background image

 

 

6-16-19, JINGUMAE, SHIBUYA-KU, TOKYO 150-0001, JAPAN 

TEL: +81-3-3400-6147    FAX: +81-3-3409-3156

 

 

1/3         

IM0874

-

00

 

Operating Instructions 

WSP-ABS 

 
 
 
 
 
 

 

ABSOLUTE-VALUE

 

EXTRACTOR 

 

We thank you for purchasing the product manufactured by 

Watanabe Electric Industry Co., Ltd. Please use the product in 
accordance with this manual after confirming that the contents 
on the rating label of the product conform to the specifications 
you required. 

This instruction manual explains how to handle, connect, 

and adjust this product. 

We are sure that you will be satisfied with this product 

because this product has been manufactured and inspected in 
accordance with the strict quality control standards. In case of 
trouble such as damage during transportation, please contact 
your dealer or us as soon as possible. 

Package Includes

 

● Arithmetic and logic unit 1 unit

 

 

Socket                              1 piece

 

 

1. Product Outline

 

 
 
 

 

This equipment is a converter of the plug-in-shaped which 
receives analog signal with a polarity and outputs a signal 
proportional to its absolute value. 
For example, it outputs an ide10V signal in case of 
inp10V and inputting -10V.

 

 

2. Functions and Features

 

 
 
 

 

● It's possible to adjust zero and spans of output by UP or 

DOWN switch in the front. 

 

The output linearity of signal is an excellent. 

 

Realization of 5-year guarantee owing to long life design 

 

Universal power supply supported 

 

CE Marking compliance 

 

RoHS Directive compliance

 

 

3. Cautions

 

 
 
 

 

1) When this product is used as a CE Directive-compliant 

item: 

 

This product complies with Installation Category II, 

Pollution Degree 2, and Maximum Operating Voltage of 

300 volts required by CE Directive. Basic insulation is 
provided for insulation capability between power supply 
terminal and input

output of signals. Make sure that the 

insulation class of this product meets the required 
specification before installation. 

 

● Follow the definition that this product is designed to be 

installed in a control panel. 

● This product shall be used at an altitude equal to or 

below 2000 meters. 

● Appropriate space and creeping distance shall be 

provided. Inappropriate wiring may revoke compliance 
with CE Marking. 
CE Directive: Electromagnetic Compatibility Directive 

EMI    EN61000-6-4 
EMS    EN61000-6-2 

The wiring length should be not more than 
30 m. 

Low Voltage Directive    EN61010-1

 

           

RoHS

 

Directive    EN50581

   

 
 
 

● Insulation resistance: 

Among Input-primary output-secondary output-power 
supply terminal 
100 M ohms or more/500 V DC 

 

Withstand voltage: 

Among Input-primary output-secondary output-power 
supply terminal 
2000 V AC for 1 minute

 

 

2) Power supply 

 

Check the rating label. 

 

For rating: 100-240 V AC 

100-240 V AC±10% (50/60 Hz), 
approx. 5.5 VA   

  For rating: 24 V DC 
24 V DC±10%, approx. 100 mA 

 

For rating: 100-120 V DC 

100-120 V DC±10%, approx. 25 mA 

 
3) When handling 

 

When this product is connected to or disconnected from 

the socket, be sure to turn off the power and stop the 
input signal for safety. 

 

When a screw on this product is touched or the 

output control switch is operated, be sure to touch 
any metal object to release static electricity 
beforehand. 

 

4) Installation 

 

Be sure to use this product indoors. 

 

If this product is installed in a place with a lot of dust or 

metal particles, use a dust-proofing case with heat 
releasing measures to keep this product clean. 

 

Avoid vibration or shock to this product as much as 

possible. Failure to observe this may cause trouble. 

 

Install this product within the operating temperature 

range of –5 to 55 degrees C. 

 

Install this product with the operating humidity of 90% 

RH or less (no freezing, no condensation). 

 

Do not block the ventilation slot of this product. 

 

5) Wiring 

● Keep the power supply line, input line, and output line 

away from the noise sources, relay drive line, and high 
frequency line. 

 

Avoid bundling the line of this product together with the 

line of superimposed noise and holding the line in the 
same duct in which the line of superimposed noise is 
held. 
 

6) Caution other than the above 

 

It takes 30 minutes to assure full performance of this 

product even this product can be operated immediately 

after turning on the power.

 

 
 

4. Dimensional Drawing

 

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Reviews: