14
Display is blank
(Electrician Required)
Electrician required to verify power is
going to the thermostat and that it is correctly wired.
The thermostat is
not controlling the
temperature
Ensure that the program slider is in the run position ”
1
2
3
4
”
(lowest point) and that the mode slider control (bottom) is in
the manual “ “ or program “ “positions.
Heating is coming
on earlier than
programmed times
Adaptive learning calculates the optimum heating start time
in order to reach the comfort temperature at the start of
the comfort period. It will only work in Program Mode. See
installer setting #5.
Floor sensor error
“
1
2
3
4
” / “
---
”
(Electrician Required)
Electrician required to verify that the
floor sensor has been wired correctly. If it is correctly wired
the electrician will need to check the resistance of the floor
sensor using a multi-meter. For temperatures between 20°C
- 30°C the resistance of the floor sensor should measure
between 8K ohms and 12K ohms.
If the electrician finds a fault, and the thermostat is in the
room to be heated then it can be set into “Air Mode”.
To set into “Air Mode” or “Regulator Mode”, see installer
setting #3.
If “
---
” still remains when set into air mode the thermostat
will have to be replaced.
Overheat “
“
If you see the overheat icon this means that your floor has
become too hot and the heating has been suspended. See
installer setting #7.
Low battery “
1
2
3
4
”
The low battery icon will display when the coil-cell CR2032
3-volt lithium battery needs to be replaced. The thermostat
must be connected to the mains electricity supply in order
to work, it is not designed to be used with an intermittent
power supply. If the battery is not installed then your
thermostat will not be able to maintain the clock time if
power is lost.
Incorrect calibration
Your thermostat should not need any calibration, however if
you would like to apply an offset to the temperature settings
see the installer setting #8.
No mains electricity
“
1
2
3
4
”
(Electrician Required)
The thermostat is not receiving
power. Check the thermostat power module is properly
installed and that there is 230V mains electricity supply
connected.
Regulator mode (Reg)
is displayed
In this mode your thermostat will come on for a set number
of minutes in a 10 minute cycle. The thermostat will not use
the temperature for control.
Fil Pilote (FP) is
displayed
The thermostat can obey the 6 standard commands of fil
pilote (pilote wire), (France only).
HI or LO is displayed
The thermostat will display “HI” if the ambient temperature
exceeds 40°C (104°F) and “LO” when the ambient
temperature falls below 0°C (32°F).
Troubleshooting
Summary of Contents for tempo ELT-01-XX-01