Wiring Description
:
J1: Power Supply
12V
:
DC 12V Positive
GND
:
Ground
J2: Door Bell
Normally, J2 outputs open signal if
is not pressed.
If door bell is used,
is pressed and J2 will outputs close signal to drive door bell rings.
J3: 485 Interfaces
An IC232 or RS485HUB is needed to connect host PC.
Customer can set all configurations when connected to host PC. Moreover user
authorization and exporting card events can also be done via AccessWatch3000.
J4: TCP/IP Interfaces
Available to use a switch or directly connect to host PC via Ethernet port.
Customer can set all configurations when connected to host PC. Moreover user
authorization and exporting card events can also be done via AccessWatch3000.
J5: External Reader Interfaces
12V
:
External reader power supply (Positive)
D0
:
Wiegand input
D1
:
Wiegand output
LED: Indicator connector
GND
:
Ground.
BUZ: Buzzer connector
J6: Door Contact, Rex Button, Auxiliary Input
BUT
:
Rex Button connector
(
GND for the other side
)
.
SEN
:
Magnetic switch connector
(
GND for the other side
)
.
GND
:
Negative
(
Public side
)
.
IN1
:
Auxiliary input 1.
IN2
:
Auxiliary input 2.
J7: Built-in Reader Output
12V
:
Positive
D0
:
Wiegand output 0
D1
:
Wiegand output 1
LED: Indicator connector
GND
:
Negative
(
Public side
)
.
BUZ
:
Buzzer connector
J8: Electronic Lock
、
Relay Output
Based on customized lock model.
2.3 Lock Wiring Diagram
J4: Relay Output
(
Lock Control
)
As shown below.