Installation manual
15
5.2.3
Outputs
Connect the power supply (e.g. 24V DC) for the external liquid supplies to 9 and 10. If an internal power supply (from
the machine) is being used, it can be taken from 1 (N) and connected to 9 and from 2 (L) and connected to 10. Max
load on the outputs 0.5 A.
Signals for external liquid supplies 1-5 are connected to 12-16 where connector:
12 = Signal 1
13 = Signal 2
14 = Signal 3
15 = Signal 4
16 = Signal 5
fig.6236B
6M14
6F01
6R01
6F02
Other programs
Signal 1
-
Pre-wash
Pre-wash
Pre-wash
Pre-wash
Signal 2
Main wash
Main wash
Main wash
Main wash
Main wash
Signal 3
Softener
Softener
Softener
Softener
Softener
Signal 4
Mop last rinse
Desinfection
Pr 1 last rinse
Mainwash
-
Signal 5
Bleach
Bleach
Bleach
Bleach
Bleach