 1  Features

The suction unit 

SG-10

 is used to extract dental dust at the workplace and to extract 

polishing dust and fine blasting units.

Universal suction unit works with the low pressure principle

Single workbench suction unit

Power control is infinitely variable using the control element on the housing

(an external control element can be retrofitted, accessory item no.140408)

Modular filter system for different uses

Innovative filter concept, easy-to-replace filter system

Filter saturation display

Other filters available: from the activated carbon filter to the high-volume plaster 

pre-filter

Suitable for continuous operation

High-quality finish

Free from wear and maintenance-free

Recommended version for our fine blasting units

 2  Safety Symbols used in this Manual

Warning!

This is a warning of risk situations and dangers. 

Failure to observe this warning could be life-threatening. These warnings has to 

be observed.

Information!

This symbol draws your attention to specific features that has to be observed.

4

Summary of Contents for 140987

Page 1: ...t SG 10 Single Workbench Suction Unit USER MANUAL SG 10 Activated Carbon Version REF 140987 fig with accessory external speed regulator SG 10 Basic Version REF 140988 fig with accessory external speed...

Page 2: ...accidents as well as the precautions given in this user manual We are not liable for any damages which occur due to inappropriate usage or faulty operation of this device Make sure that anyone using t...

Page 3: ...ance 10 10 2 1 Replacing the filter 10 10 3 Repairs 11 10 4 Spare Parts 11 10 5 Service Hotline 0049 0 40 730 926 20 24 11 10 6 Scope of Delivery Accessories 12 10 6 1 Use of the Filter Extension Modu...

Page 4: ...fferent uses Innovative filter concept easy to replace filter system Filter saturation display Other filters available from the activated carbon filter to the high volume plaster pre filter Suitable f...

Page 5: ...osive atmosphere Do not apply suction to any liquids 4 Responsibility for Operation or Damage The responsibility for operating the device lies exclusively with the owner or user if said device is inco...

Page 6: ...ry potentiometer for fan control and a pilot lamp to indicate filter saturation on the housing Additionally the unit s modular structure permits operation with activated carbon and or a pre filter set...

Page 7: ...without proper ventilation Before start up be sure the device reaches room temperature 6 3 Storage The unit location is very important when it comes to workplace safety even if it is only to be set u...

Page 8: ...l is located on the left side of the housing Start the fan and set the desired level by turning the control element It can also be used to briefly stop the fan 3 Use the rocker switch to deactivate th...

Page 9: ...se contact our service department Full filter but red lamp does not glow Damaged lamp Please contact our service department Damaged differential pressure switch Empty filter but red lamp already glows...

Page 10: ...res only normal cleaning sponge damp cloth mild detergent and no further chemical additives 10 2 Maintenance The unit does not require any servicing Just make sure that the device is kept clean 10 2 1...

Page 11: ...ced when necessary but after no later than 4 to 6 months The filter cassette dust class M secondary filter should be replaced depending on its use recommendation use for no more than 12 months 10 3 Re...

Page 12: ...24 Accessories Item no Spare micro fine dust filterbag yellow small dust class M 1 set 4 pieces 611010 Spare filterbag for plaster white small class 1 class 2 1 set 4 pieces 611018 Spare micro fine du...

Page 13: ...please use the filter extension To do this open the fasteners on the right and the left take off the lid insert the filter extension and close the fasteners Insert the new filter e g plaster filterba...

Page 14: ...e pre filter filterbag dust class M long 340 mm and close the lid In order to replace the activated carbon filter while using the SG 10 please remove the activated carbon filter slot from the unit and...

Page 15: ...e with the unit by unauthorized persons 11 Technical Data SG 10 basic version Item no 140988 SG 10 activated carbon version Item no 140987 Voltage 220 240 V 50 60 Hz Power consumption 0 75 A Output 11...

Page 16: ...ilter 2 REF 140424 Module activated carbon filter with filter 3 REF 140980 Suction unit SG 10 base 4 REF 310035 Identification plate serial number etc 5 REF 610074 Spare micro fine dust filterbag yell...

Page 17: ...Module Activated Carbon Filter REF 140424 1 REF 140426 Filter casing cpl SG 10 2 REF 140427 Filter frame cpl SG 10 3 REF 140435 Spare filter cassette dust class F cpl 4 REF 140436 Spare activated car...

Page 18: ...tect the environment prevent environmental pollution and improve the recycling of raw materials the European Commission adopted a directive that requires the manufacturer to accept the return of elect...

Page 19: ...sere Zustimmung ver ndert wird This is to confirm that the above mentioned machine complies with the described EU guidelines This declaration becomes invalid if the machine is modified without our app...