background image

7

Level Controls - IOM 200 VACUUM BREAKER                            200__IOM_RevC_0618

  FACTORY SERIAL 

NUMBER LABEL

INFORMATION PRESENT ON TYPE 200 

PART NUMBER & SERIAL NUMBER

Information

Symbol(s)

Location

Notes

Part number 

P/N

On spring chamber

• On Factory Serial Number Label attached to spring chamber.

Serial Number

SERIAL NO.

On spring chamber and 
valve body

• On Factory Serial Number Label attached to spring chamber.
• Sales order number only stamped on valve body end connection.*
   * Number stamped using approximately 1/8 inch tall characters

SERVICE

Information

Symbol(s)

Location

Notes

Maximum
pressure rating

Maximum

Pressure

On spring chamber

• On Factory Serial Number Label attached to spring chamber.

Maximum
temp. rating

Maximum

Temperature

On spring chamber

• On Factory Serial Number Label attached to spring chamber.

VALVE ATTRIBUTES

Information

Symbol(s)

Location

Notes

Body material

On vacuum 
breaker

• If the factory applied paint is black and the adapter body is cast in
  one piece the body material is iron.
• If the factory applied paint is black and the adapter body is made 
    of three sections welded together the body material is steel.
• If there is no factory applied paint present and the adapter body 
    is made of three sections welded together the body material
    is stainless steel. 

INFORMATION PRESENT ON TYPE 200 VACUUM BREAKER 

    

 

There is information present on each vacuum breaker ranging in importance from the part number and serial number to the 

color of the paint and casting numbers. This information is important for identifying the vacuum breaker, installing it correctly, 
and obtaining parts. An example of the current factory serial number label used on Type 200 vacuum breakers is shown 

here. The accompanying table identifies the information present and where to find it on the vacuum breaker. There may also 
be other casting numbers and foundry marks present that do not provide useful information. Customer specific tagging may 
also present. The labels or plates used, and information present, on Warren Controls other product lines or older vacuum 
breakers may be different, contact the factory for details.

Summary of Contents for 200

Page 1: ...perience PRODUCT OVERVIEW to apply sound safety and operational practices which may not be covered herein In applications where Warren Controls Inc furnished equipment is to be integrated with a proce...

Page 2: ...R TRANSPORTATION IMMEDIATELY NOTIFY YOUR SALES ORGANIZATION OF ANY DAMAGED GOODS UPON RECEIPT DO NOT ATTEMPT TO MOVE OR DISTURB THE VACUUM BREAKER FURTHER SO PHOTOS MAY BE TAKEN IF THE SHIPPING CONTAI...

Page 3: ...rs tanks with steam blankets produce additional liquid as the steam condenses The C 313 Overflow Trap traps and relieves this condensate through its internal pilot without the steam blanket escaping O...

Page 4: ...ERATION TYPE 200 VACUUM BREAKER When no vacuum is present the vessel pressure acts on the vacuum breaker s discholder pressing the disc into the seat sealing the tank s pipeline s contents inside When...

Page 5: ...Finish Pad are also suitable for cleaning the seat Clean the seat with a circumferential motion around its diameter not with a longitudinal motion across its length For vacuum breakers with an integra...

Page 6: ...moved from the piping or tank for the adjustment procedure 2 Remove capscrews from spring chamber 3 Remove spring chamber from valve body 4 Loosen jamnuts on stem until disc is not in contact with sea...

Page 7: ...in one piece the body material is iron If the factory applied paint is black and the adapter body is made of three sections welded together the body material is steel If there is no factory applied pa...

Page 8: ...9GXX000 4 150FLG 020013GXX000 6 150FLG 020015GXX000 8 150FLG 020017GXX000 10 150FLG 020019GXX000 12 150FLG 020020GXX000 STEEL 2 300FLG 020009HXX000 4 300FLG 020013HXX000 6 300FLG 020015HXX000 8 300FLG...

Page 9: ...020009HXX001 4 300FLG 020013HXX001 6 300FLG 020015HXX001 8 300FLG 020017HXX001 10 300FLG 020019HXX001 12 300FLG 020020HXX001 2 Type 200 has stainless steel discholder standard 200 WITH TEFLON DISC AN...

Page 10: ...cannot be set to open at a particular vacuum The vacuum values presented in the table are for reference only AIR RELIEF CAPACITIES WEIGHTS For dimensions see drawing 0200032510 TYPE 200 VACUUM BREAKE...

Page 11: ...that does not open to relieve a vacuum in a tank or close when the vacuum is relieved allowing the contents to escape and damage surrounding equipment and can also cause damage to the stem A damaged o...

Page 12: ...14 1 DISC HOLDER 7 1 STEM GUIDE 15 1 DISC REBUILD KIT FOR TYPE 200 VACUUM BREAKER WITH INTEGRAL SEAT AND DUAL SPRING SIZE 10 12 INCH EFFECTIVE DATE 9 26 2008 SEE DWG 0200032510 ITEM QTY DESCRIPTION I...

Page 13: ...RING 14 1 DISC HOLDER 5 1 STEM 15 1 DISC 7 1 STEM GUIDE 17 1 SEAT RING 9 1 CONNECTING PIN REBUILD KIT FOR TYPE 200 VACUUM BREAKER WITH REPLACEABLE SEAT AND DUAL SPRING SIZE 10 12 INCH EFFECTIVE DATE 9...

Page 14: ...14 2600 Emrick Blvd Bethlehem PA 18020 USA 800 922 0085 www warrencontrols com DRAWING 0200032510...

Page 15: ...15 Level Controls IOM 200 VACUUM BREAKER 200__IOM_RevC_0618 NOTES...

Page 16: ...2600 EMRICK BLVD BETHLEHEM PA 18020 USA 800 922 0085 WWW WARRENCONTROLS COM DEPENDABLE RUGGED PRECISION CONTROL VALVES AND ACCESSORIES 200_IOM_RevC_0618...

Reviews: