Power

Electrical supply required is 3p/25A 415V 50Hz via switched outlet adjacent to machine. 

NOTE: Equipment contains dangerous voltages and can be hazardous if installed or                                     
operated incorrectly. Non –compliance with warnings or failure to follow the 
instructions contained in this manual can result in loss of life, severe personal injury or 
serious damage to property.

Chemical

Detergent and rinse aid pumps are not supplied with the CD100. We recommend you consult 
your chemical supplier and/or a local chemical expert for their recommended detergent and 
Rinse Fluid injector pumps.

NOTE: Commercial detergents can be hazardous – read instructions, store safely and 
handle with care. Care needs to be taken when changing chemicals, ensuring that the 
detergent is not accidentally connected to the rinse fluid inlet line.
NOTE: If uncertain, please consult a chemical specialist for assistance in selecting the 
right chemicals and calibrating machine settings to suit this along with your unique site 
conditions and requirements. 

Waste

40mm connection required to point B as specified on install diagram. An S-trap must be fitted 
on each of these points.

NOTE: Either copper or P.V.C. may be used for the waste connection – P.V.C. is more 
resistant to some harsh detergents. Some authorities however suggest that copper is 
required because the machine rinses at up to 90°C. It is important to note that rinse 
water mixes with the 65°C wash water before discharge and then flows into the sink 
trap where the water is further cooled before entering the drainage plumbing. We 
recommend consulting your local authority to ensure your site remains compliant.

Installation Checklist

Complete attached Installation Checklist to ensure machine is installed and running correctly, 
and operator is familiar with operating procedures.

Installation Instructions

Washtech CD120L Operator Manual

Summary of Contents for CD120

Page 1: ...CD120 RACK CONVEYOR OPERATOR MANUAL...

Page 2: ...lity The alteration of machine operation design or the replacement of parts not approved by the manufacturer may void warranties and approvals This machine is intended for commercial use only This mac...

Page 3: ...iagram 6 Installation Instructions 8 Installation Checklist 9 Installation Troubleshooting 10 Operator Use Guide 11 Operator Care Wash Zone 12 Operator Care Curtains 13 Operator Troubleshooting 14 Sch...

Page 4: ...formation found on the labels of detergent containers and Material Safety Data Sheets Use protective eyewear and clothing if decanting containers Hot Water Do not put hands in wash water which may be...

Page 5: ...4 26 2022 5 Installation Diagram CD120L Installation Part CD120L Date 22 04 2022 Version 3 A Washtech CD120L Operator Manual...

Page 6: ...ction Poor quality supply or excessive water hardness may affect performance or damage machine filtration and or softening is recommended Flow rate minimum 20 litres per minute Water Consumption 5 lit...

Page 7: ...ertain please consult a chemical specialist for assistance in selecting the right chemicals and calibrating machine settings to suit this along with your unique site conditions and requirements Waste...

Page 8: ...HEMICALS CHEMICAL NAME CONTAINER NO LEAKS PRIMED CALIBRATED DETERGENT RINSE FLUID MACHINE OPERATION MACHINE RUNNING CORRECTLY MULTIPLE CYCLES RUN NO ISSUES CHEMICAL DOSAGE CORRECT CORRECTLY FLOWING IN...

Page 9: ...essure also impacts rinse results we recommended this is solved by installing a rinse pump rather than compensating by reducing chemical dosages Other equipment in the kitchen has needed filters or ha...

Page 10: ...ush into the inlet zone of the machine NOTE Pumps and conveyor will stop operating if the machine is left idle for 2 minutes To restart the pump and conveyor simply feed a new rack into the inlet of t...

Page 11: ...p Inlet Filter 12 and Scrap Trays 10 to the machine Weekly Cleaning To be done in conjunction with Daily cleaning Remove Lower Wash Arms 8 lift up to unhook the arm and then withdraw Remove Upper Wash...

Page 12: ...Purpose of Curtains To keep the heat inside the zones of the machine To stop water splashing from one zone to another This prevents wash and rinse water mixing If this happens the water quality will b...

Page 13: ...E BUILD UP IN MACHINE FILTERS ON OTHER EQUIPMENT LIMIT SWITCH ACTIVATED WASH ARM NOT FITTED PROPERLY MACHINE STOPS REFILLS CONSTANTLY Likely cause Possible cause For issues most likely due to incorrec...

Page 14: ...4 26 2022 14 Schematic Diagram CD120 Schematic Diagram Part 260100 Date 18 01 2022 Version 1 A Washtech CD120L Operator Manual...

Page 15: ...4 26 2022 15 Accessories CD100 Accessories Part CD100 ACW Date 18 02 2020 Version 1 A Washtech CD120L Operator Manual...

Page 16: ...vice 1300 264 217 Parts 1300 263 107 Tel 03 9518 3888 Fax 03 9518 3818 E mail sales moffat com au web www moffat com au ISO9001 All Washtech products are designed and manufactured by Washtech using th...

Reviews: