Warren rupp Sandpiper S1F Service & Operating Manual Download Page 23

s1fmdl1sm-rev1218

sandpiperpump

.

com

Model S1F Metallic • 

23

Solenoid Shifted Air Valve

Solenoid Shifted Air Valve Parts List

(Includes all items used on Composite Repair Parts List except as 

shown)

 

Item  Part Number 

Description 

Qty

33 

893.097.000 

Solenoid Valve, NEMA4  

1

34 

219.001.000 

Solenoid Coil, 24VDC 

1

 

219.004.000 

Solenoid Coil, 24VAC/12VDC 

1

 

219.002.000 

Solenoid Coil, 120VAC 

1

 

219.003.000 

Solenoid Coil, 240VAC 

1

35 

241.001.000 

Connector, conduit 

1

 

241.003.000 

Conduit Connector with 

1

 

 

Suppression Diode (DC Only)

36 

170.045.330 

Capscrew, Hex HD 5/16-18 x 1.25 

4

37 

618.050.150 

Plug  

2

38 

171.053.115 

Capscrew, Socket Head                                4

II 2G EEx m c T5
II 2D c IP65 T100°C

IEC EEX m T4

For Explosion Proof Solenoid Coils used in North America and 

outside the European Union.

34 

219.009.001 

Solenoid Coil, 120VAC 60 

H

z

 1

 

219.009.002 

Solenoid Coil, 240VAC 60 

H

z

                        

 

219.009.003 

Solenoid Coil, 12VDC 

1

 

219.009.004 

Solenoid Coil, 24VDC 

 

219.009.005 

Solenoid Coil, 110VAC 50 

H

z

 

 

219.009.006 

Solenoid Coil, 230VAC 50 

H

z

 

1

 

Note: Item 35 (Conduit Connector) is not required

 

For ATEX Compliant Solenoid Coils used in the European Union 

34 

219.011.001      Solenoid Coil, Single mounting 12 VDC,  

 

 

3.3W / 267mA 

1

 

219.011.002      Solenoid Coil, Single mounting 24 VDC,  

 

 

3.3W / 136mA 

1

 

219.011.003      Solenoid Coil, Single mounting 110/120 VAC,  

 

 

3.4W / 29mA 

1

 

219.011.004      Solenoid Coil, Single mounting 220/240 VAC,  

 

 

3.4W / 15mA 

1

 

Note: Item 35 (Conduit Connector) is not required

*Special Conditions For Safe Use

A fuse corresponding to its rated current (max. 3*I

rat

 according IEC 

 

60127-2-1) or a motor protecting switch with short-circuit and thermal instantaneous  

tripping (set to rated current) shall be connected in series to each solenoid as short  

circuit protection. For very low rated currents of the solenoid the fuse of lowest  

current value according to the indicated IEC standard will be sufficient. The fuse may 

be accommodated in the associated supply unit or shall be separately arranged. 

The rated voltage to the fuse shall be equal to or greater than the stated rated  

voltage of the magnet coil. The breakage capacity of the fuse-link shall be as high 

as or higher than the maximum expected short circuit current at the location of 

the installation (usually 1500 A). A maximum permissible ripple of 20% is valid for  

all magnets of direct-current design. 

*

II 2G EEx 

m

 c II T5

II 2D c IP65 T100°C

Compressed Air Temperature Range:

 Maximum Ambient Temperature 

to plus 50°C

Solenoid Shifted Air 

 

Distribution  Valve  Option

Warren Rupp’s solenoid shifted, air distribution valve option utilizes electrical 

signals to precisely control your SANDPIPERs speed. The solenoid coil is 

connected to a customer - supplied control. Compressed air provides the 

pumping power, while electrical signals control pump speed (pumping rate).

Operation

The Solenoid Shifted SANDPIPER has a solenoid operated, air distribution 

valve in place of the standard SANDPIPERs pilot operated, air distribution 

valve. Where a pilot valve is normally utilized to cycle the pump’s air distribution 

valve, an electric solenoid is utilized. As the solenoid is powered, one of the 

pump’s air chambers is pressurized while the other chamber is exhausted. When 

electric power is turned off, the solenoid shifts and the pressurized chamber 

is exhausted while the other chamber is pressurized. By alternately applying 

and removing power to the solenoid, the pump cycles much like a standard 

SANDPIPER pump, with one exception. This option provides a way to precisely 

control and monitor pump speed.

Before Installation

Before wiring the solenoid, make certain it is compatible with your system 

voltage.

37

33

34

35

33

37

36

38

#2 Terminal 

Neutral 

(Negative)

#1 Terminal 

Power 

(Positive)

3rd Terminal 

for ground.

Wiring 

Diagram

6: OPTIONAL

Summary of Contents for Sandpiper S1F

Page 1: ...93 99 89 7 44 188 98 81 76 4 19 106 43 5 31 135 6 73 171 07 3 54 89 81 4X 38 9 53 MOUNTING HOLES BOTTOM VIEW 12 03 305 56 41 10 32 1 22 30 96 13 0 18 SUCTION PORT 1 NPT 5 00 127 00 9 09 230 80 1 63 41...

Page 2: ...use of non OEM replacement parts will void or negate agency certifications including CE ATEX CSA 3A and EC1935 compliance Food Contact Materials Warren Rupp Inc cannot ensure nor warrant non OEM parts...

Page 3: ...0 C to 50 C 20 C to 100 C T5 T100 X Ambient Temperature Range C Process Temperature Range C 20 C to 60 C 20 C to 150 C 1 Per CSA standards ANSI LC6 2018 US Canadian Technical Letter R14 G Series Natur...

Page 4: ...posite Repair Parts Drawing Composite Repair Parts List Material Codes SECTION 4 AIR END 11 Air Distribution Valve Assembly Air Valve with Stroke Indicator Assembly Pilot Valve Assembly Intermediate A...

Page 5: ...Ex h IIC T5 225 C T2 Ga II 1D Ex h IIIC T100 C T200 C Da I M1 Ex h I Ma H S C 6 00 II 2 G Ex h IIC T5 225 C T2 Gb II 2 D Ex h IIIC T100 C T200 C Db A H S A C Y 0 6 00 II 2 G Ex h ia IIC T5 Gb II 2 D E...

Page 6: ...chlorinated aromatic hydrocarbons 200 F 93 C 10 F 23 C Nitrile General purpose oil resistant Shows good solvent oil water and hydraulic fluid resistance Should not be used with highly polar solvents...

Page 7: ...41 10 32 1 22 30 96 5 13 130 18 12 88 327 09 SUCTION PORT 1 NPT 1 NPT EXHAUST PORT 5 00 127 00 8 16 207 19 4X R 16 3 97 6 75 171 45 3 87 98 35 9 09 230 80 1 63 41 28 5 00 6 39 162 31 AIR INLET 1 2 NP...

Page 8: ...ical dimensions are needed Dimensional Drawings 10 25 260 35 5 13 130 18 13 3 18 2 00 50 80 2 00 50 80 4 18 106 29 8 37 212 71 16 04 407 30 1 NPT EXHAUST PORT 4 64 117 73 3 87 98 17 3 93 99 89 7 44 18...

Page 9: ...e check valve and into the outer fluid chamber Suction side stroking also initiates the reciprocating shifting stroking or cycling action of the pump The suction diaphragm s movement is mechanically p...

Page 10: ...causing the pump to cycle erratically or stop operating Water in the air supply can be reduced by using a point of use air dryer Air Inlet And Priming To start the pump slightly open the air shut off...

Page 11: ...oint of use air drier Clogged manifolds Clean manifolds to allow proper air flow Deadhead system pressure meets or exceeds air supply pressure Increase the inlet air pressure to the pump Pump is desig...

Page 12: ...Gaskets Retaining Rings Air Valve Sleeve and Spool Set and Pilot Valve Assembly 476 194 354 Wet End Kit Santoprene Diaphragms Balls and Polyethylene Seats 476 194 360 Wet End Kit Nitrile Diaphragms B...

Page 13: ...Tapered 1 518 175 156W Welded Raised Face 150 1 ANSI Flanged Manifold 1 518 175 110 Manifold Suction 1 518 175 110E Manifold Suction 1 BSP Tapered 1 518 175 110W Welded Raised Face 150 1 ANSI Flanged...

Page 14: ...Food Grade Nitrile 368 Food Grade EPDM 371 Philthane Tuftane 374 Carboxylated Nitrile 375 Fluorinated Nitrile 378 High Density Polypropylene 379 Conductive Nitrile 408 Cork and Neoprene 425 Compresse...

Page 15: ...4 Note Pumps equipped with these Valve Assemblies are not ATEX compliant Air Distribution Valve Servicing See repair parts drawing remove screws Step 1 Remove hex cap screws 1 F Step 2 Remove end cap...

Page 16: ...020 360 O Ring 10 1 E 165 127 157 Cap End 2 1 F 170 032 330 Hex Head Capscrew 1 4 20 x 75 8 Air Valve Assembly Parts List 1 031 183 001 Air Valve Assembly 1 Consists of all components above except 1 F...

Page 17: ...alve Body 1 1 B 031 139 000 Sleeve and Spool Set 1 1 C 132 029 552 Bumper 2 1 D 560 020 360 O Ring 10 1 E 165 127 110 Cap End 2 1 F 170 032 115 Capscrew 8 Note cannot be used with integral muffler Opt...

Page 18: ...9 360 O Ring 2 For Pumps with PTFE Coated Hardware 1 031 146 002 Air Valve Assembly 1 1 J 710 015 308 Screw Self Tapping 4 includes all other items on 031 146 000 above For Pumps with Piped Exhaust 1...

Page 19: ...e O Rings 4 C and 4 E Reassemble in reverse order Pilot Valve Assembly Parts List Item Part Number Description Qty 4 095 110 000 Pilot Valve Assembly 1 4 A 095 095 157 Valve Body 1 4 B 755 052 000 Sle...

Page 20: ...ger 2 21 560 001 360 O Ring 2 25 620 022 115 Plunger Actuator 2 26 675 042 115 Ring Retaining 2 28 720 010 375 Seal Diaphragm Rod 2 Intermediate Assembly Drawing Step 1 Remove plunger actuator 25 from...

Page 21: ...oprene and Elastomer diaphragms Diaphragm Service Drawing Non Overlay Diaphragm Service Drawing with Overlay One Piece Bonded Diaphragm Service Drawing 14 Available For Field Conversion From Overlay T...

Page 22: ...y together Torque values are called out on the exploded view Repeat procedure for second side assembly Allow a minimum of 15 minutes to elapse after torquing then re torque the assembly to compensate...

Page 23: ...of lowest current value according to the indicated IEC standard will be sufficient The fuse may be accommodated in the associated supply unit or shall be separately arranged The rated voltage to the...

Page 24: ...N809 2012 Pumps and Pump Units for Liquids Common Safety Requirements to verify conformance 5 YEAR Limited Product Warranty Warren Rupp Inc Warren Rupp warrants to the original end use purchaser that...

Page 25: ...Series MSA Series U Series F Series T Series Conductive plastic pump models with integral muffler S Series PB Series Tranquilizer surge suppressors Hazardous Location Applied I M1 Ex h I Ma II 1 G Ex...

Reviews: