background image

 

  

Tension control system X2DRV 

29/08/2012 

 

X2DRV

 

Installation & Operation Manual

  

Page 2 of 5 

 

Ratings:  

 

Main Supply Voltage (V)

 

24V DC +/- 5%

 

Output 

4A with Anti Residual 

Operating  T°C 

-10°C to 50°C no Condensation 

Compliance 

 

 

 

General information: 

Control chassis should be kept clear of all areas where foreign material, dust, grease, or all might affect the operation of the control. 
Installation must be made in accordance with the instructions found in this manual. Failure to do so may damage the Driver. 
 
This driver supports the following Warner brakes : TB’s, ATT’s, MPB’s, MPC’s. POB’s, POC’s and MTB’s brakes cannot be driven by this device.  
 

Installation instructions: 
 

Hardware Pin Out: 
 

 

BK1+ 

Power Output 

Brake 1  

 

Integrated Anti-residual control. Voltage or Current controlled. 

BK1- 

Power Output 

Brake 1 Output –  
 

BK2+ 

Power Output 

Brake 2   
Integrated Anti-residual control. Voltage or Current controlled. 

BK2- 

Power Output 

Brake 2 Output –  
 

 

ON1 

Analog input 

Full power : 24VDC applied to brake 1 
Active low / GND: NPN type Input 

OFF1 

Analog input 

Power Off brake 1 : 0V applied to brake 1 with anti-residual 
Active low /GND: NPN type Input 

Gnd 

Ground 

 

ON2 

Analog input 

Full power : 24VDC applied to brake 2 
Active low /GND: NPN type Input 

OFF2 

Analog input 

Power Off brake 2 : 0V applied to brake 2 with anti-residual 
Active low /GND: NPN type Input 

10 

Gnd 

Ground 

 

 

11 

InBK1 

Analog input 

Brake 1 Input signal control. 
Selectable: 0/+10V DC or 4/20mA. 

12 

Gnd 

Ground 

 

13 

Ana1 

Analog input 

Brake 1 Auxiliary input : To compensate Brake1 signal in Open Loop control 
Selectable: 0/+10V DC or 4/20mA. 
Teachable Span (item 9 page 4). 

14 

Gnd 

Ground 

 

15 

10V 

Power out 

External interface Power Supply. 10VDC, 100mA Output 
Used to Power an external potentiometer to get an Open Loop control (local torque 
adjust) 

16 

Gnd 

Ground 

 

 

17 

InBK2 

Analog input 

Brake 2 Input signal control. 
Selectable: 0/+10V DC or 4/20mA. 

18 

Gnd 

Ground 

 

19 

Ana2 

Analog input 

Brake 2 Auxiliary input : To compensate Brake2 signal in Open Loop control 
Selectable: 0/+10V DC or 4/20mA. 
Teachable Span (item 9 page 4). 

20 

Gnd 

Ground 

 

21 

10V 

Power out 

External interface Power Supply. 10VDC, 100mA. 
Used to Power an external potentiometer to get an Open Loop control (local torque 
adjust) 

22 

Gnd 

Ground 

 

 

23 

24V 

Power supply 

24VDC Power supply Input 

24 

GND 

Ground 

GROUND 

 

 

 

 

 

Reviews: