background image

 

 

6-16-19, JINGUMAE, SHIBUYA-KU, TOKYO 150-0001, JAPAN 

TEL: +81-3-3400-6147    FAX: +81-3-3409-3156

 

 

2/3         

IM0874

-

00

 

5. Circuit Configuration

 

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 

6. How to Mount

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

It's  possible  to  install  close  adherence,  but  recommended  so 
that  6.5  mm-more  than  7  mm  may  be  opened  for  thermal 
radiation. 
It will be 6.5mm between the case body by the 29.5mm space. 

.

 

7. How to Connect to/Disconnect from 

DIN Rail

 

 
 
 

 

1) How to secure the socket 
Engage the hook on the rear upper 
side of the socket with the rail with 
the slider on the bottom side of the 
socket downward, and press the 
lower side of the socket in the arrow 
direction as shown in the drawing to 
secure the socket.

 

2) How to secure the main unit to 

the socket 

Position the main unit so that the 
characters in the front label can be 
read in the appropriate direction, 
press the main unit into the socket, 
and screw the main unit to secure it.

 

 

 
 
 
 
 
 
 
 

3) How to disconnect the main unit 

from the socket 

Loosen the screws that secure the 
main unit, and pull the unit out in a 
straight line.

 

4

) How to disconnect the socket 

Put a flat head screwdriver into 
the slider slot of the socket and 
pull the lower side of the socket 
in the arrow direction 

 while 

pulling the screwdriver in the 
arrow direction 

.

 

 

 
 
 
 

 
 
 
 

8. How to Connect

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 

Terminal 

No.

 

Sign

 

Description

 

 

INPUT

 

+

 

These terminals receive the 
specified input signals. 

 

-

 

 

NC

 

 

No connection

 

 

NC

 

 

No connection

 

 

OUTPUT1

 

+

 

Signals are provided in accordance 
with the input/output specifications.

 

 

12 

-

 

 

13 

POWER 

U(+)

 

Connect the rated voltage power 
supply.

 

 

14 

V(-)

 

 

 

* No line shall be connected to NC. 

 

9. How to Adjust Output

 

 
 
 

We have already performed output adjustment in 

accordance with your requests at your order. Therefore, no 
output adjustment is required if you operate this product 
within your requested specifications. If matching with devices 
to be connected or regular calibration is required, follow the 
steps below. 

For calibration, use signal sources (including a standard 

voltage/current generator) and measuring instruments 
(including a voltmeter and an ammeter) the tolerances of both 
of which are more than 10 times that of this product and wait 
for 30 minutes or more after turning on the power. 

Output adjustment is performed with the setting switch on 

the front side of this product. 

 

 

 
 
 
 
 
 
 
 

 

 
 
 

*

 

Please don't change a setting condition 

  (right side) of the selection switch 3 after shipping.

 

 

  How to adjust 

 

Set the selection switch 1 (SW SET) to ON. 

This action enables switch operation. 

 

Set the selection switch 2 (M OUT) to OFF. 

 

Set the selection switch 4 (ZS SEL) to ZERO. 

Use the UP or DOWN switch to adjust the output to 0% 
when a 0%-equivalent input is provided. 

 

Set the selection switch 4 (ZS SEL) to SPAN. 

Use the UP or DOWN switch to adjust the output to 100% 
when a 100%-equivalent input is provided. 

 

1:Switch 
    Enabled/Disabled 
2:Simulated output/ 

Output adjustment 

3:Unused*

 

4:Zero adjustment/ 

Span adjustment 