background image

6.

Set Overheat limit to protect your 

floor.

Please note, the 

Tempo 

will only 

allow you to set a temperature 

2°C/4°F lower than the Overheat 

limit

 30°F

  

7.

Set an offset value to calibrate 

the temperature reading of your 

thermostat sensors

0°F

The thermostat is not controlling the 

temperature 

Ensure that the 

Program Slide

 is in the run position (lowest point) and that the 

Mode 

Slide

 control (bottom) is in the manual or program positions. 

Floor sensor error 

If you see the floor sensor error icon          or “ - - “ on the screen it means that your 

thermostat has been unable to detect the temperature of the floor. Please contact 

Warmup. 

Overheat 

If you see the overheat icon          this means that your floor has become too hot and 

the heating has been suspended. Please contact Warmup. 

Low battery 

The low battery icon      will display when the battery needs to be replaced. The 

thermostat must be connected to the mains electricity supply in order to work, it is not 

designed to be used with an intermittent power supply. If the battery is not installed 

then your thermostat will not be able to maintain the clock time if power is lost.

Heating starts too early

 If your heating is coming on too early, then this may be because the Adaptive Learning 

function is turned on. This function allows your thermostat to learn how long it will take 

to heat up to ensure it is the correct temperature at the start of the comfort periods. 

See “installer settings” section of this guide. 

Incorrect calibration

Your thermostat should not need any calibration, however if you would like to apply an 

offset to the temperature settings see the “

installer settings

” section. 

No mains electricity

If you see the no mains power icon        this means that the thermostat is not receiving 

power. Check that the thermostat logic module is properly installed on the power 

module and that the mains electricity supply is connected. 

Regulator mode (Reg) is displayed

In this mode your thermostat will come on for a set number of minutes in a 10 minute 

cycle. The thermostat will not use the temperature for control. Please contact Warmup 

for additional details. 

HI or LO is displayed 

The thermostat will display “HI” if the ambient temperature exceeds 122°F (50°C) and 

“LO” when the ambient temperature falls below 32°F (0°C).

Maximum Overheat Limits

Tiles

40°C / 104°F

Stone

40°C / 104°F

Wood / Laminate

28°C / 86°F

Carpet 

28°C / 86°F

Vinyl 

28°C / 86°F

Error messages / Trouble shooting 

Summary of Contents for Tempo

Page 1: ...erence received including interference that may cause undesired opera tion Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the u...

Page 2: ...f thermostat 2 Unscrew both closing screws at the bottom until they don t turn any further 3 Release front housing by gripping lower half of outer frame and pulling outwards then upwards Place front h...

Page 3: ...ill show whether the thermostat is at Comfort or Setback temperature The icon will be displayed when Comfort 1 2 is the target temperature Only used with the Fil Pilote 3 This icon is displayed when t...

Page 4: ...wer Battery is low Getting started In order to program the Tempo thermostat all you need to do is slide the Program Slide control from the top position to the bottom position customising the program a...

Page 5: ...he next day If you hold the Main Button for 3 seconds it will copy the start time to the next day Tip If you want to set the thermostat so that it is keeping the comfort temperature all day and only s...

Page 6: ...t the installer setting mode Installer Step Setting Configured Default Value LCD Example 1 Change clock format 12hr 24hr 12 2 Change unit of measurement Degree C F F 3 Change sensor used to target tem...

Page 7: ...r is lost Heating starts too early If your heating is coming on too early then this may be because the Adaptive Learning function is turned on This function allows your thermostat to learn how long it...

Page 8: ...sole responsibility shall be to repair or replace the product within the terms stated above WARMUP SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMA...

Reviews: