background image

s a n d p i p e r p u m p

.

c o m

Model T30  

Food Processing Metallic  
Design Level 1

Warren Rupp, Inc.

A Unit of IDEX Corporation

800 N. Main St.,  

Mansfield, Ohio 44902 USA  

 

Telephone 419.524.8388

Fax 419.522.7867

SANDPIPERPUMP.COM

© Copyright 2017 Warren Rupp, Inc.

All rights reserved

Certified Quality

ISO 9001 Certified 

I

SO 14001 Certified

SERVICE & OPERATING MANUAL

Original Instructions

1: PUMP

 SPECS

2: INST

AL

 & OP

3: EXP

 VIEW

4: 

AIR END

5: WET END

6: W

ARRANTY

 

Tel:  866-777-6060 
Fax: 866-777-6383

Springer Pumps, LLC

Website: www.springerpumps.com 

Int'l: +001 267 404 2910

Summary of Contents for SANDPIPER T30 Series

Page 1: ...19 524 8388 Fax 419 522 7867 SANDPIPERPUMP COM Copyright 2017 Warren Rupp Inc All rights reserved Certified Quality ISO 9001 Certified ISO 14001 Certified SERVICE OPERATING MANUAL Original Instruction...

Page 2: ...flushed after each use to prevent damage In freezing temperatures the pump should be completely drained between uses Before pump operation inspect all fasteners for loosening caused by gasket creep Re...

Page 3: ...arts List Material Codes SECTION 4 AIR END 11 Air Distribution Valve Assembly Air Valve with Stroke Indicator Assembly Pilot Valve Assembly Intermediate Assembly SECTION 5 WET END 17 Diaphragm Drawing...

Page 4: ...Wetted Material S Stainless Steel Diaphragm Check Valve Materials A PTFE FDA Nitrile PTFE D FDA Santoprene FDA Santoprene 9 FDA Nitrile PTFE Check Valve Seat S Stainless Steel T PTFE Pump Pump Check D...

Page 5: ...evated temperatures 220 F 104 C 35 F 37 C Maximum and Minimum Temperatures are the limits for which these materials can be operated Temperatures coupled with pressure affect the longevity of diaphragm...

Page 6: ...6 299 12 62 321 4 22 107 3 34 85 2 34 59 16 72 425 15 75 400 DISCHARGE PORT 4 SANITARY TRI CLAMP FERRULE SUCTION PORT 4 SANITARY TRI CLAMP FERRULE 10 12 257 5 06 129 12 00 305 6 00 152 8 84 225 4 91 1...

Page 7: ...15 105 DISCHARGE PORT 3 RAISED FACE ANSI STYLE 150 LB FLANGE OR 80 DIN 10 BAR FLANGE SUCTION PORT 3 RAISED FACE ANSI STYLE 150 LB FLANGE OR 80 DIN 10 BAR FLANGE 4 91 125 8 84 225 12 00 305 6 00 152 5...

Page 8: ...oking also initiates the reciprocating shifting stroking or cycling action of the pump The suction diaphragm s movement is mechanically pulled through its stroke The diaphragm s inner plate makes cont...

Page 9: ...air supply can be reduced by using a point of use air dryer Air Inlet And Priming To start the pump slightly open the air shut off valve After the pump primes the air valve can be opened to increase...

Page 10: ...air flow Deadhead system pressure meets or exceeds air supply pressure Increase the inlet air pressure to the pump Pump is designed for 1 1 pressure ratio at zero flow Does not apply to high pressure...

Page 11: ...45 42 37 37 9 ITEM NO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 Torque 90 in lbs 10 N m Composite Repair Parts Drawi...

Page 12: ...0 Ball Check PTFE 4 3 070 006 170 Bushing Intermediate included in item 5 2 4 095 110 313 Pilot Valve Assy w aluminum center epoxy coated 1 095 110 110 Pilot Valve Assy Stainless Center 1 5 114 024 31...

Page 13: ...Nitrile 368 Food Grade EPDM 371 Philthane Tuftane 374 Carboxylated Nitrile 375 Fluorinated Nitrile 378 High Density Polypropylene 379 Conductive Nitrile 408 Cork and Neoprene 425 Compressed Fibre 426...

Page 14: ...reverse order starting with step 3 Note Sleeve and spool 1 B set is match ground to a specified clearance sleeve and spools 1 B cannot be interchanged Air Valve Assembly Parts List Use w Aluminum cent...

Page 15: ...Parts List Item Part Number Description Qty 4 095 110 313 Pilot Valve Assembly 1 4 A 095 095 313 Valve Body 1 4 B 755 051 000 Sleeve With O rings 1 4 C 560 033 360 O ring Sleeve 6 4 D 775 055 000 Spoo...

Page 16: ...g 30 discard Step 3 Remove bushing plunger 7 inspect for wear and replace if necessary with genuine parts Step 4 Remove O Ring 26 inspect for wear and replace if necessary with genuine parts Step 5 Li...

Page 17: ...iperpump com Model T30 Metallic 14 Diaphragm Service Drawing Non Overlay 31 25 15 13 6 27 16 28 10 14 24 24 5 WET END Tel 866 777 6060 Fax 866 777 6383 Springer Pumps LLC Website www springerpumps com...

Page 18: ...r diaphragm plate through the center hole of the diaphragm Note Most diaphragms are installed with the natural bulge out towards the fluid side S05 S07 and S10 non metallic units are installed with th...

Page 19: ...rements to verify conformance 5 YEAR Limited Product Warranty Warren Rupp Inc Warren Rupp warrants to the original end use purchaser that no product sold by Warren Rupp that bears a Warren Rupp brand...

Page 20: ...ssors T15B1SDSWTS600 T15B1SSSWTS600 T15B1SDSSTS600 T15B1SSSSTS600 T15B1SSTWTS600 T15B1SSTSTS600 TA1 NG1SS TA25 NG1SS TA1 1 2 NG1SS TA40 NG1SS T30B1SASWTS600 T30B1SDSWTS600 T30B1SASSTS600 T30B1SDSSTS60...

Reviews: