background image

 

 

- 4 -

 

 

Danger! Do not touch the tool when it is rotating or coming to a stop! 

Be sure to follow the manufacturer’s guidelines for the maximum 

permissible speed of the rotating tools used. 

 

 

 

Take the following precautions before starting work: 

• 

Wear eye protection 

• 

Use a protective visor 

 

1.4  Handpiece block 

 

This rotary tool features electronically controlled overload protection

If an excessive load blocks the handpiece, the motor switches off automatically and the 

red LED flashes. 

The  handpiece  stops  if  the  chuck  is  open,  and  the  electronics  also  cut  out  if  the  tool 

starts working accidentally. 

 

1.5  Responsibility for operation and damage 

 

The responsibility for operating the unit lies exclusively with the owner or user if the said 

unit  is  incorrectly  serviced,  maintained  or  altered  by  persons  not  employed  by  an 

accredited dealer or if the unit is used in a manner contrary to its specified purpose. 

The  unit  must  be  maintained  and  operated  in  accordance  with  this  user  manual. 

Wassermann  Dental-Maschinen GmbH  is  not  responsible for  damage  arising  from  the 

non-observance of these instructions. 

Guarantee and responsibility provisions contained in the sales and supply conditions of 

Wassermann Dental-Maschinen GmbH are not extended by these instructions. 

 

Product responsibility lapses if the equipment is altered by 

unauthorized third parties or if non-original parts are installed. Use 

only original WASSERMANN replacement parts. 

 

!

 

 

 

!

 

 

 

!

 

 

 

 

Summary of Contents for HSM-500

Page 1: ...WASSERMANN DENTAL MASCHINEN GMBH User manual HSM 500 bench top rotary tool...

Page 2: ...ully before you start work and operate the unit according to the recommended guidelines Please ensure that all persons operating the equipment have read and understood this user manual Keep this user...

Page 3: ...Use Application 7 4 Before you start 7 4 1 UNPACKING TRANSPORT 7 4 2 CONTENTS 8 5 Switch functions 8 5 1 POWER SWITCH 8 5 2 CONTROL ROCKER SWITCH 8 5 3 DIRECTION ROCKER SWITCH 8 5 4 SPEED CONTROL KNOB...

Page 4: ...observe this warning could be life threatening These warnings must be observed Information This symbol draws your attention to specific features which must be observed 1 3 Safety guidelines Configurin...

Page 5: ...peration and damage The responsibility for operating the unit lies exclusively with the owner or user if the said unit is incorrectly serviced maintained or altered by persons not employed by an accre...

Page 6: ...al is accessible at all times and has been read and understood 2 Care and maintenance 2 1 Maintenance The equipment should be cleaned at regular intervals to ensure trouble free operation It requires...

Page 7: ...to the left Use a brush to clean the shaft and then lubricate the chuck and the bore with two drops of oil each Insert the chuck by hand Make sure that the chuck mechanism is still open Insert the ch...

Page 8: ...acking Transport Open the cartons remove the packing materials and carefully lift out the instrument and accessories Check that the accessories are correct When transporting the unit use appropriate p...

Page 9: ...ains switch lights green 5 2 CONTROL rocker switch This switch enables you to control the tool by hand or knee 5 3 DIRECTION rocker switch The DIRECTION rocker switch controls the direction of rotatio...

Page 10: ...to the left you will feel and hear it clicking into place Warning Always turn the handpiece casing up to the stop 6 Installation 6 1 Installing the motor mains and foot switch cables At the rear of t...

Page 11: ...tion Tighten the motor cable swivel nut by turning it clockwise by hand Warning Do not use pliers 7 Start up Check that the rotating tool has been inserted up to the stop Set the CONTROL switch to foo...

Page 12: ...ystem error Send unit in for service If the above recommendations do not solve the problem contact your dental depot or our Service department 8 2 Technical data Voltage switchable 220 240 V 50 60 Hz...

Page 13: ...o be used Responsibility for the product is voided if altered by unauthorized persons or if inappropriate components are installed 9 Warranty The warranty period for our equipment is 12 months If faul...

Page 14: ...ert wird This is to confirm that the above mentioned machine complies with the described EC rules This declaration becomes invalid if the machine is modified without our approval Cette machine est con...

Page 15: ...14...

Page 16: ...WASSERMANN Dental Maschinen GmbH Rudorffweg 15 17 D 21031 Hamburg Tel 49 0 40 730 926 0 Fax 49 0 40 730 37 24 e mail info wassermann dental com Internet http www wassermann dental com...