Serial Programming Commands
11-10
DuraLine™ 2D Imagers
Number of Beeps -
Good Read
*1
BEPRPT
Range 1 - 9
BEPRPT#
Reread Delay
Short (500 ms)
DLYRRD500
*Medium (750 ms)
DLYRR750
Long (1000 ms)
DLYRRD1000
Extra Long (2000 ms)
DLYRRD2000
User-Specified
Reread Delay
Range 0 - 30,000 ms
DLYRRD#####
Good Read Delay
*No Delay
DLYGRD0
Short Delay (500 ms)
DLYGRD500
Medium Delay (1000 ms)
DLYGRD1000
Long Delay (1500 ms)
DLYGRD1500
User-Specified
Good Read Delay
Range 0 - 30,000 ms
DLYGRD#####
Trigger Mode
*Manual/Serial Trigger
TRGMOD0
Read Time-Out
(0 - 300,000 ms) *0
TRGSTO####
Manual Trigger, Low Power
TRGMOD2
Low Power Time-Out Timer
( 0 - 300 seconds) *120
TRGLPT###
Scan Stand
Scan Stand Mode
TRGMOD4
Scan Stand Symbol
FNC3
Presentation Presentation
Mode
TRGMOD3
Presentation LED
Timer
LEDs Off
TRGPCK0
*LEDs On
TRGPCK1
Presentation Sen-
sitivity
Range 0-20 (*1)
TRGPMS##
Hands Free Time-
Out
Range 0 - 300,000 ms
TRGPTO#####
#
Selection
Setting
* Indicates default
Serial
Command
# Indicates a
numeric entry
Page
Summary of Contents for 2D
Page 1: ...P r o d u c t R e f e r e n c e G u i d e Wasp DuraLine 2D Imager Dura...
Page 24: ...Terminal Interfaces 2 12 DuraLine 2D Imagers NOTES...
Page 54: ...Data Editing 4 8 DuraLine 2D Imagers NOTES...
Page 110: ...Symbologies 6 50 DuraLine 2D Imagers NOTES...
Page 122: ...Imaging Commands 7 12 DuraLine 2D Imagers NOTES...
Page 140: ...OCR Programming 8 18 DuraLine 2D Imagers NOTES...
Page 152: ...Utilities 10 6 DuraLine 2D Imagers NOTES...
Page 180: ...Serial Programming Commands 11 28 DuraLine 2D Imagers NOTES...
Page 192: ...A 8 DuraLine 2D Imagers NOTES...
Page 196: ...B 4 DuraLine 2D Imagers OCR Programming Chart a e d g c h t l Discard Save r...
Page 197: ...Programming Chart User s Guide B 5 Programming Chart A C B F E D 1 0 2 3...
Page 199: ......
Page 200: ...2004 12 04...