background image

1

2

4

7

6

3

5

8

13

Watco Innovator

®

 Cable Bath Wastes

Installation Instructions Continued

© 2011 Watco Manufacturing Company

 

Page 2

 

970INST  Rev. 4/11

Figure 7

Figure 8

Figure 9

Figure 12

Figure 11

WATCO MANUFACTURING COMPANY

1220 South Powell Road

Independence, MO  64057-2724

Phone: 816-796-3900 • 800-821-8576

Fax: 816-796-0875 • 800-399-2826

www.watcomfg.com

Figure 10

19

20

21

22

24

25

Step 1:

 Remove 

stopper seal.

Step 2:

 Slide Theft-

Resistant device into 

stopper slot.

Step 3:

 Replace 

stopper seal.

Step 4:

 Insert stopper shaft into strainer body, pushing it in until the hook 

on the Theft-Resistant device snaps into place under the strainer body.

If installing the Theft-Resistant Option:

Step 9: 

Select the faceplate adapter (

Item 5, 6, or 7

) that leaves 

the desired gap between the tub wall and the edge of the faceplate 

(

Item 2

).

 (

See included adapter selection instruction sheet.)

 

Place adapter onto the drive shaft (

Item 8

) (

Figure 7

). 

If you have 

selected  an adapter that is too short, the spacer tabs on the inside of 

the faceplate will rub on the OE nut (

Item 3

), and the adapter screw 

hole will not line up with the faceplate screw hole.

  

Once the desired faceplate adapter is determined, secure the 

faceplate adapter to the drive shaft using the screw provided (

Item 4

(

Figure 8

). 

Secure the faceplate (

Item 2

) to the faceplate adapter 

(

Figure 9

) using 

either

 the faceplate screw (

Item 1

(

Figure 10

). 

(Leave the plastic sleeve on threads to help 

align the screw.)

 

or

 the optional ADA  handle. 

 

Tighten the faceplate screw until it is flush with the faceplate and snug 

 

(or if using the handle, until it is snug). 

DO NOT OVERTIGHTEN.

Step 10:

 

Rotate the faceplate 

CLOCKWISE 

to the 

fully-closed position

.  Install the core 

guide (

Item 22

) into the strainer body using a screwdriver or 7/16” socket (

Figure 11

). 

(

See core guide instruction card included with kit.) The core guide should be screwed in 

until it is snug against the bottom of the drain elbow.

 Insert the stopper (

Item 24

) into the 

core guide (

Item 22

) (

Figure 12

). 

Step 11:

 Test the cable unit for proper operation.  In the fully-closed position, with the 

faceplate (

Item 2

) rotated clockwise, the stopper (

Item 25

) should rest and seal on the 

strainer body flange.  In the fully-open position, with the faceplate (

Item 2

) rotated 

counterclockwise past the click, the stopper should open to a height of ½” - ¾” above the strainer body flange.  The plastic 

cable core should move freely inside the core guide (

Item 22

) when the faceplate is turned. Adjustments to the open height 

can be made using the stopper adjustment screw (

Item 24

). 