background image

WGSMSC Quick Start Guide 

2

1. Using the WGSMSC as an SMS Communicator

1.1 Usage Overview

1.2 Installation Requirements

1.3 Product Diagram

9~36VDC In: 

Power input

Alarm Panel: 

Alarm panel 
connection

Land Line: 

Land line 
connection

OC Output: 

OUT1 

- 1st output, OC type 

COM

 - General terminal 

OUT2

 - 2nd output, OC type

USB Port: 

Connect to PC for configuration

Indicator Lights:
1.

SMS Signal

Blinking every 0.5s

 - Registering network 

Blinking every 1.0s

 - Normal signal

2.

Power Supply

Blinking every 1.0s

 - Battery charging 

On

 - Battery fully charged 

Off

 - No power from battery or adapter

3.

GPRS Data

Blinking every 1.0s

 - Transferring GPRS data

4.

Ethernet 

Blinking

 - Transferring GPRS data 

On 

- Connected to server

ANT:  

Included antenna connects here

Ethernet: 

Network cable connection

Before installation, ensure the following are accounted for: 

One installed and active alarm panel (Watchguard™ WGAP864 recommended)

One PC / laptop for communicator configuration via USB

One active SIM card for SMS communication

Mobile network connection

This section covers how to set up the WGSMSC for use as an SMS alarm communicator. In this configuration, the communicator 
can notify up to 5 users via SMS for events such as alarm activation and power loss. This turns your alarm into a self monitored 
alarm system that can be used inline with your monitoring service.

In this section, learn how to connect and configure your communicator via PC, set up which mobile numbers the communicator 
contacts, alarm events and messages sent in response and how to connect the communicator to the alarm panel.

Fig. 1.3.1: 

WGSMSC diagram & connections

Summary of Contents for WGSMSC

Page 1: ...ntact ID alarm panels The communicator is able to send contact ID alarm events via SMS over the mobile network to up to 5 mobile devices It can simultaneously communicate via IP 3G 4G Ethernet to a co...

Page 2: ...cluded antenna connects here Ethernet Network cable connection Before installation ensure the following are accounted for One installed and active alarm panel Watchguard WGAP864 recommended One PC lap...

Page 3: ...ommunicatorK5SV1 1 exe from the zip onto the PC 3 Launch the program It will open to the Basic Information tab by default 4 At the top right of the configuration software select a Com Port eg COM1 and...

Page 4: ...erts for 8 different alarm zones in the same partition with each area and sensor type covered 4 Save all changes with the Save Settings button 1 4 Configuration via PC continued 1 4 3 Mobile Alarm Set...

Page 5: ...communicator 6 Connect the communicator to a 9 36VDC power supply to turn it on Plug In 8 Zone Expander WGAP864EXP816 9 10 11 12 13 14 15 16 D 16V AC x D 1 2 3 4 5 6 7 P 5 4 3 2 1 PROG OUTPUTS ZONE Z...

Page 6: ...a Arm your alarm b Trigger a known zone c Wait to receive an SMS notification to your programmed phone s This may take up to 1 minute depending on telephone carrier and signal strength Ensure the mob...

Page 7: ...w Password please remember it carefully SMS Command Return SMS Message PASSWORD EE Example 1234EE Model WGSMSC Version V 1 00 2018 04 IMEI 867965029050313 GSM Signal Value 30 Action SMS Command Return...

Page 8: ...ol PASSWORD DOP SERIAL Example 1234DOT1 Action SMS Command Return SMS Message IP settings PASSWORD IP IP ADDRESS P PORT Example 1234IP183 12 162 70P4005 Server 182 12 162 70 Port 4005 Check IP setting...