RECOMMENDATIONS

The following recommendations are designed to ensure that the device always functions reliably:

• Never open the casing! To do so would expose you to the risk of an electric shock. Should repairs prove necessary, leave

them to qualified service personnel.

• Avoid dust and high moisture levels, direct sunlight and extremely high or low temperature. 

• Safeguard the device from excessive vibration. Always place the unit on a stable and horizontal surface.

• See to adequate ventilation. The device should not be placed on soft surfaces (carpet, cushions, etc.). When mounting 

it in a rack, make sure that the rear and lateral cooling vents remain unobstructed.

• Avoid leaving the unit near radiators or other objects producing heat.

• Internal components should only be adjusted or cleaned by qualified service technicians. Ensure no object or liquid 

penetrates the device through its cooling vents.

• When replacing a fuse make sure you fit in one of identical value!

Have the device examined by a qualified service technician in the following cases:

• the mains lead or mains switch have been damaged,

• objects or liquids have penetrated the device,

• it has been exposed to excessive moisture,

• malfunctions or abnormal operating conditions have occurred,

• the device has been dropped or the casing damaged.

Congratulations on the purchase of the new Warwick amplifier head/combo. Please read through these

instructions  before  connecting  and  operating  the  device.  If  you  keep  to  the  guidelines  set  out  in  this

manual, you will soon be able to appreciate the quality of this new Warwick amplifier. Please keep this

instruction booklet handy in case you need to consult it again. Please send the PASSPORT to the address

indicated therein.

HINTS

- This apparatus shall not be exposed dripping or splashing and that no objects filled with liquids, such as vases, shall 

be placed on the apparatus. 

- This apparatus should be connected to a MAINS socket outlet with a protective earthing connection.

- Mains plug or appliance connector shall be used as the disconnect device, so mains plug or appliance connector should

always remain readily operable.

- If the apparatus shows any malfunction, immediately disconnect the main power cord from the mains socket.

- Do only operate effects pedals in-between the instrument and the amplifier, as these devices are not designed for the 

supplied load of an effects loop.

- Remove the plug whenever changing a fuse.

- Only ever replace a fuse with another of the same type. Never bridge defective fuses.

- Make sure the top and bottom of the device are properly ventilated and that the vents are not blocked.

- Do not subject the device to excessive vibration or hard jolts as these could damage the device.

- Don't undertake repairs yourself.

- Only allow the case to be opened by qualified personnel. (Remove the plug).

- Repairs should only be undertaken by qualified personnel.

SHOULD YOU FIND YOURSELF ONE DAY WONDERING: "WHY IS THERE NO SOUND COMING OUT?"

please check:

- all stub cables,

- all connections of these cables

and proceed anew by following the guidelines of the chapter GETTING STARTED. Possibly the problem reveals to be an

operational error.

Summary of Contents for PROFET 3.3

Page 1: ...OFFICIAL WARWICK AMP OWNER MANUAL ...

Page 2: ...Languages English 05 Suffix Technical Data and Schematic Diagram 65 OFFICIAL WARWICK AMP OWNER MANUAL FOR PROFET 3 3 AND PROFET 5 2 I IN ND DE EX X ...

Page 3: ...ENGLISH 5 ...

Page 4: ...cian No vessel filled with liquids such as vases shall be placed on top of the unit This symbol wherever it appears alerts you to the presence of dangerous non insulated voltage inside the case Risk of electric shock This symbol wherever it appears indicates to important operating and maintenance instruct ions in this user manual Please read the manual Weee Nr DE93670540 This recycling logo inform...

Page 5: ...ou keep to the guidelines set out in this manual you will soon be able to appreciate the quality of this new Warwick amplifier Please keep this instruction booklet handy in case you need to consult it again Please send the PASSPORT to the address indicated therein HINTS This apparatus shall not be exposed dripping or splashing and that no objects filled with liquids such as vases shall be placed o...

Page 6: ...wer up delay When the unit is switched on the SPEAKER OUT sockets are activated with a slight delay to protect the loudspeakers Short circuit In the event of a short circuit at the power amp outputs this feature prevents the output stage transistors from destruction by quickly reducing current Direct current DC This circuit continuously monitors the power amp output for direct current and protects...

Page 7: ...or turning the amplifier on and off MAINS IN AC Terminal with integrated fuse compartment for connecting the amplifier to the current network GROUNDLIFT Switch isolates the earth connection from the ground of the signal Should several devices be simul taneously connected to earth by the same conductor as well as via line connections a so called hum loop might appear In this case operate GROUND LIF...

Page 8: ...for turning the amplifier on and off MAINS IN AC Terminal with integrated fuse compartment for connecting the amplifier to the current network GROUNDLIFT Switch isolates the earth connection from the ground of the signal Should several devices be simul taneously connected to earth by the same conductor as well as via line connections a so called hum loop might appear In this case operate GROUND LI...

Page 9: ...30Hz Bright 8dB 3kHz 14dB 16kHz Contour 20dB 20Hz 10dB 300Hz 12dB 10kHz Compressor adjustable Headphone 200 ohms min Direct Out 0dB 600 ohms Effects Loop mono serial send 0dB 600 ohms return 0dB 10k ohms Switches Groundlift DI pre post Speaker Out jack and lockable coaxial 300W 4 ohms Profet 3 3 500W 4 ohms Profet 5 2 THD 0 1 Weight 8 5 kg Profet 3 3 10 0 kg Profet 5 2 Dimensions 19 483 x 90 x 350...

Page 10: ...EAKERS PROFET 3 3 5 2 Speaker Set up Quantity 4 16 ohms Cabinets 2 8 ohms Cabinets 1 6 ohms Cabinet 1 4 ohms Cabinet Note The minimum load of the power amplifier is 4 ohms ProFet Cabinet WCA 211 Pro 8 ohms Cabinet WCA 115 Pro 8 ohms 66 ...

Page 11: ...67 ...

Page 12: ...ete na webov ch stránkách HYPERLINK http www warwick de Máte li nûjaké technické dotazy pi te na support warwick de Headquarters Warwick GmbH Co Music Equipment KG Gewerbepark 46 08258 Markneukirchen Germany E Mail info warwick de Branch China Warwick Music Equipment Shanghai Ltd Co Shanghai Waigaoqiao Free Trade Zone Shanghai 200131 P R China E Mail info warwick cn Branch UK Warwick Music Equipme...

Reviews: