Dual-Tech Motion Sensor (PIR&Microwave) 

with Pet Immunity 

-

Fig 1 Knockout holes 

Bracket Installation - Wall  mount bracket 

·

Fig 2 Detector Installation  - - - - - -

·····• 

The  detector  provides  an  analysis  of  environmental  conditions 

through  the  entire  movement speed  frequency spectrum, allowing 

focus  on  intruders  and  eliminating  environmental  factors  of false 

alarms.  The  spectrum  analysis  is  embedded  in  the  VLSI  based 

electronics  of  the  detector  assuring  high  reliability  and  trouble 

free operation. 

As  the 

ALH-PIRMW

  is  a  combined  technology  (PIR  &  microwave) 

alarm  signal  relay  activation  occurs  only  when  signals  from  both 

sensors  (PIR  &  MW)  are  present  at  the  same  time.  The  effective 

detection  range  is  the  range  of  which  the  patterns  (PIR  &  MW)  are 

intersected. The  GAIN  potentiometer adjustment changes  the  MW  signal 

intensity so  that the  effective pattern will be  scaled. 

This  Installation  Manual  shall  be  used  in  conjunction  with  the 

Installation Manual  of the ALARM  Control  Panel. 

TYPICAL INSTALLATION 

Select mounting location 

Choose  a  location  most  likely  to  intercept  an  intruder.  (Our 

recommendation  is  a corner installation). See  detection pattern  (Fig.3). 

The  quad•element  high  quality  sensor  detects  motion  crossing  the 

beam;  it  is  slightly less sensitive detecting motion  toward the  detector. 

Avoid The Following Locations:• Facing  direct sunlight.• Facing areas 

that  may  change temperature  rapidly.  • Areas  where  there  are  air  ducts 

or  substantial airflows. 

The 

ALH-PIRMW

  perform

s

  better  when  provided  with  a constant 

and  stable environment. 

This  detector  shall  be  installed  and  used  within  an  environment  that 

provides  the  pollution  degree  max  2 and  overvoltages  category  II,  NON 

HAZARDOUS  LOCATIONS,  indoor  only.  The  detector  is  designed  to  be 

installed by  service persons only. 

MOUNTING THE  DETECTOR 

1.

Remove  the  front  cover  by  unscrewing  the  holding screw  (Fig.  2-11) 

and  gently raise the  front  cover. (Fig. 2 ·S) 

2.

Remove  the  PC  board  by  unscrewing the  holding screw located  on 

the board.(Fig. 2 -

 

9) 

3.

Break  out  the  desired  holes  for  proper  installation  (Fig.  1 -

 

2)  for 

fiat mount or  Fig.  1 ·3  for corner mount) Use  4 screws type 3x30mm. 

4.

The  circular and  rectangular indentations  at  the  bottom  base  (Fig. 

1· 1,  Fig.  1-4)  are  the  knockout holes for wire entry. 

5.

Mount the detector base  to  the wall  or  corner. 

7.

Reinstall the  PC  board  by  fully tightening the  holding screw. 

8.

Connect wire  to  terminal  block.(Fig. 4) 

9.

Replace  the  cover  by  inserting  it  back  in  the  appropriate  closing 

pins.and screw in  the  holding screw.

If back  tamper  is  assembled  (Fig.1-6)  there  is  no  bracket  option  and  the 

detector must be  installed  in  nat mounting only. 

DETECTOR INSTALLATION 

Terminal Block Connections (See Fig. 4) 

Terminal  1 -

 

Marked"." (GND)  Connect to  the  negative Voltage  output 

or ground of the  control panel. 

Terminal 2 •Marked"+" ( +12V) Connect to  a positive Voltage output of 

9.6·16VDC source.  Use only a listed power limited source. 

Terminals  3 & 4 • Marked  TAMPER  Connect  these  terminals  to  a 24· 

hour  normally  closed  protective  zone  in  the  control  unit.  If  the  front 

cover  of the  detector is  opened,  an  immediate  alarm  signal  will  be  sent 

to  the control  unit. 

Terminal  6 & 7 Marked  RELAY· These  terminals  are  the  NC  (Normally 

Closed)  output  and  COMMON  output  of  ALARM  relay.

SETTING· UP THE DETECTOR (Dipswitch Fig.5-2) 

LED  ENABLE/ DISABLE 

Switch 1 ofdipswitch marked  "LED" - LED's  Enable/Disable 

Position Up  "ON" - LED's ENABLE The 3 LED's will  be  activating Red  for 

ALARM, Green  for PIR detection, Yellow for  MW  detection. 

Position  Down  "OFF" - LED's  DISABLE The  LED's  are  disabled. 

NOTE:  The  state  of the  switch  "LED"  - does  not  affect  the  operation  of 

the  relays.  When  an  intrusion  is  detected,  the  alarm  relays  will  switch 
into alarm  condition  for 2 sec. 

PIR SENSITIVITY ADJUSTMENT 

Switch  2 of dipswitch  marked  "PIR"  ·  provides  sensitivity  control  of 

PIR according to  the environment. 

Position Up"ON" · (Pulse=l)-High sensitivity for stable environments. 

Position  Down"OFF"-(Pulse=Auto)•Low  sensitivity  for  harsh 
environments. 

MW SENSITIVITY ADJUSTMENT 

Switch  3 of dipswitch  marked  "MW"  - provides  sensitivity  control  of 

Microwave detection according to  the  environment. 

Note: Brackets not included

 or supplied.