background image

3

Warner Electric • 800-234-3369

P-239-31

Specifications:

Input power:

• MCS-805-1 120/230VAC ± 10%,

50/60Hz, single phase.

• MCS-805-2 120/230VAC ± 10%,

50/60Hz, single phase

Output:

MCS-805-1

35-75VDC, 0.40 amps

MCS-805-2

35-75VDC, 0.40 amps

Switching inputs:
(external to control, supplied by customer)

• DC switching: single pole, single throw.

Minimum contact rating 1 amp, 120 VDC.

• AC switching: single pole, single throw.

Minimum contact rating 1 amp, 120 VAC.

Ambient temperatures:

-20° to 150°F (-29° to 65°C)

Circuit protection: (fusing)

3/4 Amps, 250V Slow Blow, 3AG

Adjustments:

Release band adjustment (via internal poten-
tiometer)
MCS-805-2 only: Torque adjust (via external
potentiometer)

Wiring Entrance:

Two 7/8" diameter conduit entrance holes
located on the bottom and on the top of the
control chassis.

Reorder Information

Model

Part No.

MCS-805-1

6090-448-006

MCS-805-2

6090-448-007

Mounting

Any vertical, horizontal, or angled surface is suit-
able for mounting the MCS-805-1 or MCS-805-
2. Follow these procedures to mount your con-
trol:

a. Remove the front cover by removing the top

retaining screws.

b. Set the control on the mounting surface and

mark for the four mounting holes in accor-
dance with dimensions.

c. Install and tighten the four screws.

The control is now ready to be wired.

To avoid injury (or even death),

always make certain all power is off before
attempting to install this control or any elec-
trical equipment. Do not touch the board if
power is applied.

®

DIST. AUTORIZADO

MEX (55) 53 63 23 31
QRO (442) 1 95 72 60

MTY (81) 83 54 10 18
[email protected]

Summary of Contents for MCS-805-1

Page 1: ...Installation Instructions P 239 31 MCS 805 Series Clutch Brake Controls DIST AUTORIZADO MEX 55 53 63 23 31 QRO 442 1 95 72 60 MTY 81 83 54 10 18 ventas industrialmagza com ...

Page 2: ...s set by adjusting the control at the time of brake installation These controls are factory set for 60 volts output The MCS 805 1 and MCS 805 2 controls oper ate from 120 230VAC single phase input power Switching may be provided on either the AC or DC side of the control The MCS 805 1 and the MCS 805 2 have an internal adjustment potentiometer that is use for the release band adjustment The MCS 80...

Page 3: ...nce Two 7 8 diameter conduit entrance holes located on the bottom and on the top of the control chassis Reorder Information Model Part No MCS 805 1 6090 448 006 MCS 805 2 6090 448 007 Mounting Any vertical horizontal or angled surface is suit able for mounting the MCS 805 1 or MCS 805 2 Follow these procedures to mount your con trol a Remove the front cover by removing the top retaining screws b S...

Page 4: ...oosen locking nut on the adjustment potentiometer Turn the potentiometer adjusting screw to the maxi mum counterclockwise position Slowly turn the adjustment screw clockwise until the brake armature disengages from the magnet If the usual autogap spring is used this will normally cause the armature to separate approximately 1 32 from the magnet If the autogap is not used an external release force ...

Page 5: ...tion 1 2 3 4 5 6 7 8 9 AC INPUT 120 230 VAC 50 60 Hz Brake S1 GND DC Switching Jumper if not used 1 2 3 4 120 VAC 1 2 3 4 230 VAC 1 2 3 4 5 6 7 8 9 AC INPUT 120 230 VAC 50 60 Hz Brake S1 GND DC Switching Closed brake released Open brake in tq adj mode 1 2 3 4 1 2 3 4 120 VAC 230 VAC S1 S1 S1 Open brake engaged S2 Closed brake released or tq adj mode per S1 DIST AUTORIZADO MEX 55 53 63 23 31 QRO 44...

Page 6: ...r maintenance Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you Warner Electric Inc s obligation under this warranty is limited to the repair or replacement of the defective product and in no event shall Warner Electric Inc be liable for consequential indirect or incidental damages of any kind incurred by reason of the manufactur...

Reviews: