2 230 10 4 220 350 545 860 1325 15 SWIMMING POOL WIRE FUSE SELECTION CHART MAINTENANCE AND SERVICE Priming the Pump To prime the pump remove the lid from the strainer and fill the pump and basket with water Turn cover cou...

Page 6: ...ks and that it slopes gradually from pump to pool with no high or low spots Make sure pump shaft turns clockwise when viewed from motor end opposite shaft Check for plugged impeller Make sure the check valve is not sitting in sand or mud and that it is not stuck shut Pump delivers water for a period of time then stops pumping Check for plugged impeller Check for a suction leak Check for blocked su...

Page 7: ...rt Qty No No Description Req d 1 25051A008 3 4 HP Motor RSP7 1 1 25051A009 1 HP Motor RSP10 1 1 25051A010 1 1 2 HP Motor RSP15 1 2 05059A318 Slinger 1 3 25053A000 Shaft Seal 1 4 19101A010 Cap Screw 3 8 x 1 6 5 25054B001 Impeller RSP7 1 5 25054B002 Impeller RSP10 1 5 25054B003 Impeller RSP15 1 6 25059D000 Seal Plate 1 7 25060D000 Diffuser Housing 1 B G Below Ground If shaft seal 3 is replaced also ...

Page 8: ...er installation operation maintenance or storage nor to other than normal application use or service including but not limited to operational failures caused by corrosion rust or other foreign materials in the system or operation at pressures in excess of recommended maximums Requests for service under this warranty shall be made by returning the defective product to the Retail outlet or to WATER ...

Page 9: ... Pour de plus amples détails consulter les codes du gouvernement national et de la municipalité L installation doit être conforme au National Electric Code ou au code canadien de l électricité selon le cas et à tous les décrets et codes en vigueur de la municipalité GÉNÉRALITÉS L installation du drain principal de la piscine doit être conforme aux codes en vigueur de la construction de l électrici...

Page 10: ...aisser les enfants utiliser ce produit 3 AVERTISSEMENT Risques d électrocution Cet appareil ne peut être connecté qu à une prise protégée par un interrupteur de fuite à la terre Si vous ne pouvez confirmer que la prise est protégée par une dispositif de fuite à la terre contactez un électricien 4 Avant de procéder à l installation vérifiez le code électrique national et les normes locales en vigue...

Page 11: ...ec tuyaux flexibles Connectez la canalisation d aspiration venant de l écumeur de la piscine et ou de l orifice de vidage à l orifice d entrée de la pompe Si la pompe est installée à côté d une piscine hors terre une vanne d arrêt est nécessaire Pump Suction Line Optional Shut Off Valves can be installed in the filter inlet and outlet lines to allow isolation of the filter for service Inlet Line f...

Page 12: ...cipal Une boîte de fusibles ou un disjoncteur doit être installé sur ce circuit voir tableau de fusibles Si la pompe est branchée sur une prise existante vous risquez d avoir une tension insuffisante sur le moteur de faire griller un fusible de déclencher l interrupteur de surcharge du moteur ou de brûler le moteur Tout le câblage doit respecter les normes locales en vigueur Remarque En cas de dou...

Page 13: ...dommager la pompe et les tuyaux AVERTISSEMENT Ne pas utiliser de liquide antigel courant Les liquides antigel pour automobile sont fabriqués avec de l éthylène glycol un produit très toxique qui ne s évapore pas Le méthanol est également très toxique mais il peut s évaporer s il est suffisamment exposé à l atmosphère Plusieurs liquides lave glace sont fabriqués avec de l alcool méthylique une autr...

Page 14: ...ration fuit Vérifiez si la canalisation d aspiration est bouchée Vérifiez si l impulseur frotte Le moteur surchauffe et s arrête surcharge Assurez vous que le moteur est correctement câblé en fonction de la tension reçue Vérifier le câblage le calibre des fils est peut être trop petit Consultez le tableau de sélection des câbles en page 3 Assurez vous que l impulseur ne frotte pas contre l enceint...

Page 15: ...HP RSP7 1 1 25051A009 Moteur 1 HP RSP10 1 1 25051A010 Moteur 1 1 2 HP RSP15 1 2 05059A318 Chasse goutte 1 3 25053A000 Joint de scellée d arbre 1 4 19101A010 Vis d assemblage 3 8 po x 1 po 6 5 25054B001 Impulseur RSP7 1 5 25054B002 Impulseur RSP10 1 5 25054B003 Impulseur RSP15 1 6 25059D000 Plaque de scellée mécanique 1 7 25060D000 Enceinte du diffuseur 1 SNS Sous le niveau du sol Si le joint de sc...

Page 16: ... limiter aux produits ayant subi des pannes de fonctionnement causées par la corrosion la rouille ou par des corps étrangers qui se seraient introduits dans le système ou aux produits ayant fonctionné à des pressions dépassant les pressions maximales recommandées Toute demande de service au titre des présentes garanties devront être faites en retournant le produit défectueux au détaillant ou à WAT...

Page 17: ...éctrico Nacional o el Código Eléctrico Canadienses según corresponda y con todos los códigos y ordenanzas locales aplicables INFORMACIÓN GENERAL La instalación del sumidero principal de la piscina debe cumplir con los códigos actuales locales y nacionales de construcción eléctricos de plomería y de piscinas y jacuzzis según el caso Cebe la bomba llene la bomba y el sistema de tuberías con agua ant...

Page 18: ...to martillo en el agua y dañar la bomba 14 GUARDE ESTAS INSTRUCCIONES Hay que cebar la bomba Asegúrese de que esté llena de agua antes de ponerla en funcionamiento En caso de no hacerlo se producirán daños en el sello mecánico habrá fugas y se producirá una inundación ADVERTENCIA Riesgo de explosión Nunca ponga la bomba en funcionamiento con la válvula de descarga cerrada No hacerlo podrá producir...

Page 19: ...iales generales necesarios Cable eléctrico con conductor de conexión a tierra Interruptor accionado por corriente de pérdida a tierra Tubería y accesorios de 1 1 2 de cloruro de polivinilo rígido o manguera flexible reforzada y abrazaderas para manguera Bomba Filtro Válvula de contraflujo no se necesita en el filtro del cartucho Válvulas de cierre Sierra para cortar metal con cuchilla de 24 diente...

Page 20: ...ncipal Se deberá usar una caja de fusibles o un disyuntor de circuito en esta línea véase la tabla de fusibles Hacer la conexión en los enchufes existentes podría causar que el motor reciba un voltaje bajo lo cual causará que se fundan los fusibles se desconecte el disyuntor por sobrecarga o se queme el motor Todo cableado deberá seguir los códigos locales Nota Si tuviera alguna duda llame a un el...

Page 21: ...l etileno el cual es altamente venenoso y no se evapora El alcohol metílico es también altamente venenoso pero se evaporará si se expone lo suficiente a la atmósfera Muchas soluciones para el parabrisas están compuestas de hidrato de metilo el cual es muy venenoso Todos estos anticongelantes que se han mencionado anteriormente tienen un fuerte efecto de deterioro en algunos materiales plásticos qu...

Page 22: ...haya fugas en la succión Compruebe que la línea de succión no esté obturada Compruebe que el impulsor no esté rozando El motor se sobrecalienta y se apaga sobrecarga Asegúrese de que el motor esté cableado correctamente para el voltaje correcto Comprobar el cable el tamaño del cable puede ser demasiado pequeño Véase la tabla de selección de la página 3 Asegúrese de que el impulsor no esté tocando ...

Page 23: ...lo de fuerza RSP7 1 1 25051A009 Motor de 1 caballo de fuerza RSP10 1 1 25051A010 Motor de 1 1 2 caballos de fuerza RSP15 1 2 05059A318 Anillo lubricante del vástago 3 25053A000 Sello de vástago 4 19101A010 Tornillo de cabeza hexagonal 3 8 x 1 5 25054B001 Impulsor RSP7 5 25054B002 Impulsor RSP10 5 25054B003 Impulsor RSP15 6 25059D000 Placa de sellado 7 25060D000 Carcasa del difusor 1 1 6 1 1 1 1 1 ...

Page 24: ...alación operación mantenimiento o almacenamiento inadecuados ni tampoco debido a aplicaciones usos o servicios que no sean normales incluyendo pero sin limitarse a fallas operacionales provocadas por corrosión herrumbre u otros materiales extraños en el sistema o un funcionamiento a presiones que excedan los máximos recomendados Las solicitudes de servicio bajo esta garantía se deberán realizar me...