General specifications 

■Measurement block 

Comparison block specifications

 

 
 
 
 
 
 
 
 

Common specifications

 

 
4.Mounting 

4-1 Mounting 

1)Mounting the meter on mounting panel 

  Drill the hole as shown in Fig.1 through the mounting panel, then 

insert the meter into the mounting panel through the hole from 

the front. 

  Recommended panel thickness: 0.8 to 3.5mm 

 

 

 

 

 

 

 

 

 

  4-2 Connector connection 

1)Power supply connection 

    Connect the power supply between the zno.9 (0V) and No.10 (+24V) 

terminals on the lower connector. Use the meter at a power supply 

voltage of 24V DC+20%. (As this meter is not provided with a power 

supply switch, the meter is ready to operate just when the power 

is turned on.) 

2)Connect the input signal between the HI (No.1) and LO (No.2) 

terminals on the upper connector.  

 

 

 

 

Measurement function 

:Specify one Model from among DC voltage 

and current measurement Model Nos. 

Operation type 

:Double integral 

Input circuit 

:Single-ended 

Input bias current 

:2nA(TYP) 

Sampling speed 

:2.5 times/sec 

Noise rejection ratio 

:NMR40dB TYP (50/60Hz) 

Temperature 
characteristics 

:Offset displayed-value: 

Within ±0.3digit/℃ 

  Fullscale displayed-value 

Within ±0.3digit/℃ 

Overrange warning 

:”1999” flashes for input signal 

exceeding the maximum display. 

Fullscale variable 
range 

:100 to 1999 

Offset variable range 

:±1000 

Span 

:2000 counts 

Display 

:LEDs(Light Emitting Diodes, Numeric 

elements) 

Character height;8mm(red) 

Polarity display 

::”-” is automatically displayed when 

the measurement result is minus. 

External control 

 

:・Scaling function: 
    Set  by  the  multi-rotating  variable 

resistor on the front surface. 

・External hold: 
  0V signal or contact signal (shorting) 
・External start: 
  Positive pulse of +5V for more than 1ms 

from 0V or contact signal (open) 

・Decimal point: 
  The position of the decimal point can 

be freely set by the stud pin on the 
front surface.

 

Analog output 

:0 to ±2V 
  Load resistance; More than 1kΩ 

Control method 

:Analog comparator 

Comparison setting 
range 

: 100  to  +1999(for  both  high  and  low 

limits) 

  However for offset display, the offset 

value becomes the minimum value of the 
setpoint. 

Comparison setting 
accuracy 

:Setpoint ±2digit(23℃±5℃)(TYP) 

Setting 

: Set by selector switch. 
  Set  by  the  multi-rotating  variable 

resistors for both HI and LO. 

Comparison output 
relays 

:Relay output for HI and LO; 
  250V AC, 0.1A Max. Resistive load 

 

  120V AC 0.5A MAX.  Resistive load 

 

  28V DC 1A MAX.  Resistive load 
  Mechanical service life; 
  More than 5 million times 
  Electrical service life; 
  More than 100,000 times 
  (at rated load) 

Comparison operation 
indication 

:For both HI and LO; 
  Red LEDs on the front surface light. 

Comparison conditions  :For HI;   

High-limit setpoint≦Displayed value 

  For LO; 
  Low-limit setpoint> Displayed value 

Hysteresis 

:None 

Response 

:5ms(TYP) 

Dielectric strength 

:Between power supply terminal (0V) and 

input terminal (LO);  

For 1 min. at 500V DC  

Between input terminal (LO) and case; 

For 1 min. at 1500V AC 

Insulation resistance 

: Between  each  terminal  described 

above; More than 100MΩ at 500V DC 

Operating temperature/ 

humidity range 

:0 to 50℃/ 

35 to 85%RH(No-condensing) 

Power supply voltage 

:24V DC 

Allowable voltage 

variation range 

:24V DC±20% 

Consuming current 

:35mA(TYP)(At 24V DC) 

Dimensions 

:48(W)×24(H)×87(D)DIN size 

Weight 

:Approx. 55g(Only for the mainframe) 

Accessories 

:Instruction manual 1 copy 

  Connectors  2 pcs. 

  Scaling label  1 sheet 

Others 

:If you need to display engineering 

units, please contact us. 

Compliance standard 

:EN61326-1/2006 

  EMI:Class A      

EMS:Industrial locations 

  ※Cable length: 30m or less 

  ※In the case of DC drive DC power 

Supply port: DC connections 

between parts of equipment 

EN61010-1:2001 

Mounting environment 

:Mounting category Ⅱ 

  Pollution level 2 (IEC1010-1) 

Mounting altitude 

:Lower than 2000m 

Fuse 

:MC3/10. 125V, 0.3A 

  Quick blow type 

MODEL AM-212 Series                 

                                   

                              (2/4) 