Washtech CD180 Operator'S Manual Download Page 7

7/13/2022

7

Machine Positioning

Unpack machine, check for damage and complete delivery. 

Install machine on sound waterproof self-draining floor and use adjustable feet to level 
machine. 

NOTE: Failure to level the machine correctly may result in leaking during the cycle, 
overflowing from the door sill, poor hygiene through the wash tank not being able to 
drain correctly.

Allow room for detergent to one side of machine or in adjacent cupboard. 20 litre container 
requires approximately 450H x 250W x 350D, but smaller containers are available from many 
suppliers.

Ventilation

10 m³/min = 170 l/sec – refer installation diagram – extraction via connected ducts or 
overhead canopy. 

Inlet Water Operation

Incoming water should be within the following standard requirements:

Temperature:   65 °C.

Connection:   20 mm (3/4” BSP) male. 

NOTE: Flush supply line before connection. Poor quality supply or excessive water 
hardness may affect performance or damage machine – filtration and/or softening is 
recommended. 

Flow rate:   minimum 20 litres per minute.

Water Consumption: 5 litres per minute.

Pressure:   between 200 and 350 kPa.

NOTE: This machine is  not equipped with a rinse booster pump and relies on incoming 
water pressure to drive the rinse cycle. 
NOTE: If above 350 kPa fit pressure limiter valve (LPV). Do not use small diameter plastic 
supply lines.

Backflow prevention:   Dual Check Valve (DCV) fitted standard. 

Water Quality Requirements

The incoming water should also be within the following parameters:

Hardness 

ppm 

pH

min 

20 

7

max 

100 

8

Ions 

Cl-

SO

4

Fe          Mn

Cu            Cl

2

Max mg/L 

100       400 

0.1          0.5 

0.05        0.1

NOTE: Levels above or below the stated requirements can be expected to increase 
component wear and reduce the expected useful life of the dishwasher. If in doubt, it is 
best to consult a water specialist and have the incoming water professionally tested and 
treated if necessary.

Installation Instructions

Washtech CD180 Operator Manual

Summary of Contents for CD180

Page 1: ...CD180 RACK CONVEYOR OPERATOR MANUAL...

Page 2: ...lity The alteration of machine operation design or the replacement of parts not approved by the manufacturer may void warranties and approvals This machine is intended for commercial use only This mac...

Page 3: ...on Instructions 9 Installation Checklist 10 Installation Troubleshooting 11 Operator Use Guide 12 Operator Care Prewash Zone 13 Operator Care Wash Zone 14 Operator Care Curtains 15 Operator Troublesho...

Page 4: ...nformation found on the labels of detergent containers and Material Safety Data Sheets Use protective eyewear and clothing if decanting containers Hot Water Do not put hands in wash water which may be...

Page 5: ...7 13 2022 5 Installation Diagram CD180R Installation Part CD180R Date 22 05 2022 Version 3 A Washtech CD180 Operator Manual...

Page 6: ...7 13 2022 6 Installation Diagram CD180L Installation Part CD180L Date 22 05 2022 Version 3 A Washtech CD180 Operator Manual...

Page 7: ...Poor quality supply or excessive water hardness may affect performance or damage machine filtration and or softening is recommended Flow rate minimum 20 litres per minute Water Consumption 5 litres pe...

Page 8: ...uncertain please consult a chemical specialist for assistance in selecting the right chemicals and calibrating machine settings to suit this along with your unique site conditions and requirements Was...

Page 9: ...NG CHEMICALS CHEMICAL NAME CONTAINER NO LEAKS PRIMED CALIBRATED DETERGENT RINSE FLUID MACHINE OPERATION MACHINE RUNNING CORRECTLY MULTIPLE CYCLES RUN NO ISSUES CHEMICAL DOSAGE CORRECT CORRECTLY FLOWIN...

Page 10: ...rinse results we recommended this is solved by installing a rinse pump rather than compensating by reducing chemical dosages Other equipment in the kitchen has needed filters or has scale Due to the h...

Page 11: ...e the rack is pushed fully into the inlet to engage pawl drive Repeat for all consecutive racks NOTE Pumps and conveyor will stop operating if the machine is left idle for 2 minutes To restart the pum...

Page 12: ...ump Inlet Filter 3 and Scrap Tray 1 to the machine Weekly Cleaning To be done in conjunction with Daily cleaning Remove Lower Wash Arms 4 lift up to unhook the arm and then withdraw Remove Upper Wash...

Page 13: ...let Filter 12 and Scrap Trays 10 to the machine Weekly Cleaning To be done in conjunction with Daily cleaning Remove Lower Wash Arms 8 lift up to unhook the arm and then withdraw Remove Upper Wash Arm...

Page 14: ...from the hoods can be regulated with the adjusting T bar screws under the deflector baffles at the vents When the machine is installed under a canopy the baffles can be opened up widely drop baffle ab...

Page 15: ...ACHINE FOOD RESIDUE ON WARE FILM SPOTS ON WARE DETERGENT RESIDUE GREASY FILM NO FIZZ WET WASHWARE SCALE BUILD UP IN MACHINE FILTERS ON OTHER EQUIPMENT PAWL DRIVE NOT OPERATING CRASHING SOUND AGAINST D...

Page 16: ...7 13 2022 16 Schematic Diagram CD180 Schematic Diagram Part 260104 Date 11 05 2022 Version 1 A Washtech CD180 Operator Manual...

Page 17: ...7 13 2022 17 Accessories CD180 Accessories Part CD180 ACW Date 24 05 2022 Version 1 A Washtech CD180 Operator Manual...

Page 18: ...7 13 2022 Washtech CD180 Operator Manual 18 Notes...

Page 19: ...7 13 2022 Washtech CD180 Operator Manual 19 Notes...

Page 20: ...vice 1300 264 217 Parts 1300 263 107 Tel 03 9518 3888 Fax 03 9518 3818 E mail sales moffat com au web www moffat com au ISO9001 All Washtech products are designed and manufactured by Washtech using th...

Reviews: