![Warner Electric MCS-836 Service & Installation Instructions Download Page 5](http://html1.mh-extra.com/html/warner-electric/mcs-836/mcs-836_service-and-installation-instructions_873120005.webp)
5
Special Function
Motion Detector (Retriggerable or integrating one-shot):
This function provides a state change of the output device
when the input signal to the photoelectric control is changing
at a constant rate. When the input signal decreases in
frequency or stops completely, the output will reverse states.
Note:
Time t7 must be longer than the light or dark transition
time of the photoelectric input.
The response of the output module to the photoelectric input
(beam complete or beam break) is dependent on the mode of
operation selected for the photoelectric amplifier.
Note:
The timing potentiometers are not calibrated and the
minimum time may be less or the maximum time more than
the specified timing ranges.
(L)
(D)
t7
t7
Light
Dark
Pull-In
Drop Out
Photoelectric
Input
Output State
Warner Electric • 800-825-9050
P-241-78
®
DIST. AUTORIZADO
MEX (55) 53 63 23 31
QRO (442) 1 95 72 60
MTY (81) 83 54 10 18
[email protected]