background image

SERVICE & OPERATING MANUAL

Model S15 Non-Metallic Design Level 2

520-193-000   9/02

Engineering Data and Temperature Limitations ...................................................................... 1

Explanation of Pump Nomenclature ........................................................................................ 2

Performance Curve, Model S15 Non-Metallic Design Level 2 ............................................... 3

Dimensions: S15 Non-Metallic ................................................................................................. 4

Metric Dimensions: S15 Non-Metallic ...................................................................................... 5

Dimensions: S15 Non-Metallic with RuppGUARD™ Spill Prevention ..................................... 6

Metric Dimensions: S15 Non-Metallic with RuppGUARD™ Spill Prevention ......................... 7

Principle of Pump Operation .................................................................................................... 8

Installation and Start-up ........................................................................................................... 8

Air Supply ................................................................................................................................. 8

Air Valve Lubrication ................................................................................................................. 8

Air Line Moisture ...................................................................................................................... 8

Air Inlet and Priming ................................................................................................................. 8

Between Uses .......................................................................................................................... 8

Installation Guide ...................................................................................................................... 9

Important Safety Information ................................................................................................. 10

Material Codes ....................................................................................................................... 10

Troubleshooting ...................................................................................................................... 11

Warranty ................................................................................................................................. 11

Composite Repair Parts Drawing .......................................................................................... 12

Overlay Option Drawing ........................................................................................................ 12

Composite Repair Parts List .................................................................................................. 13

RuppGUARD™ Spill Prevention Option for Virgin PTFE Equipped Pumps ......................... 14

RuppGUARD™ Spill Prevention Repair Parts List ............................................................... 14

RuppGUARD™ Spill Prevention Concept ............................................................................. 15

RuppGUARD™ Spill Prevention Option Diaphragm Servicing ............................................ 15

Filling RuppGUARD™ Chambers with Liquid ....................................................................... 15

RuppGUARD™ Spill Prevention Option for TPE Equipped Pumps ..................................... 16

RuppGUARD™ Spill Prevention Repair Parts List ............................................................... 16

RuppGUARD™ Spill Prevention Concept with TPE Diaphragms ........................................ 17

RuppGUARD™ Spill Prevention Option with TPE Diaphragm ............................................. 17

Air Distribution Valve Assembly Drawing ............................................................................... 18

Main Air Valve Assembly Parts List ....................................................................................... 18

Air Distribution Valve Servicing .............................................................................................. 19

Air Distribution Valve with Stroke Indicator Options .............................................................. 20

Air Distribution Valve with Stroke Indicator Parts List ........................................................... 20

Air Distribution Valve with Stroke Indicator Servicing ........................................................... 21

Solenoid Shifted Air Valve Drawing ........................................................................................ 22

Solenoid Shifted Air Valve Parts List ...................................................................................... 22

Solenoid Shifted Air Distribution Valve Option ....................................................................... 23

Pilot Valve Assembly Drawing ................................................................................................ 24

Pilot Valve Assembly Parts List .............................................................................................. 24

Pilot Valve Servicing ............................................................................................................... 25

Diaphragm Service Drawing, Non-Overlay .......................................................................... 26

Diaphragm Service Drawing, with Overlay ........................................................................... 26

Diaphragm Servicing .............................................................................................................. 27

Overlay Diaphragm Service .................................................................................................. 27

Pumping Hazardous Liquids .................................................................................................. 28

Converting the pump for piping the exhaust air .................................................................... 28

Exhaust Conversion Drawing ................................................................................................ 28

Converted Exhaust Illustration .............................................................................................. 28

Modular Check Valve Servicing ............................................................................................. 29

Modular Check Valve Drawing ............................................................................................... 29

Dual Port Option Drawing ...................................................................................................... 30

Dual Porting Options .............................................................................................................. 31

Dual porting of both suction and discharge ends of the pump ............................................. 31

Single porting of the suction and dual porting of the pump discharge .................................. 31

Dual porting of the suction and single porting of the pump discharge ................................. 31

RuppTech® Leak Detection Options Drawing ...................................................................... 32

RuppTech® Electronic Leak Detector Installation ................................................................ 32

RuppTech® Mechanical Leak Detector Installation .............................................................. 32

RuppTech® Pulse Output Kit Drawing .................................................................................. 33

RuppTech® Pulse Output Kit Option ..................................................................................... 33

Exhaust Port or Auxiliary Muffler Setup ................................................................................. 33

Integral Muffler Setup ............................................................................................................. 33

Table of Contents

CE

U.S. Patent #

400,210;

5,996,627;

6,241,487

Warren Rupp®, Inc. • A Unit of IDEX Corp. • Box 1568, Mansfield, OH 44901-1568 USA • Tel: (419)  524-8388 • Fax (419)  522- 7867 • www.warrenrupp.com

Summary of Contents for sandpiper ii S15

Page 1: ...s List 18 Air Distribution Valve Servicing 19 Air Distribution Valve with Stroke Indicator Options 20 Air Distribution Valve with Stroke Indicator Parts List 20 Air Distribution Valve with Stroke Indi...

Page 2: ......

Page 3: ...lic Design Level 2 Ball Valve Air Powered Double Diaphragm Pump ENGINEERING PERFORMANCE CONSTRUCTION DATA CE U S Patent 5 851 109 5 996 627 400 210 6 241 487 Other U S Patents Applied for Materials Ma...

Page 4: ...oated Aluminum K PTFE Coated Aluminum L PTFE Coated Aluminum with PTFE Coated Hardware R Epoxy Coated Aluminum with PTFE Coated Hardware Porting Options A ANSI Flange D DIN Flange 7 Dual Porting ANSI...

Page 5: ...S Gallons per minute Liters per minute 340 320 300 280 260 240 220 200 180 160 140 120 100 80 60 40 20 0 100 90 80 70 60 50 40 30 20 10 0 BAR PSI Head 1 2 3 4 5 6 7 0 30 20 25 10 15 5 9 1 6 7 6 3 4 5...

Page 6: ...7 8 Dimensions S15 Non Metallic Dimensions in Inches Dimensional tolerance 1 8 Note Porting Flanges are also avaible with PN10 40mm DIN bolting configuration Dimension Standard Pump Pulse Output Kit M...

Page 7: ...tric Dimensions S15 Non Metallic Dimensions in Millimeters Dimensional tolerance 3mm 606mm Dimension Standard Pump Pulse Output Kit Mesh Muffler A B 167mm 322mm 202mm 357mm 225mm 380mm Note Porting Fl...

Page 8: ...imensions S15 Non Metallic with RuppGUARD Spill Prevention 28 5 8 B 15 1 4 A Dimension Standard Pump A B 6 9 16 7 15 16 Pulse Output Kit Mesh Muffler 12 11 16 14 1 16 8 13 16 14 15 16 Note Porting Fla...

Page 9: ...age 7 Metric Dimensions S15 Non Metallic with RuppGUARD Spill Prevention 728 mm B A Dimension Standard Pump A B 167mm 202mm Pulse Output Kit 322mm 357mm Mesh Muffler 225mm 380mm Note Porting Flanges a...

Page 10: ...The flexible hose reduces vibration and strain to the pumping system A surge suppressor is recommended to further reduce pulsation in flow AIR SUPPLY Air supply pressure cannot exceed 100 psi 7 bar C...

Page 11: ...ssor 020 050 000 Filter Regulator 020 050 001 Lubricator 020 047 007 Air Dryer Available from Warren Rupp CAUTION The air exhaust should be piped to an area for safe disposition of the product being p...

Page 12: ...600 Virgin PTFE 601 PTFE Bronze and moly filled 602 Filled PTFE 603 Blue Gylon 604 Virgin PTFE 607 Envelon 606 Injected molded PFA 610 Encapsulated Silicon 611 Encapsulated Viton 632 Neoprene Hytrel...

Page 13: ...r Corrective Action Remove muffler screen clean or de ice and reinstall Refer to the Air Exhaust section of your pump SERVICE MANUAL What to Check Pumped fluid in air exhaust muffler Corrective Action...

Page 14: ...for PVDF RuppGUARD Santoprene Diaphragms PTFE Overlay Diaphragms PTFE Pumping Diaphragms PTFE Balls and PTFE Seals 031 141 000 ASSEMBLY AIR VALVE without Encapsulated Muffler Muffler Cap and six scre...

Page 15: ...c HD 3 8 16 x 2 75 4 171 053 308 Capscrew Soc HD 3 8 16 x 2 75 4 14 196 147 520 Chamber Outer 2 196 147 552 Chamber Outer 2 15 196 148 156 Chamber Inner 2 196 148 307 Chamber Inner 2 196 148 309 Chamb...

Page 16: ...hamber Spill Prevention 2 44 286 076 600 Diaphragm Pumping 2 45 518 131 520 Manifold 2 replaces 518 130 xxx 518 131 520E Manifold 40mm DIN 2 518 131 552 Manifold 2 replaces 518 130 xxx 518 131 552E Ma...

Page 17: ...lugs items 49 The spill prevention chambers are filled through the exposed ports 4 Apply air pressure to the air distribution valve Install safety clip item 1 N into the smaller unthreaded hole in one...

Page 18: ...places 518 130 xxx 518 131 55E Manifold 40mm DIN 2 46 538 022 110 Nipple Pipe 4 538 022 308 Nipple Pipe 4 47 560 078 611 O Ring 8 48 618 003 110 Plug Pipe 4 618 003 308 Plug Pipe 4 49 618 025 110 Plug...

Page 19: ...14 The discharge manifolds and elbows can now be removed 3 Remove the top two boss plugs items 49 The spill prevention chambers are filled through the exposed ports 4 Apply air pressure to the air dis...

Page 20: ...28 550 Muffler 1 1 G 560 020 360 O Ring 8 1 H 675 044 115 Ring Retaining 2 1 J 710 015 115 Screw Self tapping 4 For pumps equipped with PTFE Coated Hardware 1 031 140 002 Air Valve Assembly 1 Includes...

Page 21: ...scratches or other contaminates Remove the sleeve if needed and replace both the sleeve and spool with a new sleeve and spool set item 1 A STEP 3 Reassemblyoftheairvalve Install one end cap item 1 E w...

Page 22: ...098 147 Cap End 2 1 F 530 028 550 Muffler 1 1 G 560 020 360 O Ring 8 1 H 675 044 115 Ring Retaining 2 1 J 710 015 115 Screw Self Tapping 4 1 K 210 008 330 Clip Safety 1 1 M 560 029 360 O Ring 2 For P...

Page 23: ...spool part of item 1 A from the sleeve Be careful not to scratch or damage the outer diameter of the spool Wipe spool with a soft cloth and inspect for scratches or wear Inspect the inner diameter of...

Page 24: ...il 24VAC 12VDC 1 219 002 000 Solenoid Coil 120VAC 1 219 003 000 Solenoid Coil 240VAC 1 58 241 001 000 Connector conduit 1 59 170 061 115 Capscrew Hex HD 3 8 16 x 1 75 4 60 618 052 506 Plug 2 For Explo...

Page 25: ...a pilot valve is normally utilized to cycle the pump s air distribution valve an electric solenoid is utilized As the solenoid is powered one of the pump s air chambers is pressurized while the other...

Page 26: ...rts List ITEM PART NUMBER DESCRIPTION QTY 2 095 088 000 Pilot Valve Assembly 2 A 095 081 551 Body Pilot Valve 1 2 B 135 033 506 Bushing 2 2 C 675 055 115 Ring Spiral Retaining 2 2 D 770 049 175 Spacer...

Page 27: ...Step 3 Re assembly of the pilot valve First install a spiral retaining ring to one end of the pilot valve body Install one bushing making sure the step side faces toward the wiper Apply a light coatin...

Page 28: ...520 193 000 9 02 Model S15 Non Metallic Design Level 2 Page 26 Diaphragm Service Drawing Non Overlay Diaphragm Service Drawing with Overlay...

Page 29: ...to compensate for stress relaxation in the clamped assembly Step 5 Installing the diaphragm assemblies to the pump Make sure the bumper item 6 is installed over the diaphragm rod Thread the stud of t...

Page 30: ...product source is at a higher level than the pump flooded suction condition pipe the exhaust higher than the product source to prevent siphoning spills See illustration 3 at right CONVERTINGTHE PUMP F...

Page 31: ...cuts abrasive wear or embedded materials Replace as needed Inspect the check balls items 3 for wear abrasion or cuts on the spherical surface The check valve seats items 36 should be inspected for cu...

Page 32: ...9 02 Model S15 Non Metallic Design Level 2 Page 30 Dual Port Option Drawing 1 ANSI STYLE FLANGE CONNECTION FOUR 62 HOLES ON A 3 88 BOLT CIRCLE 1 ANSI STYLE FLANGE CONNECTION FOUR 62 HOLES ON A 3 88 B...

Page 33: ...n the Dual Porting Drawing Single porting of the suction and dual porting of the pump discharge To convert the pump from the standard single suction and single discharge porting configuration to a dua...

Page 34: ...ak detectors remove the bottom NPT pipe plug on the visual sight tube item 53 Insert leak detector into the pipe tee item 52 RuppTech LEAK DETECTION OPTION B MECHANICAL Follow instructions found elsew...

Page 35: ...control devices such as a PLC The Pulse Output Kits mount directly onto the Muffler Cap on the Air Distribution Valve Assembly or onto the Air Distribution Valve Assembly when the threaded exhaust po...

Page 36: ......